Literature DB >> 11951977

Frequency shifts due to the interference of resolved peaks in magnitude-mode Fourier-transform ion cyclotron resonance mass spectra.

Aleksey V Tolmachev1, Christophe D Masselon, Gordon A Anderson, Harold R Udseth, Richard D Smith.   

Abstract

We have obtained relationships for frequency shifts resulting from the interference of spectral components for the magnitude mode Fourier transform. The approximation of a weak perturbation of well resolved peaks has been used. Both the low- and high-pressure limits for Fourier-transform ion cyclotron resonance (FTICR) operation have been considered. We have found that the shifts can be either negative or positive, depending on the initial phase and/or the choice of the time-domain interval. The magnitude of shifts generally does not exceed the peak width. In the approximation of small perturbations the shifts produced by multiple peaks are additive. We have compared theoretical results with experimental shifts for isotopic clusters of multiply charged insulin. Up to 1 ppm frequency variations were experimentally observed for the insulin 5+ charge state, consistent with theoretical estimates. The peak interference is of particular significance in the case of bio-molecular mass spectra having a large number of peaks and covering a considerable dynamic range (i.e., relative abundance). We conclude that the common mass measurement procedure based on the location of the magnitude mode maxima of well resolved peaks can result in systematic mass measurement errors. The relationships obtained provide corrections for the frequency shifts and thus improve the mass measurement accuracy.

Entities:  

Mesh:

Year:  2002        PMID: 11951977     DOI: 10.1016/S1044-0305(02)00349-5

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  23 in total

1.  Techview: biochemistry. Biomolecule mass spectrometry.

Authors:  F W McLafferty; E K Fridriksson; D M Horn; M A Lewis; R A Zubarev
Journal:  Science       Date:  1999-05-21       Impact factor: 47.728

2.  Initial implementation of an electrodynamic ion funnel with Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  M E Belov; M V Gorshkov; H R Udseth; G A Anderson; A V Tolmachev; D C Prior; R Harkewicz; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2000-01       Impact factor: 3.109

3.  Role of accurate mass measurement (+/- 10 ppm) in protein identification strategies employing MS or MS/MS and database searching.

Authors:  K R Clauser; P Baker; A L Burlingame
Journal:  Anal Chem       Date:  1999-07-15       Impact factor: 6.986

4.  Utility of accurate mass tags for proteome-wide protein identification.

Authors:  T P Conrads; G A Anderson; T D Veenstra; L Pasa-Tolić; R D Smith
Journal:  Anal Chem       Date:  2000-07-15       Impact factor: 6.986

5.  High-throughput peptide identification from protein digests using data-dependent multiplexed tandem FTICR mass spectrometry coupled with capillary liquid chromatography.

Authors:  L Li; C D Masselon; G A Anderson; L Pasa-Tolić; S W Lee; Y Shen; R Zhao; M S Lipton; T P Conrads; N Tolić; R D Smith
Journal:  Anal Chem       Date:  2001-07-15       Impact factor: 6.986

6.  High-throughput proteomics using high-efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry.

Authors:  Y Shen; N Tolić; R Zhao; L Pasa-Tolić; L Li; S J Berger; R Harkewicz; G A Anderson; M E Belov; R D Smith
Journal:  Anal Chem       Date:  2001-07-01       Impact factor: 6.986

Review 7.  Mining genomes with MS.

Authors:  J R Yates; A L McCormack; J Eng
Journal:  Anal Chem       Date:  1996-09-01       Impact factor: 6.986

8.  Cyclotron motion of two Coulombically interacting ion clouds with implications to Fourier-transform ion cyclotron resonance mass spectrometry.

Authors: 
Journal:  Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics       Date:  1995-10

9.  Identification of the components of simple protein mixtures by high-accuracy peptide mass mapping and database searching.

Authors:  O N Jensen; A V Podtelejnikov; M Mann
Journal:  Anal Chem       Date:  1997-12-01       Impact factor: 6.986

10.  Protein identification by mass profile fingerprinting.

Authors:  P James; M Quadroni; E Carafoli; G Gonnet
Journal:  Biochem Biophys Res Commun       Date:  1993-08-31       Impact factor: 3.575

View more
  3 in total

1.  Data processing for 3D mass spectrometry imaging.

Authors:  Xingchuang Xiong; Wei Xu; Livia S Eberlin; Justin M Wiseman; Xiang Fang; You Jiang; Zejian Huang; Yukui Zhang; R Graham Cooks; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2012-03-03       Impact factor: 3.109

2.  Phase correction of Fourier transform ion cyclotron resonance mass spectra using MatLab.

Authors:  Yulin Qi; Christopher J Thompson; Steve L Van Orden; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-28       Impact factor: 3.109

3.  Least-squares fitting of time-domain signals for Fourier transform mass spectrometry.

Authors:  Tagir Aushev; Anton N Kozhinov; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2014-05-01       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.