Literature DB >> 11480601

Flat vs. concave tibial joint surface in total knee arthroplasty: randomized evaluation of 39 cases using radiostereometry.

J Uvehammer1, L Regnér, J Kärrholm.   

Abstract

40 patients with non-inflammatory arthrosis and minor preoperative deformity (< or =5 degrees ) were operated on with an AMK type (DePuy, Johnson & Johnson) total knee arthroplasty (TKA). The posterior cruciate ligament was retained. The patients were divided into those with a flat (terminology of the manufacturer: standard) or a concave (terminology of the manufacturer: constrained) polyethylene insert (20 in each group). Radiostereometric (RSA) examinations were done postoperatively and after 3,12 and 24 months. The median absolute rotations of the tibial inserts varied between 0.12 and 0.24 (range 0.00-1.54) degrees, with no differences between the 2 groups. The median maximum total-point motions (flat/concave = 0.41/0.42 mm), the maximum subsidence or lift-off did not differ. The Hospital for Special Surgery knee score and the patients' opinion about the operation, based on their preoperative expectations, showed little, if any, differences. At 2 years, 10 of 20 patients with flat and 13 of 19 with concave inserts regarded their knee function as normal or almost so.

Entities:  

Mesh:

Year:  2001        PMID: 11480601     DOI: 10.1080/00016470152846583

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  5 in total

1.  Equivalent outcomes of ultra-congruent and standard cruciate-retaining inserts in total knee arthroplasty.

Authors:  Karthik Vishwanathan; Srinivas B S Kambhampati; Raju Vaishya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-01-11       Impact factor: 4.114

2.  Posterior cruciate-retaining total knee arthroplasty for valgus osteoarthritis.

Authors:  James P McAuley; Matthew B Collier; W G Hamilton; Ehsan Tabaraee; G A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-08-19       Impact factor: 4.176

Review 3.  Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Authors:  Bart G Pijls; Edward R Valstar; Klaas-Auke Nouta; Josepha Wm Plevier; Marta Fiocco; Saskia Middeldorp; Rob Ghh Nelissen
Journal:  Acta Orthop       Date:  2012-11-09       Impact factor: 3.717

Review 4.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

5.  Lateral shift of the femoral condyle after total knee arthroplasty: simulation using 2D-templates of the medial pivot design on knee radiographs of young Japanese patients.

Authors:  Arata Nakajima; Masato Sonobe; Yorikazu Akatsu; Manabu Yamada; Keiichiro Yamamoto; Junya Saito; Masaki Norimoto; Keita Koyama; Shinji Taniguchi; Hiroshi Takahashi; Yasuchika Aoki; Toru Suguro; Koichi Nakagawa
Journal:  J Orthop Surg Res       Date:  2022-10-12       Impact factor: 2.677

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.