Literature DB >> 11560838

High resolution CISS imaging of the spine.

N Ramli1, A Cooper, T Jaspan.   

Abstract

Spatial resolution remains one of the major problems and goals in spinal imaging. The high spatial resolution afforded by a novel sequence, constructive interference in steady state (CISS), provides a further refinement to MRI, the modality of choice in the investigation of suspected intraspinal pathology. Both complex and subtle abnormalities are more fully elucidated using CISS. It is now used in our institution as an adjunct to conventional imaging sequences in the diagnostic evaluation of complex intraspinal pathology. The anatomical information provided by CISS is of particular value in planning surgical interventions, most notably in the management of intraaxial and extraaxial cystic abnormalities, dysraphic malformations and disturbances of cerebrospinal fluid circulation, including post-traumatic and post-surgical scarring.

Entities:  

Mesh:

Year:  2001        PMID: 11560838     DOI: 10.1259/bjr.74.885.740862

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  18 in total

Review 1.  Review of the principal extra spinal pathologies causing sciatica and new MRI approaches.

Authors:  A Ailianou; A Fitsiori; A Syrogiannopoulou; S Toso; M Viallon; L Merlini; J Y Beaulieu; M I Vargas
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

2.  Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences.

Authors:  T Meindl; S Wirth; S Weckbach; O Dietrich; M Reiser; S O Schoenberg
Journal:  Eur Radiol       Date:  2008-09-24       Impact factor: 5.315

3.  Three dimensional MRI study: Safety of short versus long needle peribulbar anesthesia.

Authors:  Sahar M ElKhamary; Waleed Riad
Journal:  Saudi J Ophthalmol       Date:  2014-03-19

4.  MRI of the lumbar spine at 7 Tesla in healthy volunteers and a patient with congenital malformations.

Authors:  Astrid E Grams; Oliver Kraff; Lale Umutlu; Stefan Maderwald; Philipp Dammann; Mark E Ladd; Michael Forsting; Elke R Gizewski
Journal:  Skeletal Radiol       Date:  2011-05-24       Impact factor: 2.199

5.  Dynamic morphological changes in lumbosacral lipoma during the first months of life revealed by constructive interference in steady-state (CISS) MR imaging.

Authors:  Takato Morioka; Kimiaki Hashiguchi; Fumiaki Yoshida; Shinji Nagata; Yasushi Miyagi; Futoshi Mihara; Tomio Sasaki
Journal:  Childs Nerv Syst       Date:  2006-12-23       Impact factor: 1.475

6.  Neonatal post-hemorrhagic hydrocephalus resulting in foraminal septae-radiological technique and surgical implications.

Authors:  Farhana Fadzli; Norlisah Mohamad Ramli; Kartini Rahmat; Dharmendra Ganesan
Journal:  Childs Nerv Syst       Date:  2012-09-21       Impact factor: 1.475

7.  Feasibility and limitation of constructive interference in steady-state (CISS) MR imaging in neonates with lumbosacral myeloschisis.

Authors:  Kimiaki Hashiguchi; Takato Morioka; Fumiaki Yoshida; Yasushi Miyagi; Futoshi Mihara; Takashi Yoshiura; Shinji Nagata; Tomio Sasaki
Journal:  Neuroradiology       Date:  2007-03-31       Impact factor: 2.804

8.  Usefulness of three-dimensional T1-weighted spoiled gradient-recalled echo and three-dimensional heavily T2-weighted images in preoperative evaluation of spinal dysraphism.

Authors:  Nobuya Murakami; Takato Morioka; Kimiaki Hashiguchi; Takashi Yoshiura; Akio Hiwatashi; Satoshi O Suzuki; Akira Nakamizo; Toshiyuki Amano; Nobuhiro Hata; Tomio Sasaki
Journal:  Childs Nerv Syst       Date:  2013-05-15       Impact factor: 1.475

9.  Rapid semi-automatic segmentation of the spinal cord from magnetic resonance images: application in multiple sclerosis.

Authors:  Mark A Horsfield; Stefania Sala; Mohit Neema; Martina Absinta; Anshika Bakshi; Maria Pia Sormani; Maria A Rocca; Rohit Bakshi; Massimo Filippi
Journal:  Neuroimage       Date:  2010-01-07       Impact factor: 6.556

10.  Balanced Steady-State Free Precession Sequence (CISS/FIESTA/3D Driven Equilibrium Radiofrequency Reset Pulse) Increases the Diagnostic Yield for Spinal Drop Metastases in Children with Brain Tumors.

Authors:  K Buch; P Caruso; D Ebb; S Rincon
Journal:  AJNR Am J Neuroradiol       Date:  2018-05-17       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.