A study of bispectral analysis and auditory evoked potential indices during propofol-induced hypnosis in volunteers: the effect of an episode of wakefulness on explicit and implicit memory.

G Barr1, R E Anderson, J G Jakobsson.   

Abstract

The bispectral index (BIS) and the auditory evoked potential (AEP) index as calculated by the new A-line monitor were measured during hypnosis with propofol, which included an episode of wakefulness. Both indices followed a similar pattern during sedation, with values decreasing with sedation and increasing when awake. Baseline AEP values varied between 60 and 98, and BIS values were between 96 and 98. The AEP-index value was at all times 10-20 points lower than the BIS-index. The transition to loss of response occurred at a mean AEP value of 46 and BIS value of 58. The transition to just responding following a period of unconsciousness occurred at a mean AEP value of 46 and BIS 65. Both monitoring techniques, however, displayed large interindividual variations making it impossible to discriminate in real time between subtle changes of clinical state. The new neurophysiological monitors A-line AEP and BIS are interesting tools for creating a better understanding of the anaesthetic effects of drugs; however, further refinements are required before their relative roles can be fully established in the clinical setting.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11531678     DOI: 10.1046/j.1365-2044.2001.02059-3.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  6 in total

1.  Facilitated assessment of unconsciousness from morphologic changes in the bilateral posterior tibial nerve cortical somatosensory evoked potential under total intravenous propofol anesthesia during spine surgery.

Authors:  Daniel M Schwartz; Anthony K Sestokas
Journal:  J Clin Monit Comput       Date:  2004-06       Impact factor: 2.502

2.  Comparison of the EEG-based SNAP index and the Bispectral (BIS) index during sevoflurane-nitrous oxide anaesthesia.

Authors:  P Ruiz-Gimeno; M Soro; A Pérez-Solaz; M Carrau; F J Belda; J L Jover; G Aguilar
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

3.  Effects of A-line Autoregression Index (AAI) monitoring on recovery after sevoflurane anesthesia for bariatric surgery.

Authors:  Ulderico Freo; Michele Carron; Federico Innocente; Mirto Foletto; Donato Nitti; Carlo Ori
Journal:  Obes Surg       Date:  2011-07       Impact factor: 4.129

4.  Auditory evoked potentials index versus bispectral index during propofol sedation in spinal anesthesia.

Authors:  Tomoki Nishiyama
Journal:  J Anesth       Date:  2009-02-22       Impact factor: 2.078

5.  Correlation beween AAI-index and the BIS-index during propofol hypnosis: a clinical study.

Authors:  Russell E Anderson; Gunilla Barr; Jan G Jakobsson
Journal:  J Clin Monit Comput       Date:  2002-08       Impact factor: 2.502

Review 6.  Physiologic Measures of Animal Stress during Transitional States of Consciousness.

Authors:  Robert E Meyer
Journal:  Animals (Basel)       Date:  2015-08-07       Impact factor: 2.752

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.