First Turkish experience with the MicroMed DeBakey VAD.

Deniz Suha Kucukaksu1, Erol Sener, Akif Undar, George P Noon, Oguz Tasdemir.   

Abstract

Mechanical bridging to cardiac transplantation with a ventricular assist device may be a life-saving procedure for patients with end-stage heart failure. Here we report our 3 cases of patients implanted with the MicroMed DeBakey VAD (ventricular assist device). Three male patients, aged 37, 41, and 40, had end-stage left heart failure due to idiopathic cardiomyopathy and were listed for cardiac transplantation. They had progressive hemodynamic deterioration. Although Patient 1 underwent surgery, after device implantation, for bowel necrosis caused by thromboemboli of unknown origin, heart transplantation was performed 70 days after implantation. Pump thrombosis occurred in Patient 2 on the 120th day. Outflow graft ligation was performed because the patient refused a pump exchange. This patient died on the 25th day after ligation and the 145th day after ventricular assist device implantation. A heparin-coated version of the device was implanted in Patient 3, whose preoperative profound biventricular failure had been improved by inotropic medication and intra-aortic balloon pump support. Successful heart transplantation was performed 161 days after implantation. These are the 1st implantations of a left ventricular assist device in Turkey. From these cases, we have learned that the DeBakey VAD supplies adequate blood flow during the bridging period and, due to its simplicity, portability, and low infection rate, enables discharge of the patient from the hospital. However, preoperative psychological evaluation and postoperative psychological support are important for a successful bridging procedure, as is close observation of coagulation and of pump operation.

Entities:  

Mesh:

Year:  2003        PMID: 12809252      PMCID: PMC161896     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  31 in total

1.  Successful reoperation after Batista partial left ventriculectomy demonstrates patient's hemodynamic recovery.

Authors:  O Taşdemir; D S Küçükaksu; O Tarcan; K Vural; E Sener
Journal:  Tex Heart Inst J       Date:  1999

2.  Development of the Baylor Gyro permanently implantable centrifugal blood pump as a biventricular assist device.

Authors:  K Nonaka; J Linneweber; S Ichikawa; M Yoshikawa; S Kawahito; M Mikami; T Motomura; H Ishitoya; I Nishimura; D Oestmann; J Glueck; H Schima; E Wolner; T Shinohara; Y Nosé
Journal:  Artif Organs       Date:  2001-09       Impact factor: 3.094

3.  HeartMate III: pump design for a centrifugal LVAD with a magnetically levitated rotor.

Authors:  K Bourque; D B Gernes; H M Loree; J S Richardson; V L Poirier; N Barletta; A Fleischli; G Foiera; T M Gempp; R Schoeb; K N Litwak; T Akimoto; M J Watach; P Litwak
Journal:  ASAIO J       Date:  2001 Jul-Aug       Impact factor: 2.872

4.  In vivo hemodynamic performance of the Cleveland Clinic CorAide blood pump in calves.

Authors:  Y Ochiai; L A Golding; A L Massiello; A L Medvedev; R L Gerhart; J F Chen; M Takagaki; K Fukamachi
Journal:  Ann Thorac Surg       Date:  2001-09       Impact factor: 4.330

5.  Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device.

Authors:  O H Frazier; E A Rose; Q Macmanus; N A Burton; E A Lefrak; V L Poirier; K A Dasse
Journal:  Ann Thorac Surg       Date:  1992-06       Impact factor: 4.330

Review 6.  Future directions of cardiac assistance.

Authors:  O H Frazier
Journal:  Semin Thorac Cardiovasc Surg       Date:  2000-07

Review 7.  Mechanical cardiac assistance: historical perspectives.

Authors:  O H Frazier
Journal:  Semin Thorac Cardiovasc Surg       Date:  2000-07

Review 8.  Healing the heart with ventricular assist device therapy: mechanisms of cardiac recovery.

Authors:  J B Young
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

9.  First successful Italian clinical experience with DeBakey VAD.

Authors:  S Agati; G Bruschi; C Russo; T Colombo; M Lanfranconi; E Vitali
Journal:  J Heart Lung Transplant       Date:  2001-08       Impact factor: 10.247

10.  Permanent ventricular assist device support versus cardiac transplantation.

Authors:  D G Pennington; T E Oaks; D P Lohmann
Journal:  Ann Thorac Surg       Date:  1999-08       Impact factor: 4.330

View more
  2 in total

1.  Ischemic necrosis of the right colon in a patient with a ventricular assist device system.

Authors:  G Nessar; S Kucukaksu; N I Zengin; O Tasdemir; C Kayaalp
Journal:  Tech Coloproctol       Date:  2007-08-03       Impact factor: 3.781

2.  Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography.

Authors:  Zumrut Tuba Demirozu; Nurcan Arat; Deniz Suha Kucukaksu
Journal:  Cardiovasc J Afr       Date:  2016 Jul/Aug       Impact factor: 1.167

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.