Literature DB >> 11429939

Mandibular overdentures supported by two Brånemark, IMZ or ITI implants. A prospective comparative preliminary study: one-year results.

R H Batenburg1, H J Meijer, G M Raghoebar, R P Van Oort, G Boering.   

Abstract

The aim of this prospective comparative study was to evaluate the condition of the peri-implant tissues of three different implant systems supporting a mandibular overdenture. Ninety edentulous patients (Cawood class V-VI) participated in this study. After randomization, 30 patients were treated with 2 Brånemark implants, 30 patients with 2 IMZ implants and 30 patients with 2 ITI implants. The implants were inserted in the canine region of the mandible. After 3 months overdentures were fabricated supported by a round bar and clip attachment. A standardized clinical and radiographic evaluation was performed 0,6 and 12 months after insertion of the denture. The intraoral radiographs were made, using the long-cone technique with an aiming device. Two implants were lost (1 Brånemark, 1 IMZ) during the healing period. None of the patients showed any sensory change in lip or chin region. The pocket depth in the Brånemark group decreased significantly whereas the mucosa recession increased significantly in both the Brånemark as well as in the IMZ group. After 12 months, there was significantly less bone loss in the ITI group. From our study it was concluded that 2 (Brånemark, IMZ or ITI) implants placed in the interforaminal region connected with a bar supply a proper base for the support of a mandibular overdenture in the (Cawood V-VI) edentulous patient. The ITI implant appears to be the implant of choice for mandibular overdenture therapy, because only one operation is required for a comparable result.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 11429939     DOI: 10.1034/j.1600-0501.1996.090603.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

Review 1.  Titanium oral implants: surface characteristics, interface biology and clinical outcome.

Authors:  Anders Palmquist; Omar M Omar; Marco Esposito; Jukka Lausmaa; Peter Thomsen
Journal:  J R Soc Interface       Date:  2010-06-30       Impact factor: 4.118

2.  Implant retained auricular prosthesis with a modified hader bar: a case report.

Authors:  M Lovely; Pradeep C Dathan; Dinesh Gopal; Biji Thomas George; K Chandrasekharan Nair
Journal:  J Indian Prosthodont Soc       Date:  2013-03-21

3.  Mandibular fractures associated with endosteal implants.

Authors:  Bruno Ramos Chrcanovic; Antônio Luís Neto Custódio
Journal:  Oral Maxillofac Surg       Date:  2009-12

Review 4.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

5.  Mandibular implant-supported overdentures in (frail) elderly: A prospective study with 20-year follow-up.

Authors:  Mieke H Bakker; Arjan Vissink; Henny J A Meijer; Gerry M Raghoebar; Anita Visser
Journal:  Clin Implant Dent Relat Res       Date:  2019-04-16       Impact factor: 3.932

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.