Literature DB >> 11535472

Anterior capsule opacification: correlation of pathologic findings with clinical sequelae.

L Werner1, S K Pandey, D J Apple, M Escobar-Gomez, L McLendon, T A Macky.   

Abstract

OBJECTIVE: To evaluate the degree of anterior capsule opacification (ACO) in human eyes obtained postmortem containing various rigid and foldable posterior chamber intraocular lens (PC-IOL) designs and compare the findings with clinical sequelae of capsular shrinkage.
DESIGN: Comparative autopsy tissue study with clinicopathologic correlations. MATERIALS: Three hundred formalin-fixed human eyes containing the following PC-IOL styles were analyzed: (1) one-piece polymethyl methacrylate (PMMA) optic-PMMA haptic (n = 50), one-piece silicone-plate IOL, with large (2) or small (3) fixation holes (n = 35), (4) three-piece PMMA optic-Prolene haptic (n = 50), (5) three-piece acrylic optic-PMMA haptic (n = 55), three-piece silicone optic with PMMA (6) or polyimide (7) haptics (n = 30), and (8) three-piece silicone optic-Prolene haptic (n = 80) lenses. TESTING: The eyes were sectioned in the equatorial plane for gross examination of the capsular bag from a posterior view. The cornea and iris were then excised for evaluation from an anterior view. MAIN OUTCOME MEASURES: ACO was scored in each eye from 0 to IV, according to the degree/area of capsule opacification. Capsulorrhexis size and IOL decentration were measured with calipers.
RESULTS: The overall differences among the IOL groups regarding the three parameters were significant (ACO score: P < 0.001; capsulorrhexis diameter: P = 0.036; IOL decentration: P = 0.012). Mean ACO scores were highest with the large- and small-hole one-piece silicone-plate lenses (2.543 +/- 0.950) and lowest with the three-piece acrylic optic-PMMA haptic lenses (0.600 +/- 0.710). Of 10 cases of capsulorrhexis phimosis observed in the study, 7 cases were associated with three-piece silicone optic-Prolene haptic lenses, which also presented the highest mean decentration (0.375 +/- 0.601 mm).
CONCLUSIONS: Our results confirm previous histopathologic observations that the rate of ACO is the lowest with acrylic lenses and higher with plate-haptic silicone IOLs. Nevertheless, clinical sequelae of capsular shrinkage are also very important with three-piece silicone optic-Prolene haptic designs. Thus, IOL material and design are significant factors in the development of ACO, but they ultimately also influence the clinical presentation of capsular shrinkage.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11535472     DOI: 10.1016/s0161-6420(01)00674-1

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  24 in total

1.  The "demise" of diagnostic and research ocular pathology: temporary or forever?

Authors:  David J Apple; Liliana Werner; Nick Mamalis; Randall J Olson
Journal:  Trans Am Ophthalmol Soc       Date:  2003

2.  Capsular contraction syndrome following insertion of hydrophilic acrylic lens.

Authors:  Archana Malik; Neeti Gupta; Sunandan Sood
Journal:  Int Ophthalmol       Date:  2011-01-29       Impact factor: 2.031

3.  Circular YAG laser anterior capsulotomy for anterior capsule contraction syndrome.

Authors:  Mohamed Nagy Elmohamady; Ashraf Elhabbak; Elham Abdelazim Gad
Journal:  Int Ophthalmol       Date:  2019-03-11       Impact factor: 2.031

4.  Anterior and posterior capsule densitometry levels after femtosecond laser-assisted cataract surgery.

Authors:  Txomin Alberdi; Javier Mendicute; Lucía Bascarán; Olatz Barandika; Javier Ruiz-Ederra
Journal:  Int J Ophthalmol       Date:  2018-04-18       Impact factor: 1.779

5.  A prospective evaluation of posterior capsule opacification in eyes with diabetes mellitus: a case-control study.

Authors:  M R Praveen; A R Vasavada; G D Shah; A R Shah; B M Khamar; K H Dave
Journal:  Eye (Lond)       Date:  2014-03-28       Impact factor: 3.775

6.  Effect of the hydrophilicity of acrylic intraocular lens material and haptic angulation on anterior capsule opacification.

Authors:  Lorenz Vock; Michael Georgopoulos; Thomas Neumayer; Wolf Buehl; Oliver Findl
Journal:  Br J Ophthalmol       Date:  2006-11-15       Impact factor: 4.638

7.  Myo/Nog cells are present in the ciliary processes, on the zonule of Zinn and posterior capsule of the lens following cataract surgery.

Authors:  Jacquelyn Gerhart; Colleen Withers; Colby Gerhart; Liliana Werner; Nick Mamalis; Arturo Bravo-Nuevo; Victoria Scheinfeld; Paul FitzGerald; Robert Getts; Mindy George-Weinstein
Journal:  Exp Eye Res       Date:  2018-03-17       Impact factor: 3.467

8.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

9.  Adherence and viability of porcine lens epithelial cells on three different IOL materials in vitro.

Authors:  Yvonne Hesse; Jürgen Kampmeier; Gerhard K Lang; Alicia Baldysiak-Figiel; Gabriele E Lang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-08-23       Impact factor: 3.117

10.  The impact of capsulorhexis diameter, localization and shape on posterior capsule opacification.

Authors:  Ewa Langwińska-Wośko; Karina Broniek-Kowalik; Kamil Szulborski
Journal:  Med Sci Monit       Date:  2011-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.