Literature DB >> 11477643

Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: experimental and theoretical dependence on sample properties.

M Alecci1, C M Collins, M B Smith, P Jezzard.   

Abstract

The RF B(1) distribution was studied, theoretically and experimentally, in phantoms and in the head of volunteers using a 3 T MRI system equipped with a birdcage coil. Agreement between numerical simulation and experiment demonstrates that B(1) distortion at high field can be explained with 3D full-Maxwell calculations. It was found that the B(1) distribution in the transverse plane is strongly dependent on the dielectric properties of the sample. We show that this is a consequence of RF penetration effects combined with RF standing wave effects. In contrast, along the birdcage coil z-axis the B(1) distribution is determined mainly by the coil geometry. In the transverse plane, the region of B(1) uniformity (within 10% of the maximum) was 15 cm with oil, 6 cm with distilled water, 11 cm with saline, and 10 cm in the head. Along z the B(1) uniformity was 9 cm with phantoms and 7 cm in the head.

Entities:  

Mesh:

Year:  2001        PMID: 11477643     DOI: 10.1002/mrm.1201

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

Review 1.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

2.  Assessing the Electromagnetic Fields Generated By a Radiofrequency MRI Body Coil at 64 MHz: Defeaturing Versus Accuracy.

Authors:  Elena Lucano; Micaela Liberti; Gonzalo G Mendoza; Tom Lloyd; Maria Ida Iacono; Francesca Apollonio; Steve Wedan; Wolfgang Kainz; Leonardo M Angelone
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-17       Impact factor: 4.538

Review 3.  Principles and methods for automatic and semi-automatic tissue segmentation in MRI data.

Authors:  Lei Wang; Teodora Chitiboi; Hans Meine; Matthias Günther; Horst K Hahn
Journal:  MAGMA       Date:  2016-01-11       Impact factor: 2.310

4.  Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI.

Authors:  Leonardo M Angelone; Jyrki Ahveninen; John W Belliveau; Giorgio Bonmassar
Journal:  IEEE Trans Med Imaging       Date:  2010-03-22       Impact factor: 10.048

5.  A simple method for mapping the B1 field distribution of linear RF coils.

Authors:  Jan Weis; Peter Andris; Ivan Frollo; Håkan Ahlström
Journal:  MAGMA       Date:  2005-12-13       Impact factor: 2.310

6.  Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity.

Authors:  Suwit Saekho; Chun-yu Yip; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

7.  SAR and temperature: simulations and comparison to regulatory limits for MRI.

Authors:  Zhangwei Wang; James C Lin; Weihua Mao; Wanzhan Liu; Michael B Smith; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

8.  Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.

Authors:  Ralf Mekle; Wietske van der Zwaag; Andreas Joosten; Rolf Gruetter
Journal:  MAGMA       Date:  2008-01-10       Impact factor: 2.310

9.  Calculations of B1 Distribution, Specific Energy Absorption Rate, and Intrinsic Signal-to-Noise Ratio for a Body-Size Birdcage Coil Loaded with Different Human Subjects at 64 and 128 MHz.

Authors:  W Liu; C M Collins; M B Smith
Journal:  Appl Magn Reson       Date:  2005-03       Impact factor: 0.831

10.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02
View more