Literature DB >> 11442177

Influence of scan radius correction for ocular magnification and relationship between scan radius with retinal nerve fiber layer thickness measured by optical coherence tomography.

S Bayraktar1, Z Bayraktar, O F Yilmaz.   

Abstract

PURPOSE: To investigate how optical coherence tomography (OCT) modifies the preset scan parameters to correct the errors resulting from ocular magnification, the influence of examiner's final correction of those already modified parameters on retinal nerve fiber layer (RNFL) thickness measurements, the induced change on RNFL thickness measurements and RNFL estimated integrals (RNFL(estimated integrals)) by adjusting the actual scan radius during RNFL examinations performed by OCT.
METHODS: Thirty-five healthy patients underwent an RNFL examination by OCT four times using different scan radii. The first scan was performed with the preset circular scan diameter of 3.46 mm; the actual scan diameter was different, however, because it was modified by the OCT instrument. The second, third, and fourth scans were generated after readjusting the already modified scan diameter by the examiner to 3.46, 3.20, and 3.60 mm. The relationship of axial length and refractive error with the actual scan radius (with ocular magnification calculated by OCT), with the influence of the examiner's final correction on RNFL thickness measurements, with the relationship between scan radius with RNFL thickness measurements, and with RNFL(estimated integrals) were investigated.
RESULTS: The actual scan diameter was found to be primarily determined by axial length (R = 0.97, P < 0.0001), but the influence of refractive error was small (R = -0.26, P = 0.067). Final correction of the actual scan radius by the examiner had a significant influence on RNFL thickness measurements (P = 0.025). RNFL thickness measurements obtained without correction of the actual scan radius for magnification were found to be inversely correlated with axial length (R = -0.54, P = 0.001), whereas no similar relationship was found when RNFL thickness measurements were obtained with correction (R = 0.21, P = 0.11). A reciprocal relationship between 1/scan radius with RNFL thickness measurements (they tended to be thinner as scan radii were increased) was found (R = 0.41, P = 0.169), but RNFL(estimated integrals) areas were found to be independent of the scan radius (P = 0.521).
CONCLUSION: To increase the accuracy of RNFL thickness measurements, it will be appropriate for the examiner to manually correct the actual scan parameters to the desired or preset ones after their automatic modification performed by the OCT instrument. Keeping the actual scan radius constant for repeated exams is also recommended because RNFL thickness measurements were found to depend on scan size. Alternatively, RNFL(estimated integrals) could be used because they were found to be independent of the scan size.

Entities:  

Mesh:

Year:  2001        PMID: 11442177     DOI: 10.1097/00061198-200106000-00004

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  22 in total

1.  Modelling the normal retinal nerve fibre layer thickness as measured by Stratus optical coherence tomography.

Authors:  Jesper Leth Hougaard; Carl Ostenfeld; Anders Heijl; Boel Bengtsson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-12       Impact factor: 3.117

2.  Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning.

Authors:  Michelle L Gabriele; Hiroshi Ishikawa; Gadi Wollstein; Richard A Bilonick; Larry Kagemann; Maciej Wojtkowski; Vivek J Srinivasan; James G Fujimoto; Jay S Duker; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-07       Impact factor: 4.799

3.  The effects of ocular magnification on Spectralis spectral domain optical coherence tomography scan length.

Authors:  Irene Ctori; Stephen Gruppetta; Byki Huntjens
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-01-10       Impact factor: 3.117

4.  Influence of anterior segment power on the scan path and RNFL thickness using SD-OCT.

Authors:  Nimesh B Patel; Brenda Garcia; Ronald S Harwerth
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-08-24       Impact factor: 4.799

5.  Effects of multiple intravitreal anti-VEGF injections on retinal nerve fiber layer and intraocular pressure: a comparative clinical study.

Authors:  Güngör Sobacı; Rıza Güngör; Gökhan Ozge
Journal:  Int J Ophthalmol       Date:  2013-04-18       Impact factor: 1.779

6.  Does optic nerve head size variation affect circumpapillary retinal nerve fiber layer thickness measurement by optical coherence tomography?

Authors:  David Huang; Vikas Chopra; Ake Tzu-Hui Lu; Ou Tan; Brian Francis; Rohit Varma
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-07-27       Impact factor: 4.799

7.  Age, ocular magnification, and circumpapillary retinal nerve fiber layer thickness.

Authors:  Mengyu Wang; Tobias Elze; Dian Li; Neda Baniasadi; Kerstin Wirkner; Toralf Kirsten; Joachim Thiery; Markus Loeffler; Christoph Engel; Franziska G Rauscher
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

8.  Agreement between retinal nerve fiber layer measures from Spectralis and Cirrus spectral domain OCT.

Authors:  Nimesh B Patel; Joe L Wheat; Aldon Rodriguez; Victoria Tran; Ronald S Harwerth
Journal:  Optom Vis Sci       Date:  2012-05       Impact factor: 1.973

9.  Age-associated changes in the retinal nerve fiber layer and optic nerve head.

Authors:  Nimesh B Patel; Mimi Lim; Avni Gajjar; Kelsey B Evans; Ronald S Harwerth
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-07-22       Impact factor: 4.799

10.  Retinal nerve fibre layer thickness analysis in X-linked retinoschisis using Fourier-domain OCT.

Authors:  M A Genead; S Pasadhika; G A Fishman
Journal:  Eye (Lond)       Date:  2009-04-17       Impact factor: 3.775

View more