Literature DB >> 11527947

Long-term fluctuation in short-wavelength automated perimetry in glaucoma suspects and glaucoma patients.

N Hutchings1, S L Hosking, J M Wild, J G Flanagan.   

Abstract

PURPOSE: To determine the magnitude of the homogeneous, LF(Ho), and the heterogeneous, LF(He), components of the long-term fluctuation (LF) in glaucoma suspects and in stable primary open angle glaucoma (POAG) patients undergoing short-wavelength automated perimetry (SWAP) and to compare the magnitude of the SWAP LF components with those elicited by standard white-on-white (W-W) perimetry.
METHODS: The sample comprised 33 glaucoma suspects and 17 patients with early-to-moderate stable POAG who underwent W-W perimetry and SWAP at each of six visits over a mean period of 12.75 months (SD, 2.29). The LF(Ho), LF(He), and error components of the long-term fluctuation were determined between the third and seventh visual field examinations. The intervening visual field examinations and the optic nerve head parameters, derived both by stereo observation and by the Heidelberg Retinal Tomograph, were used to confirm stability over the follow-up period.
RESULTS: The LF(Ho) and LF(He) components were larger in the POAG patients than in the glaucoma suspects for both W-W perimetry and SWAP; the magnitude was independent of the depth of defect and of the short-term fluctuation. All three components of long-term fluctuation were greater for SWAP than for W-W perimetry, both in the glaucoma suspects and in the POAG patients.
CONCLUSIONS: SWAP exhibits greater long-term fluctuation than white-on-white perimetry. The usefulness of SWAP will be limited if the extent of this variability is not overcome in future statistical procedures developed to detect progressive visual field loss.

Entities:  

Mesh:

Year:  2001        PMID: 11527947

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  6 in total

1.  Detecting ocular-visual function changes in diabetes.

Authors:  C A Westall
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

2.  Simultaneous recording of multifocal VEP responses to short-wavelength and achromatic stimuli.

Authors:  Xian Zhang; Min Wang; Donald C Hood
Journal:  Doc Ophthalmol       Date:  2010-05-25       Impact factor: 2.379

3.  Frequency of seeing characteristics of the short wavelength sensitive visual pathway in clinically normal subjects and diabetic patients with focal sensitivity loss.

Authors:  E D Gilmore; C Hudson; R K Nrusimhadevara; P T Harvey
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

4.  Is there evidence for continued learning over multiple years in perimetry?

Authors:  Stuart K Gardiner; Shaban Demirel; Chris A Johnson
Journal:  Optom Vis Sci       Date:  2008-11       Impact factor: 1.973

5.  Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects.

Authors:  Chintan Malhotra
Journal:  Oman J Ophthalmol       Date:  2009-01

6.  Comparison of SWAP and SAP on the point of glaucoma conversion.

Authors:  Ioannis Havvas; Dimitris Papaconstantinou; Marilita M Moschos; Panagiotis G Theodossiadis; Vasilios Andreanos; Pantelis Ekatomatis; Ioannis Vergados; Dimitrios Andreanos
Journal:  Clin Ophthalmol       Date:  2013-09-19
  6 in total