Literature DB >> 11524335

Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest.

K G Lurie1, W G Voelckel, T Zielinski, S McKnite, P Lindstrom, C Peterson, V Wenzel, K H Lindner, N Samniah, D Benditt.   

Abstract

To improve the efficiency of standard cardiopulmonary resuscitation (CPR), we evaluated the potential value of impeding respiratory gas exchange selectively during the decompression phase of standard CPR in a porcine model of ventricular fibrillation. After 6 min of untreated cardiac arrest, anesthetized farm pigs weighing 30 kg were randomized to be treated with either standard CPR with a sham valve (n = 11) or standard CPR plus a functional inspiratory impedance threshold valve (ITV(TM)) (n = 11). Coronary perfusion pressure (CPP) (diastolic aortic minus right atrial pressure) was the primary endpoint. Vital organ blood flow was assessed with radiolabeled microspheres after 6 min of CPR, and defibrillation was attempted 11 min after starting CPR. After 2 min of CPR, mean +/- SEM CPP was 14 +/- 2 mm Hg with the sham valve versus 20 +/- 2 mm Hg in the ITV group (P < 0.006). Significantly higher CPPs were maintained throughout the study when the ITV was used. After 6 min of CPR, mean +/- SEM left ventricular and global cerebral blood flows were 0.10 +/- 0.03 and 0.19 +/- 0.03 mL. min(-1). g(-1) in the Control group versus 0.19 +/- 0.03 and 0.26 +/- 0.03 mL. min(-1). g(-1) in the ITV group, respectively (P < 0.05). Fifteen minutes after successful defibrillation, 2 of 11 animals were alive in the Control group versus 6 of 11 in the ITV group (not significant). In conclusion, use of an inspiratory impedance valve during standard CPR resulted in a marked increase in CPP and vital organ blood flow after 6 min of cardiac arrest.

Entities:  

Mesh:

Year:  2001        PMID: 11524335     DOI: 10.1097/00000539-200109000-00024

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  14 in total

1.  Use of the impedance threshold device in cardiopulmonary resuscitation.

Authors:  Theano D Demestiha; Ioannis N Pantazopoulos; Theodoros T Xanthos
Journal:  World J Cardiol       Date:  2010-02-26

2.  Effects of inspiratory impedance on hemodynamic responses to a squat-stand test in human volunteers: implications for treatment of orthostatic hypotension.

Authors:  Victor A Convertino; Duane A Ratliff; Jacqueline Crissey; Donald F Doerr; Ahamed H Idris; Keith G Lurie
Journal:  Eur J Appl Physiol       Date:  2005-04-28       Impact factor: 3.078

Review 3.  [The new 2005 resuscitation guidelines of the European Resuscitation Council: comments and supplements].

Authors:  V Wenzel; S Russo; H R Arntz; J Bahr; M A Baubin; B W Böttiger; B Dirks; V Dörges; C Eich; M Fischer; B Wolcke; S Schwab; W G Voelckel; H W Gervais
Journal:  Anaesthesist       Date:  2006-09       Impact factor: 1.041

4.  [Comments on the 2010 guidelines on cardiopulmonary resuscitation of the European Resuscitation Council].

Authors:  V Wenzel; S G Russo; H R Arntz; J Bahr; M A Baubin; B W Böttiger; B Dirks; U Kreimeier; M Fries; C Eich
Journal:  Anaesthesist       Date:  2010-12       Impact factor: 1.041

5.  Sodium nitroprusside enhanced cardiopulmonary resuscitation (SNPeCPR) improves vital organ perfusion pressures and carotid blood flow in a porcine model of cardiac arrest.

Authors:  Jason Schultz; Nicolas Segal; James Kolbeck; Scott McKnite; Emily Caldwell; Demetris Yannopoulos
Journal:  Resuscitation       Date:  2011-08-22       Impact factor: 5.262

6.  Improved cerebral perfusion pressures and 24-hr neurological survival in a porcine model of cardiac arrest with active compression-decompression cardiopulmonary resuscitation and augmentation of negative intrathoracic pressure.

Authors:  Anja K Metzger; Margot Herman; Scott McKnite; Wanchun Tang; Demetris Yannopoulos
Journal:  Crit Care Med       Date:  2012-06       Impact factor: 7.598

7.  New Developments in Cardiac Arrest Management.

Authors:  Matthias L Riess
Journal:  Adv Anesth       Date:  2016

8.  Resuscitation Outcomes Consortium (ROC) PRIMED cardiac arrest trial methods part 1: rationale and methodology for the impedance threshold device (ITD) protocol.

Authors:  Tom P Aufderheide; Peter J Kudenchuk; Jerris R Hedges; Graham Nichol; Richard E Kerber; Paul Dorian; Daniel P Davis; Ahamed H Idris; Clifton W Callaway; Scott Emerson; Ian G Stiell; Thomas E Terndrup
Journal:  Resuscitation       Date:  2008-05-19       Impact factor: 5.262

9.  Chest Compression Synchronized Ventilation versus Intermitted Positive Pressure Ventilation during Cardiopulmonary Resuscitation in a Pig Model.

Authors:  Clemens Kill; Monika Galbas; Christian Neuhaus; Oliver Hahn; Pascal Wallot; Karl Kesper; Hinnerk Wulf; Wolfgang Dersch
Journal:  PLoS One       Date:  2015-05-26       Impact factor: 3.240

10.  Effects of mechanical ventilation with expiratory negative airway pressure on porcine pulmonary and systemic circulation: mechano-physiology and potential application.

Authors:  Mihoko Hagiwara-Nagasawa; Ryuichi Kambayashi; Ai Goto; Koki Chiba; Takeshi Wada; Yoshio Nunoi; Hiroko Izumi-Nakaseko; Yoshinori Takei; Akio Matsumoto; Keith G Lurie; Atsushi Sugiyama
Journal:  J Physiol Sci       Date:  2021-06-02       Impact factor: 2.781

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.