Literature DB >> 20671815

Evaluation of J-initiation fracture toughness of ultra high molecular weight polyethylene used in total joint replacements.

R Varadarajan1, C M Rimnac.   

Abstract

Fracture of ultra high molecular weight polyethylene (UHMWPE) total joint replacement components is a clinical concern. Thus, it is important to characterize the fracture resistance of UHMWPE. To determine J-initiation fracture toughness (J(Q)) for metals and metallic alloys, ASTM E1820 recommends a procedure based on an empirical crack blunting line. This approach has been found to overestimate the initiation toughness of tough polymers like UHMWPE. Therefore, in this study, a novel experimental approach based on crack tip opening displacement (CTOD) was utilized to evaluate J(Q) of UHMWPE materials. J-initiation fracture toughness was experimentally measured in ambient air and a physiologically-relevant 37°C PBS environment for three different formulations of UHMWPE and compared to the blunting line approach. The CTOD method was found to provide J(Q) values comparable to the blunting line approach for the UHMWPE materials and environments examined in this study. The CTOD method used in this study is based on experimental observation and, thus, does not rely on an empirical relationship or fracture surface measurements. Therefore, determining J(Q) using the experimentally based CTOD method proposed in this study may be a more reliable approach for UHMWPE and other tough polymers than the blunting line approach.

Entities:  

Year:  2008        PMID: 20671815      PMCID: PMC2911369          DOI: 10.1016/j.polymertesting.2008.03.007

Source DB:  PubMed          Journal:  Polym Test        ISSN: 0142-9418            Impact factor:   4.282


  6 in total

1.  J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE.

Authors:  A Gomoll; T Wanich; A Bellare
Journal:  J Orthop Res       Date:  2002-11       Impact factor: 3.494

2.  Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high-molecular-weight polyethylene.

Authors:  R S Pascaud; W T Evans; P J McCullagh; D P FitzPatrick
Journal:  Biomaterials       Date:  1997-05       Impact factor: 12.479

3.  Constituents and pH changes in protein rich hyaluronan solution affect the biotribological properties of artificial articular joints.

Authors:  T Kitano; G A Ateshian; V C Mow; Y Kadoya; Y Yamano
Journal:  J Biomech       Date:  2001-08       Impact factor: 2.712

4.  Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE.

Authors:  Jantzen C Cole; Jack E Lemons; Alan W Eberhardt
Journal:  J Biomed Mater Res       Date:  2002

5.  Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements.

Authors:  S M Kurtz; M L Villarraga; M P Herr; J S Bergström; C M Rimnac; A A Edidin
Journal:  Biomaterials       Date:  2002-09       Impact factor: 12.479

6.  Static fracture resistance of ultra high molecular weight polyethylene using the single specimen normalization method.

Authors:  R Varadarajan; E K Dapp; C M Rimnac
Journal:  Polym Test       Date:  2008-04       Impact factor: 4.282

  6 in total
  4 in total

1.  Crack propagation resistance is similar under static and cyclic loading in crosslinked UHMWPE: a pilot study.

Authors:  Jevan Furmanski; Clare M Rimnac
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

2.  Crack initiation from a clinically relevant notch in a highly-crosslinked UHMWPE subjected to static and cyclic loading.

Authors:  Abhi Sirimamilla; Clare M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2018-12-28

3.  Application of viscoelastic fracture model and non-uniform crack initiation at clinically relevant notches in crosslinked UHMWPE.

Authors:  P Abhiram Sirimamilla; Jevan Furmanski; Clare M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2012-08-01

4.  Viscoplastic crack initiation and propagation in crosslinked UHMWPE from clinically relevant notches up to 0.5mm radius.

Authors:  P Abhiram Sirimamilla; Clare M Rimnac; Jevan Furmanski
Journal:  J Mech Behav Biomed Mater       Date:  2017-09-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.