Literature DB >> 26458732

Vaginal electrohysterography: the design and preliminary evaluation of a novel device for uterine contraction monitoring in an ovine model (.).

Nate Sunwoo1, Karin Hwang1, Karin J Blakemore2, Abimbola Aina-Mumuney2.   

Abstract

OBJECTIVE: Tocodynamometry is the most common method of labor evaluation but most clinicians would agree it has limited utility before 26 weeks of gestation. The obesity epidemic has further reduced our ability to accurately detect uterine contractions using the tocodynamometer at any gestational age. We sought to design and test a novel contraction monitor that bypasses the maternal abdomen.
METHODS: An optimized version of an intravaginal electrohysterographic ring device was tested in an ovine model. The device and its methodology as well as the tocodynamometer were validated against the current gold standard uterine activity monitor, the intrauterine pressure catheter in six sheep at varying gestational ages.
RESULTS: Both the intravaginal ring device and the tocodynamometer correlated well with IUPC, r = 0.69 and 0.73, respectively (p < 0.001). The number of contractions detected by each monitor remained similar even after accounting for confounders.
CONCLUSIONS: These results suggest that uterine activity can be monitored from the vaginal interface in an ovine model and offers an alternative clinical tool for the detection of contractions in situations, in which tocodynamometry would be ineffective or intrauterine monitoring inappropriate.

Entities:  

Keywords:  Contraction monitoring; electrohysterograph; preterm labor; tocodynamometry; uterine contraction

Mesh:

Year:  2015        PMID: 26458732      PMCID: PMC4882273          DOI: 10.3109/14767058.2015.1107538

Source DB:  PubMed          Journal:  J Matern Fetal Neonatal Med        ISSN: 1476-4954


  28 in total

Review 1.  Instrumentation for the diagnosis of term and preterm labour.

Authors:  R E Garfield; K Chwalisz; L Shi; G Olson; G R Saade
Journal:  J Perinat Med       Date:  1998       Impact factor: 1.901

2.  Electrical activity of the human uterus in labor.

Authors:  S D LARKS; N S ASSALI; D G MORTON; W A SELLE
Journal:  J Appl Physiol       Date:  1957-05       Impact factor: 3.531

3.  Cutaneous and uterine electrical potentials in labor; an experiment.

Authors:  E H HON; C D DAVIS
Journal:  Obstet Gynecol       Date:  1958-07       Impact factor: 7.661

4.  The electrical activity of the human uterus in normal and abnormal labor.

Authors:  C M STEER
Journal:  Am J Obstet Gynecol       Date:  1954-09       Impact factor: 8.661

5.  Electrical activity of the human uterus in labor; the electrohysterograph.

Authors:  C M STEER; G J HERTSCH
Journal:  Am J Obstet Gynecol       Date:  1950-01       Impact factor: 8.661

6.  Longitudinally and circularly measured EMG activity in the human uterine cervix during labour.

Authors:  M Pajntar; E Roskar; D Rudel
Journal:  Acta Physiol Hung       Date:  1988

7.  Electrical and mechanical activity of the human uterus during labour.

Authors:  G Wolfs; H Rottinghuis
Journal:  Arch Gynakol       Date:  1970-04-30

8.  Electrohysterography during pregnancy: preliminary report.

Authors:  J Gondry; C Marque; J Duchene; D Cabrol
Journal:  Biomed Instrum Technol       Date:  1993 Jul-Aug

9.  Monitoring women at risk for preterm labor.

Authors:  D C Dyson; K H Danbe; J A Bamber; Y M Crites; D R Field; J A Maier; L A Newman; D A Ray; D L Walton; M A Armstrong
Journal:  N Engl J Med       Date:  1998-01-01       Impact factor: 91.245

10.  Non-invasive transabdominal uterine electromyography correlates with the strength of intrauterine pressure and is predictive of labor and delivery.

Authors:  H Maul; W L Maner; G Olson; G R Saade; R E Garfield
Journal:  J Matern Fetal Neonatal Med       Date:  2004-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.