Literature DB >> 7799637

Pulsatile velocity measurements in a model of the human abdominal aorta under resting conditions.

J E Moore1, D N Ku.   

Abstract

Oscillations in near-wall velocity direction have been found to correlate with atherosclerotic plaque localization in the carotid sinus bifurcation. However, it remains unproven whether these conditions could account for the localization of the disease at other sites where atherosclerosis forms. The abdominal aorta is an important site of clinical disease in a relatively straight segment of artery. This study was initiated to quantify the velocity field in the abdominal aorta in order to determine if local differences in hemodynamic velocity directions could account for the localization of disease in this segment. Magnetic Resonance Imaging velocimetry was used to measure the pulsatile velocity profiles in an anatomically accurate in vitro model of the abdominal aorta. Velocities measured in the suprarenal aorta were laminar and reversed minimally, comparing well with theoretical solutions of Womersley flow (r = 0.96). The time-averaged velocity was +3.0 cm/s near-wall at a distance of 1 mm away from the wall. In the infrarenal aorta, the maximal velocities were skewed toward the anterior wall. At the posterior wall, velocity oscillated in direction and was retrograde for 82 percent of the cardiac cycle. The time-averaged velocity near the posterior wall was -12.5 cm/s as compared to +3.00 cm/s near the anterior wall. At the aortic bifurcation, the locations of maximal and minimal velocities in this slice were concentrated near the lateral posterior walls. This study quantifies the magnitude of low and oscillatory velocity that may exist in the abdominal aorta and suggests that there is a strong relationship between the velocities in the retrograde direction under resting conditions and the distribution of atherosclerotic plaque.

Entities:  

Mesh:

Year:  1994        PMID: 7799637     DOI: 10.1115/1.2895740

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  21 in total

1.  Nitric oxide is significantly reduced in ex vivo porcine arteries during reverse flow because of increased superoxide production.

Authors:  X Lu; G S Kassab
Journal:  J Physiol       Date:  2004-10-07       Impact factor: 5.182

2.  A Distributed Lumped Parameter Model of Blood Flow.

Authors:  Mehran Mirramezani; Shawn C Shadden
Journal:  Ann Biomed Eng       Date:  2020-07-01       Impact factor: 3.934

3.  Measuring human placental blood flow with multidelay 3D GRASE pseudocontinuous arterial spin labeling at 3T.

Authors:  Xingfeng Shao; Dapeng Liu; Thomas Martin; Teresa Chanlaw; Sherin U Devaskar; Carla Janzen; Aisling M Murphy; Daniel Margolis; Kyunghyun Sung; Danny J J Wang
Journal:  J Magn Reson Imaging       Date:  2017-11-14       Impact factor: 4.813

4.  Quantification of hemodynamics in abdominal aortic aneurysms during rest and exercise using magnetic resonance imaging and computational fluid dynamics.

Authors:  Andrea S Les; Shawn C Shadden; C Alberto Figueroa; Jinha M Park; Maureen M Tedesco; Robert J Herfkens; Ronald L Dalman; Charles A Taylor
Journal:  Ann Biomed Eng       Date:  2010-02-09       Impact factor: 3.934

5.  Impact of flow pulsatility on arterial drug distribution in stent-based therapy.

Authors:  Caroline C O'Brien; Vijaya B Kolachalama; Tracie J Barber; Anne Simmons; Elazer R Edelman
Journal:  J Control Release       Date:  2013-03-27       Impact factor: 9.776

6.  Quantification of particle residence time in abdominal aortic aneurysms using magnetic resonance imaging and computational fluid dynamics.

Authors:  Ga-Young Suh; Andrea S Les; Adam S Tenforde; Shawn C Shadden; Ryan L Spilker; Janice J Yeung; Christopher P Cheng; Robert J Herfkens; Ronald L Dalman; Charles A Taylor
Journal:  Ann Biomed Eng       Date:  2010-11-20       Impact factor: 3.934

7.  Hemodynamic changes quantified in abdominal aortic aneurysms with increasing exercise intensity using mr exercise imaging and image-based computational fluid dynamics.

Authors:  Ga-Young Suh; Andrea S Les; Adam S Tenforde; Shawn C Shadden; Ryan L Spilker; Janice J Yeung; Christopher P Cheng; Robert J Herfkens; Ronald L Dalman; Charles A Taylor
Journal:  Ann Biomed Eng       Date:  2011-04-21       Impact factor: 3.934

8.  Flow patterns in dog aortic arch under a steady flow condition simulating mid-systole.

Authors:  S Endo; Y Sohara; T Karino
Journal:  Heart Vessels       Date:  1996       Impact factor: 2.037

9.  Effect of exercise on patient specific abdominal aortic aneurysm flow topology and mixing.

Authors:  Amirhossein Arzani; Andrea S Les; Ronald L Dalman; Shawn C Shadden
Journal:  Int J Numer Method Biomed Eng       Date:  2013-10-28       Impact factor: 2.747

10.  Influence of the renal artery ostium flow diverter on hemodynamics and atherogenesis.

Authors:  Scott Albert; Robert S Balaban; Edward B Neufeld; Jenn Stroud Rossmann
Journal:  J Biomech       Date:  2014-03-20       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.