Literature DB >> 11522729

Subcutaneous continuous glucose monitoring: feasibility of a new microdialysis-based glucose sensor system.

K Jungheim1, K J Wientjes, L Heinemann, V Lodwig, T Koschinsky, A J Schoonen.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11522729     DOI: 10.2337/diacare.24.9.1696

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


× No keyword cloud information.
  10 in total

Review 1.  Science, medicine, and the future: Microdialysis.

Authors:  Markus Müller
Journal:  BMJ       Date:  2002-03-09

2.  Accuracy of a new real-time continuous glucose monitoring algorithm.

Authors:  D Barry Keenan; Raymond Cartaya; John J Mastrototaro
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

Review 3.  Delays in minimally invasive continuous glucose monitoring devices: a review of current technology.

Authors:  D Barry Keenan; John J Mastrototaro; Gayane Voskanyan; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

4.  Professional continuous glucose monitoring in subjects with type 1 diabetes: retrospective hypoglycemia detection.

Authors:  Morten Hasselstrøm Jensen; Toke Folke Christensen; Lise Tarnow; Zeinab Mahmoudi; Mette Dencker Johansen; Ole Kristian Hejlesen
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

5.  A MEMS differential viscometric sensor for affinity glucose detection in continuous glucose monitoring.

Authors:  Xian Huang; Siqi Li; Erin Davis; Charles Leduc; Yann Ravussin; Haogang Cai; Bing Song; Dachao Li; Domenico Accili; Rudolph Leibel; Qian Wang; Qiao Lin
Journal:  J Micromech Microeng       Date:  2013-05       Impact factor: 1.881

6.  Continuous subcutaneous glucose monitoring shows a close correlation between mean glucose and time spent in hyperglycemia and hemoglobin A1c.

Authors:  Jannik Kruse Nielsen; Claus Højbjerg Gravholt; Christian Born Djurhuus; Derek Brandt; Joern Becker; Lutz Heinemann; Jens Sandahl Christiansen
Journal:  J Diabetes Sci Technol       Date:  2007-11

7.  Time lag of glucose from intravascular to interstitial compartment in humans.

Authors:  Ananda Basu; Simmi Dube; Michael Slama; Isabel Errazuriz; Jose Carlos Amezcua; Yogish C Kudva; Thomas Peyser; Rickey E Carter; Claudio Cobelli; Rita Basu
Journal:  Diabetes       Date:  2013-09-05       Impact factor: 9.461

Review 8.  Italian contributions to the development of continuous glucose monitoring sensors for diabetes management.

Authors:  Giovanni Sparacino; Mattia Zanon; Andrea Facchinetti; Chiara Zecchin; Alberto Maran; Claudio Cobelli
Journal:  Sensors (Basel)       Date:  2012-10-12       Impact factor: 3.576

9.  Hyperglycaemic index as a tool to assess glucose control: a retrospective study.

Authors:  Mathijs Vogelzang; Iwan C C van der Horst; Maarten W N Nijsten
Journal:  Crit Care       Date:  2004-03-15       Impact factor: 9.097

10.  Glucose sensing in the peritoneal space offers faster kinetics than sensing in the subcutaneous space.

Authors:  Daniel R Burnett; Lauren M Huyett; Howard C Zisser; Francis J Doyle; Brett D Mensh
Journal:  Diabetes       Date:  2014-03-12       Impact factor: 9.461

  10 in total