Literature DB >> 11410180

Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation.

S J Piazza1, N Okita, P R Cavanagh.   

Abstract

Accurate location of the hip joint center is essential for computation of hip kinematics and kinetics as well as for determination of the moment arms of muscles crossing the hip. The functional method of hip joint center location involves fitting a pelvis-fixed sphere to the path traced by a thigh-fixed point while a subject performs hip motions; the center of this sphere is the hip joint center. The aim of the present study was to evaluate the potential accuracy of the functional method and the dependence of its accuracy on variations in its implementation and the amount of available hip motion. The motions of a mechanical linkage were studied to isolate the factors of interest, removing errors due to skin movement and the palpation of bony landmarks that are always present in human studies. It was found that reducing the range of hip motion from 30 degrees to 15 degrees did significantly increase hip joint center location errors, but that restricting motion to a single plane did not. The magnitudes of these errors, however, even in the least accurate cases, were smaller than those previously reported for either the functional method or other methods based on pelvis measurements of living subjects and cadaver specimens. Neither increasing the number of motion data observations nor analyzing the motion of a single thigh marker (rather than the centroid of multiple markers) was found to significantly increase error. The results of this study (1) imply that the limited range of motion that is often evident in subjects with hip pathology does not preclude accurate determination of the hip joint center when the functional method is used; and (2) provide guidelines for the use of the functional method in human subjects.

Entities:  

Mesh:

Year:  2001        PMID: 11410180     DOI: 10.1016/s0021-9290(01)00052-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  35 in total

1.  Sensitivity of hip tissues contact evaluation to the methods used for estimating the hip joint center of rotation.

Authors:  Ehsan Arbabi; Jerome Schmid; Ronan Boulic; Daniel Thalmann; Nadia Magnenat-Thalmann
Journal:  Med Biol Eng Comput       Date:  2012-02-29       Impact factor: 2.602

2.  Experimental determination of the elbow's center of rotation using the VICON™ optoelectronic motion capture system.

Authors:  Elvire Guerre; Pascale Laronde; Jérôme Cussonneau; Christian Fontaine; Guillaume Wavreille
Journal:  Surg Radiol Anat       Date:  2015-11-20       Impact factor: 1.246

3.  Kinematic and electromyography analysis of submaximal differences running on a firm surface compared with soft, dry sand.

Authors:  Hugh C Pinnington; David G Lloyd; Thor F Besier; Brian Dawson
Journal:  Eur J Appl Physiol       Date:  2005-04-07       Impact factor: 3.078

4.  The independent effects of speed and propulsive force on joint power generation in walking.

Authors:  Michael G Browne; Jason R Franz
Journal:  J Biomech       Date:  2017-02-21       Impact factor: 2.712

5.  The accuracy of the use of functional hip motions on localization of the center of the hip.

Authors:  Andrew D Speirs; Daniel L Benoit; Mélanie L Beaulieu; Mario Lamontagne; Paul E Beaulé
Journal:  HSS J       Date:  2012-09-07

6.  In vitro validation and reliability study of electromagnetic skin sensors for evaluation of end range of motion positions of the hip.

Authors:  E A Audenaert; L Vigneron; T Van Hoof; K D'Herde; G van Maele; D Oosterlinck; C Pattyn
Journal:  Med Biol Eng Comput       Date:  2011-07-13       Impact factor: 2.602

7.  Biomechanical effects of augmented ankle power output during human walking.

Authors:  Sarah N Fickey; Michael G Browne; Jason R Franz
Journal:  J Exp Biol       Date:  2018-11-16       Impact factor: 3.312

8.  The motor repertoire of older adult fallers may constrain their response to balance perturbations.

Authors:  Jessica L Allen; Jason R Franz
Journal:  J Neurophysiol       Date:  2018-08-22       Impact factor: 2.714

9.  Hip joint center localisation: A biomechanical application to hip arthroplasty population.

Authors:  Vicky Bouffard; Mickael Begon; Annick Champagne; Payam Farhadnia; Pascal-André Vendittoli; Martin Lavigne; François Prince
Journal:  World J Orthop       Date:  2012-08-18

10.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

Authors:  Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti
Journal:  BMC Musculoskelet Disord       Date:  2010-08-31       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.