Literature DB >> 18204853

Respiratory gas exchange and physiological demands during a fire fighter evaluation circuit in men and women.

D G Harvey1, J L Kraemer, M T Sharratt, R L Hughson.   

Abstract

We examined the oxygen uptake (VO2) and carbon dioxide output (VCO2) during completion of a circuit developed for testing fire fighters and related performance time to laboratory measures of fitness. Twenty-two healthy university students (ten women) were trained in the tasks then performed the circuit as quickly as possible. Breath-by-breath gas exchange and heart rate were continuously measured with a portable system. Median circuit time was 6:13 (min:s, 25-75% = 5:46-6:42) for men and 7:25 (25-75% = 6:49-10:21) for 8 women finishers (P = 0.023), and VO2 averaged 68 and 64% VO2max for the men and women during the circuit. Both men and women had high respiratory exchange ratios (>1.0) suggesting marked anaerobic energy contribution. Physiological variables associated with circuit time were assessed by backward stepwise regression yielding a significant model that included only peak work rate during arm cranking exercise as a function of circuit completion time across men and women combined (P < 0.001). For men, but especially for women, the time required for the simulated victim drag (68.2 kg mannequin) was positively correlated with total time to complete the other circuit elements (r = 0.51, r = 0.96 respectively). The simple correlation between circuit time and VO2max (mL/kg/min) revealed poor relationships for men (r = -0.37, P > 0.05) and women (r = 0.20, P > 0.05). These data demonstrated that upper body fitness as reflected by peak work rate during arm cranking correlated with total circuit time for the men and women in our population sample.

Entities:  

Mesh:

Year:  2008        PMID: 18204853     DOI: 10.1007/s00421-008-0673-2

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  21 in total

1.  Relationship between fire fighting suppression tasks and physical fitness.

Authors:  H N Williford; W J Duey; M S Olson; R Howard; N Wang
Journal:  Ergonomics       Date:  1999-09       Impact factor: 2.778

2.  Development and validation of a fitness screening protocol for firefighter applicants.

Authors:  N Gledhill; V K Jamnik
Journal:  Can J Sport Sci       Date:  1992-09

3.  Classification of metabolic and respiratory demands in fire fighting activity with extreme workloads.

Authors:  Ingvar Holmér; Désirée Gavhed
Journal:  Appl Ergon       Date:  2006-03-03       Impact factor: 3.661

4.  Performance differences between males and females on simulated firefighting tasks.

Authors:  J E Misner; S A Plowman; R A Boileau
Journal:  J Occup Med       Date:  1987-10

5.  Maximal physical work performance with European standard based fire-protective clothing system and equipment in relation to individual characteristics.

Authors:  V Louhevaara; R Ilmarinen; B Griefahn; C Künemund; H Mäkinen
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

6.  Cardiorespiratory strain in jobs that require respiratory protection.

Authors:  V Louhevaara; T Tuomi; J Smolander; O Korhonen; A Tossavainen; J Jaakkola
Journal:  Int Arch Occup Environ Health       Date:  1985       Impact factor: 3.015

7.  Acceleration of VO2 kinetics in heavy submaximal exercise by hyperoxia and prior high-intensity exercise.

Authors:  M Macdonald; P K Pedersen; R L Hughson
Journal:  J Appl Physiol (1985)       Date:  1997-10

8.  Physiological responses of firefighters and performance predictors during a simulated rescue of hospital patients.

Authors:  Erna D von Heimburg; Anna Kari R Rasmussen; Jon Ingulf Medbø
Journal:  Ergonomics       Date:  2006-02-10       Impact factor: 2.778

9.  Oxygen uptake kinetics during two bouts of heavy cycling separated by fatiguing sprint exercise in humans.

Authors:  N Tordi; S Perrey; A Harvey; R L Hughson
Journal:  J Appl Physiol (1985)       Date:  2002-10-11

10.  Blood acid-base and lactate relationships studied by ramp work tests.

Authors:  R L Hughson; H J Green
Journal:  Med Sci Sports Exerc       Date:  1982       Impact factor: 5.411

View more
  5 in total

1.  The impact of firefighter personal protective equipment and treadmill protocol on maximal oxygen uptake.

Authors:  Joo-Young Lee; Ilham Bakri; Jung-Hyun Kim; Su-Young Son; Yutaka Tochihara
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

2.  Multivariate statistical assessment of predictors of firefighters' muscular and aerobic work capacity.

Authors:  Ann-Sofie Lindberg; Juha Oksa; Henrik Antti; Christer Malm
Journal:  PLoS One       Date:  2015-03-16       Impact factor: 3.240

3.  Relationships between strength and endurance parameters and air depletion rates in professional firefighters.

Authors:  Stephanie Windisch; Wolfgang Seiberl; Ansgar Schwirtz; Daniel Hahn
Journal:  Sci Rep       Date:  2017-03-17       Impact factor: 4.379

4.  Field tests for evaluating the aerobic work capacity of firefighters.

Authors:  Ann-Sofie Lindberg; Juha Oksa; Désirée Gavhed; Christer Malm
Journal:  PLoS One       Date:  2013-07-02       Impact factor: 3.240

5.  Oxygen Consumption (V'O2) and physical Strainas measured by the occupational activity of cleaning personnel.

Authors:  M J Fröhlich; R F Kroidl; T Welte
Journal:  J Occup Med Toxicol       Date:  2018-01-19       Impact factor: 2.646

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.