Computer and experimental simulation of a cortical end-plate phase cancellation artefact in the measurement of BUA at the calcaneus.

C M Langton1, M Subhan.   

Abstract

It has been experimentally demonstrated that for the measurement of broadband ultrasound attenuation (BUA) at the human calcaneus the cortical end-plate creates a measurement artefact of the order of 7 dB MHz(-1). It has been suggested that the origin of this artefact may be a phase cancellation of the ultrasound pulse resulting from inconsistencies in propagation time across the ultrasound beam. Experimental and computer simulations were performed on samples of varying degrees of curvature and hence varying propagation times across the ultrasound beam. The experimental simulation incorporated Perspex samples of 35, 50 and 75 mm radius. The computer simulation was implemented using Matlab and Simulink, with the propagation time represented by a transport delay. The wavelet-based simulation incorporated a digitized transmitted ultrasound pulse derived from the experimental simulation. The experimental and computer-derived frequency spectra for the varying radii samples were comparable, demonstrating, firstly, that there is a significant dependence of measured BUA upon radius of curvature and, secondly, that the response in measured BUA to radius of curvature is similar in magnitude and trend for both experimental and computer simulations. The current study suggests that the BUA artefact observed in vitro corresponds to a radius of approximately 58 mm. Although the radius of curvature was not recorded in the original in vitro study, this value appears to be reasonable. This study indicates that the assumptions within the computer simulation were manifested within the experimental validation, and, hence, the observed BUA measurement artefact is related to the presence of the calcaneal cortical end-plate and is due to phase cancellation of the propagating ultrasound pulse.

Entities:  

Mesh:

Year:  2001        PMID: 11556676     DOI: 10.1088/0967-3334/22/3/314

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  8 in total

1.  Conventional, Bayesian, and Modified Prony's methods for characterizing fast and slow waves in equine cancellous bone.

Authors:  Amber M Groopman; Jonathan I Katz; Mark R Holland; Fuminori Fujita; Mami Matsukawa; Katsunori Mizuno; Keith A Wear; James G Miller
Journal:  J Acoust Soc Am       Date:  2015-08       Impact factor: 1.840

2.  The effect of phase cancellation on estimates of broadband ultrasound attenuation and backscatter coefficient in human calcaneus in vitro.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-02       Impact factor: 2.725

3.  The effect of phase cancellation on estimates of calcaneal broadband ultrasound attenuation in vivo.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-07       Impact factor: 2.725

4.  Bone sonometry: reducing phase aberration to improve estimates of broadband ultrasonic attenuation.

Authors:  Adam Q Bauer; Christian C Anderson; Mark R Holland; James G Miller
Journal:  J Acoust Soc Am       Date:  2009-01       Impact factor: 1.840

5.  Time-domain separation of interfering waves in cancellous bone using bandlimited deconvolution: simulation and phantom study.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2014-04       Impact factor: 1.840

6.  Effects of phase cancellation and receiver aperture size on broadband ultrasonic attenuation for trabecular bone in vitro.

Authors:  Jiqi Cheng; Frederick Serra-Hsu; Yuan Tian; Wei Lin; Yi-Xian Qin
Journal:  Ultrasound Med Biol       Date:  2011-10-26       Impact factor: 2.998

7.  Effect of the cortex on ultrasonic backscatter measurements of cancellous bone.

Authors:  Brent K Hoffmeister; Andrew P Holt; Sue C Kaste
Journal:  Phys Med Biol       Date:  2011-09-06       Impact factor: 3.609

8.  Quantitative ultrasound imaging monitoring progressive disuse osteopenia and mechanical stimulation mitigation in calcaneus region through a 90-day bed rest human study.

Authors:  Yi-Xian Qin; Yi Xia; Jesse Muir; Wei Lin; Clinton T Rubin
Journal:  J Orthop Translat       Date:  2018-12-24       Impact factor: 5.191

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.