Literature DB >> 11414523

Correlation of external and internal monitoring of uterine activity in a cohort of term patients.

A M Miles1, M Monga, K S Richeson.   

Abstract

External tocodynamometry (ET) and intrauterine pressure monitoring (IUPC) are commonly used to assess uterine contractile activity. It is believed that ET does not accurately document contraction amplitude. However, no direct comparison of ET and IUPC has been published in term patients. Our objective was to determine the correlation between frequency, duration, and amplitude as measured by ET and IUPC. Twenty patients between 36 and 41 weeks' gestation were enrolled during active spontaneous labor. Uterine contractions were recorded simultaneously by ET and IUPC for 2 hours. ET and IUPC data were compared using the Spearman correlation coefficient and the Wilcoxon signed-rank test. The median body mass index (BMI) of the patient population was 31.8 kg/m2 (range 22.2 to 42.3). There was good correlation of contraction frequency measured by ET and IUPC (r = 0.75, p = 0.001), but poor correlation of both contraction amplitude (r = 0.26) and duration (r = 0.27). ET and IUPC assessment of uterine contractile activity, specifically contraction amplitude and duration, do not appear to correlate in a population of moderately obese patients. This suggests that ET should not exclusively be relied upon in this population to assess uterine contractile activity during labor.

Entities:  

Mesh:

Year:  2001        PMID: 11414523     DOI: 10.1055/s-2001-14522

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  4 in total

1.  The Impact of Maternal Body Mass Index and Gestational Age on the Detection of Uterine Contractions by Tocodynamometry: A Retrospective Study.

Authors:  A Aina-Mumuney; K Hwang; N Sunwoo; I Burd; K Blakemore
Journal:  Reprod Sci       Date:  2015-10-22       Impact factor: 3.060

2.  Vaginal electrohysterography: the design and preliminary evaluation of a novel device for uterine contraction monitoring in an ovine model (.).

Authors:  Nate Sunwoo; Karin Hwang; Karin J Blakemore; Abimbola Aina-Mumuney
Journal:  J Matern Fetal Neonatal Med       Date:  2015-11-23

3.  Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects.

Authors:  C Muszynski; T Happillon; K Azudin; J-B Tylcz; D Istrate; C Marque
Journal:  BMC Pregnancy Childbirth       Date:  2018-05-08       Impact factor: 3.007

4.  Automatic identification of motion artifacts in EHG recording for robust analysis of uterine contractions.

Authors:  Yiyao Ye-Lin; Javier Garcia-Casado; Gema Prats-Boluda; José Alberola-Rubio; Alfredo Perales
Journal:  Comput Math Methods Med       Date:  2014-01-09       Impact factor: 2.238

  4 in total