Literature DB >> 11418423

Multislice helical CT of focal and diffuse lung disease: comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan.

U J Schoepf1, R D Bruening, C Hong, R Eibel, S Aydemir, A Crispin, C Becker, M F Reiser.   

Abstract

OBJECTIVE: We tested breath-held 1-mm multislice helical CT for obtaining both contiguous and high-resolution CT sections of the chest from a single set of raw data. SUBJECTS AND METHODS: Seventy patients with suspected focal and diffuse lung disease were allocated into two groups for comparison. The first group (n = 35) underwent multislice helical CT of the chest with 1-mm collimation and a pitch of 6. From the raw data, 5-mm contiguous and 1.25-mm high-resolution CT sections were reconstructed. The second group (n = 35) underwent conventional single-slice helical CT and high-resolution CT. High-resolution CT sections and 5-mm scans were rated for overall image quality, spatial resolution, subjective signal-to-noise ratio, diagnostic value, depiction of bronchi and parenchyma, and motion and streak artifacts. The 5-mm scans were also rated for contrast resolution and depiction of the heart and vessels. Radiation dose was calculated.
RESULTS: We rated 5-mm multislice helical CT superior to 5-mm single-slice helical CT, having a significantly higher total score (p = 0.0001). No significant difference (p = 0.986) was found between multislice and single-slice high-resolution CT sections. Radiation dose was 5.55 mSv for multislice helical CT and 5.50 mSv for single-slice helical CT.
CONCLUSION: Contiguous chest scans of superior quality and high-resolution CT sections of equal image quality compared with single-slice helical CT can be obtained using multislice helical CT. Therefore, a comprehensive diagnosis is feasible in patients with suspected focal and diffuse lung disease by obtaining a single scan.

Entities:  

Mesh:

Year:  2001        PMID: 11418423     DOI: 10.2214/ajr.177.1.1770179

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

1.  Computer-assisted detection of pulmonary nodules: preliminary observations using a prototype system with multidetector-row CT data sets.

Authors:  Leo P Lawler; Susan A Wood; Harpreet K Pannu; Elliot K Fishman; Harpreet S Pannu
Journal:  J Digit Imaging       Date:  2003-12-15       Impact factor: 4.056

2.  Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients.

Authors:  François Pontana; Julien Pagniez; Thomas Flohr; Jean-Baptiste Faivre; Alain Duhamel; Jacques Remy; Martine Remy-Jardin
Journal:  Eur Radiol       Date:  2010-11-05       Impact factor: 5.315

3.  Diagnosis and antimicrobial therapy of lung infiltrates in febrile neutropenic cancer patients.

Authors:  Georg Maschmeyer
Journal:  Curr Infect Dis Rep       Date:  2011-12       Impact factor: 3.725

4.  The value of multislice spiral CT features of cavitary walls in differentiating between peripheral lung cancer cavities and single pulmonary tuberculous thick-walled cavities.

Authors:  B-G Li; D-Q Ma; Z-Y Xian; J Guan; K-J Luo; Q-W Fan; L Peng; W He
Journal:  Br J Radiol       Date:  2012-02       Impact factor: 3.039

5.  Multislice CT angiography.

Authors:  U Joseph Schoepf; Christoph R Becker; Lars K Hofmann; Marco Das; Thomas Flohr; Bernd M Ohnesorge; Bernhard Baumert; Joshua Rolnick; Jean M Allen; Vassilios Raptopoulos
Journal:  Eur Radiol       Date:  2003-02-26       Impact factor: 5.315

6.  Determination of a standard deviation that could minimize radiation exposure in an automatic exposure control for pulmonary thin-section computed tomography.

Authors:  Atsushi Nambu; Eiichi Sawada; Satoshi Kato; Tsutomu Araki; Yoshihito Aikawa; Makoto Yuge; Akitoshi Saito
Journal:  Jpn J Radiol       Date:  2011-07-24       Impact factor: 2.374

Review 7.  [HRCT technique with low-dose protocols for interstitial lung diseases].

Authors:  J Ley-Zaporozhan; S Ley
Journal:  Radiologe       Date:  2014-12       Impact factor: 0.635

8.  Pulmonary multislice computed tomography findings in acute aortic dissection.

Authors:  Aslihan Semiz-Oysu; Aysegul Okur; Sinan Sahin
Journal:  J Thorac Dis       Date:  2012-10       Impact factor: 2.895

9.  The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters.

Authors:  Ji Hoon Shin; Ho Kyu Lee; Choong Gon Choi; Dae Chul Suh; Tae Hwan Lim; Weechang Kang
Journal:  Korean J Radiol       Date:  2002 Jan-Mar       Impact factor: 3.500

10.  Correlation Between Pulmonary Sclerosing Pneumocytoma Features and MSCT Imaging Manifestations in 34 Patients: Implications for Precision Medicine.

Authors:  Gen Xu; Zhaoyu Wang; Zeng Xiong; Manqiu Li; Weijun Luo; Yong Xu; Tang Min
Journal:  Front Med (Lausanne)       Date:  2021-03-18
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.