Literature DB >> 11523739

Numerical simulations of unsteady flows in a stenosed coronary bypass graft.

V Deplano1, C Bertolotti, O Boiron.   

Abstract

Using the finite element method, physiological blood flows through a three-dimensional model of a coronary graft are numerically analysed. The model includes a stenosis shape in the host artery upstream from the anastomosis. Recirculating areas, secondary flows, wall shear stress (WSS) and spatial wall shear stress gradients (WSSGs) are studied for different flow repartitions and at different times in the cycle. The temporal and spatial evolutions of the recirculating areas downstream from the stenosis, their interactions with the flow issued from the graft and their associated WSSs highlight that the presence of the stenosis in the recipient artery is essential for prediction of the evolution of a grafting at the beginning of its implantation. The areas downstream from the stenosis expansion, non-existent for a host artery without stenosis, are submitted to low and oscillating WSS between -0.5 and 0 Nm(-2). The stagnation point on the recipient artery floor is subjected to high positive and negative WSSGnd values, and its location is dependent on the residual flow through the stenosis.

Entities:  

Mesh:

Year:  2001        PMID: 11523739     DOI: 10.1007/BF02345372

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   3.079


  22 in total

1.  Relation between non-uniform hemodynamics and sites of altered permeability and lesion growth at the rabbit aorto-celiac junction.

Authors:  J R Buchanan; C Kleinstreuer; G A Truskey; M Lei
Journal:  Atherosclerosis       Date:  1999-03       Impact factor: 5.162

Review 2.  Biofluid dynamics at arterial bifurcations.

Authors:  Z Lou; W J Yang
Journal:  Crit Rev Biomed Eng       Date:  1992

3.  Numerical analysis of steady flow in aorto-coronary bypass 3-D model.

Authors:  F Inzoli; F Migliavacca; G Pennati
Journal:  J Biomech Eng       Date:  1996-05       Impact factor: 2.097

4.  Numerical investigation of steady flow in proximal and distal end-to-side anastomoses.

Authors:  F S Henry; M W Collins; P E Hughes; T V How
Journal:  J Biomech Eng       Date:  1996-08       Impact factor: 2.097

5.  Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress.

Authors:  D N Ku; D P Giddens; C K Zarins; S Glagov
Journal:  Arteriosclerosis       Date:  1985 May-Jun

6.  Flow disturbance at the distal end-to-side anastomosis. Effect of patency of the proximal outflow segment and angle of anastomosis.

Authors:  H M Crawshaw; W C Quist; E Serallach; C R Valeri; F W LoGerfo
Journal:  Arch Surg       Date:  1980-11

Review 7.  Vascular fluid mechanics, the arterial wall, and atherosclerosis.

Authors:  R M Nerem
Journal:  J Biomech Eng       Date:  1992-08       Impact factor: 2.097

8.  Influence of arterial damage and wall shear rate on platelet deposition. Ex vivo study in a swine model.

Authors:  L Badimon; J J Badimon; A Galvez; J H Chesebro; V Fuster
Journal:  Arteriosclerosis       Date:  1986 May-Jun

9.  Pulsatile velocity measurements in a model of the human abdominal aorta under resting conditions.

Authors:  J E Moore; D N Ku
Journal:  J Biomech Eng       Date:  1994-08       Impact factor: 2.097

10.  Numerical investigation and prediction of atherogenic sites in branching arteries.

Authors:  M Lei; C Kleinstreuer; G A Truskey
Journal:  J Biomech Eng       Date:  1995-08       Impact factor: 2.097

View more
  6 in total

1.  Numerical simulation of unsteady micropolar hemodynamics in a tapered catheterized artery with a combination of stenosis and aneurysm.

Authors:  Akbar Zaman; Nasir Ali; O Anwar Bég
Journal:  Med Biol Eng Comput       Date:  2015-11-05       Impact factor: 2.602

2.  Numerical Simulation of Physiological Blood Flow in 2-way Coronary Artery Bypass Grafts.

Authors:  Aike Qiao; Youjun Liu; Siyang Li; Hu Zhao
Journal:  J Biol Phys       Date:  2005-05       Impact factor: 1.365

3.  Comparison of in vitro human endothelial cell response to self-expanding stent deployment in a straight and curved peripheral artery simulator.

Authors:  Ríona Ní Ghriallais; Laoise McNamara; Mark Bruzzi
Journal:  J R Soc Interface       Date:  2013-01-30       Impact factor: 4.118

4.  A generalised porous medium approach to study thermo-fluid dynamics in human eyes.

Authors:  Alessandro Mauro; Nicola Massarotti; Mohamed Salahudeen; Mario R Romano; Vito Romano; Perumal Nithiarasu
Journal:  Med Biol Eng Comput       Date:  2018-03-22       Impact factor: 2.602

Review 5.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

6.  Non-Invasive Quantification of Fraction Flow Reserve Based on Steady-State Geometric Multiscale Models.

Authors:  Jincheng Liu; Xue Wang; Bao Li; Suqin Huang; Hao Sun; Liyuan Zhang; Yutong Sun; Zhuo Liu; Jian Liu; Lihua Wang; Xi Zhao; Wenxin Wang; Mingzi Zhang; Youjun Liu
Journal:  Front Physiol       Date:  2022-04-12       Impact factor: 4.755

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.