Literature DB >> 11487154

An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants.

J A Jenkins1, W A Walker, W G Schindler, C M Flores.   

Abstract

The purpose of this study was to evaluate the accuracy of the Root ZX in vitro in the presence of a variety of endodontic irrigants. The in vitro model, described by Donnelly, consisted of refrigerated gelatin made with 0.9% sodium chloride instead of water. The following irrigants were tested: 2% lidocaine with 1:100,000 epinephrine, 5.25% sodium hypochlorite, RC Prep, liquid EDTA, 3% hydrogen peroxide, and Peridex. A total of 30 extracted, single-rooted teeth were used. The experimental measurements in the presence of the various irrigants were compared with the actual canal lengths. The present data indicate that the Root ZX electronic apex locator reliably measured canal lengths to within 0.31 mm and that there was virtually no difference in the length determination as a function of the seven irrigants used. These results strongly support the concept that the Root ZX is a useful, versatile, and accurate device for the determination of canal lengths over a wide range of irrigants commonly used in the practice of endodontics.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11487154     DOI: 10.1097/00004770-200103000-00018

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  20 in total

1.  Precision of multi-frequency electronic apex locators.

Authors:  Roy George
Journal:  Evid Based Dent       Date:  2016-09

2.  In vitro comparison between apex locators, direct and radiographic techniques for determining the root canal length in primary teeth.

Authors:  L Z Adriano; J C Barasuol; M Cardoso; M Bolan
Journal:  Eur Arch Paediatr Dent       Date:  2019-01-02

3.  Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability.

Authors:  Franck Diemer; Emma Plews; Marie Georgelin-Gurgel; Lora Mishra; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2022-01-23       Impact factor: 3.623

4.  Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  Saru Jain; Ravi Kapur
Journal:  Contemp Clin Dent       Date:  2012-09

5.  Accuracy of Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigant.

Authors:  Hyeong-Soon Shin; Won-Kyung Yang; Mi-Ri Kim; Hyun-Jung Ko; Kyung-Mo Cho; Se-Hee Park; Jin-Woo Kim
Journal:  Restor Dent Endod       Date:  2012-08-29

6.  In vivo assessment of the impedance ratio method used in electronic foramen locators.

Authors:  Marcos V H Rambo; Humberto R Gamba; Gustavo B Borba; Joaquim M Maia; Carlos A S Ramos
Journal:  Biomed Eng Online       Date:  2010-09-06       Impact factor: 2.819

7.  Comparison of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  J Paras Mull; Vinutha Manjunath; Mk Manjunath
Journal:  J Conserv Dent       Date:  2012-04

8.  Comparison Between the Accuracy of NovApex Apex Locator and Radiographs in Determining Radiographic Apex.

Authors:  Shahriar Shahi; Saeed Rahimi; Amin Salem Milani; Mohammad Asghari Jafarabadi; Gholam Reza Djoorabbaf Naghsh
Journal:  Iran Endod J       Date:  2011-05-15

9.  A comparative evaluation of electronic and radiographic determination of root canal length in primary teeth: An in vitro study.

Authors:  Iyer Satishkumar Krishnan; Sheela Sreedharan
Journal:  Contemp Clin Dent       Date:  2012-10

10.  Comparison between two methods of working length determination and its effect on radiographic extent of root canal filling: a clinical study [ISRCTN71486641].

Authors:  L Smadi
Journal:  BMC Oral Health       Date:  2006-02-11       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.