Characterization of the metabolic demands of simulated shipboard Royal Navy fire-fighting tasks.

J L Bilzon1, E G Scarpello, C V Smith, N A Ravenhill, M P Rayson.   

Abstract

The purpose of this study was to quantify the metabolic demand of simulated shipboard fire-fighting procedures currently practised by men and women in the Royal Navy (RN) and to identify a minimum level of cardiovascular fitness commensurate with satisfactory performance. Thirty-four males (M) and 15 females (F) volunteered as subjects for this study (n=49). Maximal oxygen uptake (VO2max) and heart rate (fcmax) of each subject was assessed during a standardized treadmill test. During the main trials, volunteers were randomly assigned to complete several 4-min simulated shipboard fire-fighting tasks (boundary cooling (BC), drum carry (DC), extinguisher carry (EC), hose run (HR), ladder climb (LC)), at a work rate that was endorsed as a minimum acceptable standard. Heart rate (fc) and oxygen uptake (VO2) were recorded at 10-s intervals during rest, exercise and recovery. Participants completed all tasks within an allocated time with the exception of the DC task, where 11 subjects (all females) failed to maintain the endorsed work rate. The DC task elicited the highest (p<0.01) group mean peak metabolic demand (PMD) in males (43 ml min(-1) kg(-1)) and females (42 ml min(-1) kg (-1)) who were able to maintain the endorsed work rate. The BC task elicited the lowest PMD (23 ml min(-1) kg(-1)), whilst the remaining three tasks elicited a remarkably similar PMD of 38-39 ml min(-1) kg(-1). The human endurance limit while wearing a self-contained breathing apparatus (SCBA) dictates that RN personnel are only able to fire-fight for 20-30 min, while wearing a full fire-fighting ensemble (FFE) and performing a combination of the BC, HR and LC tasks, which have a group mean metabolic demand of 32.8 ml min(-1) kg(-1). Given that in healthy subjects fire-fighting can be sustained at a maximum work intensity of 80% VO2max when wearing SCBA for this duration, it is recommended that all RN personnel achieve a VO2max of 41 ml min(-1) kg(-1) as an absolute minimum standard. Subjects with a higher VO2max than the above quoted minimum are able to complete the combination of tasks listed with greater metabolic efficiency and less fatigue.

Entities:  

Mesh:

Year:  2001        PMID: 11450875     DOI: 10.1080/00140130118253

Source DB:  PubMed          Journal:  Ergonomics        ISSN: 0014-0139            Impact factor:   2.778


  17 in total

1.  Development of a perceptual hyperthermia index to evaluate heat strain during treadmill exercise.

Authors:  Michael Gallagher; Robert J Robertson; Fredric L Goss; Elizabeth F Nagle-Stilley; Mark A Schafer; Joe Suyama; David Hostler
Journal:  Eur J Appl Physiol       Date:  2011-09-23       Impact factor: 3.078

2.  The impact of different cooling modalities on the physiological responses in firefighters during strenuous work performed in high environmental temperatures.

Authors:  David Barr; Thomas Reilly; Warren Gregson
Journal:  Eur J Appl Physiol       Date:  2010-11-16       Impact factor: 3.078

3.  The impact of firefighter personal protective equipment and treadmill protocol on maximal oxygen uptake.

Authors:  Joo-Young Lee; Ilham Bakri; Jung-Hyun Kim; Su-Young Son; Yutaka Tochihara
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

4.  Respiratory gas exchange and physiological demands during a fire fighter evaluation circuit in men and women.

Authors:  D G Harvey; J L Kraemer; M T Sharratt; R L Hughson
Journal:  Eur J Appl Physiol       Date:  2008-01-19       Impact factor: 3.078

5.  Comparison of rehydration regimens for rehabilitation of firefighters performing heavy exercise in thermal protective clothing: a report from the fireground rehab evaluation (FIRE) trial.

Authors:  David Hostler; James C Bednez; Sarah Kerin; Steven E Reis; Pui Wah Kong; Julia Morley; Michael Gallagher; Joe Suyama
Journal:  Prehosp Emerg Care       Date:  2010 Apr-Jun       Impact factor: 3.077

6.  The effects of protective clothing on energy consumption during different activities.

Authors:  Lucy E Dorman; George Havenith
Journal:  Eur J Appl Physiol       Date:  2008-11-15       Impact factor: 3.078

Review 7.  Physiological employment standards I. Occupational fitness standards: objectively subjective?

Authors:  M J Tipton; G S Milligan; T J Reilly
Journal:  Eur J Appl Physiol       Date:  2012-12-23       Impact factor: 3.078

8.  Qualitative study on voyaging and health: perspectives and insights from the medical officers during the Worldwide Voyage.

Authors:  Marjorie K Leimomi Mala Mau; Christina Mie Minami; Sarah A Stotz; Cheryl L Albright; Shawn Malia Kana'iaupuni; Heidi Kai Guth
Journal:  BMJ Open       Date:  2021-07-07       Impact factor: 2.692

9.  The prevalence of cardiovascular disease risk factors and obesity in firefighters.

Authors:  Denise L Smith; Patricia C Fehling; Adam Frisch; Jeannie M Haller; Molly Winke; Michael W Dailey
Journal:  J Obes       Date:  2012-07-22

10.  Field tests for evaluating the aerobic work capacity of firefighters.

Authors:  Ann-Sofie Lindberg; Juha Oksa; Désirée Gavhed; Christer Malm
Journal:  PLoS One       Date:  2013-07-02       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.