Literature DB >> 11573920

Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel.

J B Selby1, D L Johnson, P Hester, D N Caborn.   

Abstract

Initial tibial fixation strength is the weak link after anterior cruciate ligament reconstruction with a quadrupled hamstring tendon graft fixed with bioabsorbable interference screws. The purpose of this study was to determine the biomechanical differences between 28-mm and tapered 35-mm interference screws for tibial fixation of a soft tissue graft in 16 young cadaveric tibias. Failure mode, displacement before failure, and ultimate failure load were tested with a testing machine aligned with the tibial tunnel to simulate a worst-case scenario. The mode of failure was graft slippage past the screw in all but one of the specimens. The mean maximum load at failure of the 28-mm screw was 594.9 +/- 141.0 N, with mean displacement at failure of 10.97 +/- 2.20 mm. The mean maximum load at failure of the 35-mm screw was 824.9 +/- 124.3 N, with a mean displacement to failure of 14.38 +/- 2.15 mm. The 38% difference in mean maximal load at failure was significant. Important variables in hamstring tendon graft fixation within a bone tunnel include bone mineral density, dilatation, gap size, screw placement, and screw width and length. Attention to these variables will help to provide secure graft fixation during biologic incorporation throughout the rehabilitation period.

Entities:  

Mesh:

Year:  2001        PMID: 11573920     DOI: 10.1177/03635465010290051401

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  12 in total

1.  Optimal screw diameter for interference fixation in a bone tunnel: a porcine model.

Authors:  M W J Morris; J L Williams; A J Thake; Y Lang; J N Brown
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-02-06       Impact factor: 4.342

2.  Comparison of volumetric bone mineral density in the tibial region of interest for ACL reconstruction.

Authors:  Scott A Klein; John Nyland; David N M Caborn; Yavuz Kocabey; Akbar Nawab
Journal:  Surg Radiol Anat       Date:  2005-10-20       Impact factor: 1.246

Review 3.  Graft choice and graft fixation in PCL reconstruction.

Authors:  Jürgen Höher; Sven Scheffler; Andreas Weiler
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-08-26       Impact factor: 4.342

4.  Failure load of patellar tendon grafts at the femoral side: 10- versus 20-mm-bone blocks.

Authors:  Duncan E Meuffels; Marnix J N Niggebrugge; Jan A N Verhaar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-07       Impact factor: 4.342

Review 5.  Graft fixation alternatives in anterior cruciate ligament reconstruction.

Authors:  Bernardino Saccomanni
Journal:  Musculoskelet Surg       Date:  2011-05-03

6.  A biomechanical comparison of the Delta screw and RetroScrew tibial fixation on initial intra-articular graft tension.

Authors:  Peter C Rhee; Bruce A Levy; Michael J Stuart; Andrew Thoreson; Kai-Nan An; Diane L Dahm
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-22       Impact factor: 4.342

7.  Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study.

Authors:  Antonio Herrera; Fernando Martínez; Daniel Iglesias; José Cegoñino; Elena Ibarz; Luis Gracia
Journal:  BMC Musculoskelet Disord       Date:  2010-06-30       Impact factor: 2.362

8.  Mechanical evaluation of a soft tissue interference screw with a small diameter: significance of graft/bone tunnel cross-sectional area ratio.

Authors:  Akio Matsumoto; Shinichi Yoshiya; Hirotsugu Muratsu; Nobuzo Matsui; Masayoshi Yagi; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-09-15       Impact factor: 4.342

9.  Tibial fixation comparison of semitendinosus-bone composite allografts fixed with bioabsorbable screws and bone-patella tendon-bone grafts fixed with titanium screws.

Authors:  Y Kocabey; S Klein; J Nyland; D Caborn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-07-04       Impact factor: 4.342

10.  Influence of hydroxyapatite-coated and growth factor-releasing interference screws on tendon-bone healing in an ovine model.

Authors:  Yan Lu; Mark D Markel; Brett Nemke; J Sam Lee; Ben K Graf; William L Murphy
Journal:  Arthroscopy       Date:  2009-11-06       Impact factor: 4.772

View more