Literature DB >> 11403662

Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics.

J Apel1, R Paul, S Klaus, T Siess, H Reul.   

Abstract

A computational assessment or even quantification of shear induced hemolysis in the predesign phase of artificial organs (e.g., cardiac assist devices) would largely decrease efforts and costs of design and development. In this article, a general approach of hemolysis analysis by means of computational fluid dynamics (CFD) is discussed. A validated computational model of a microaxial blood pump is used for detailed analysis of shear stress distribution. Several methods are presented that allow for a qualitative assessment of shear stress distribution and related exposure times using a Lagrangian approach and mass distribution in combination with shear stress analysis. The results show that CFD offers a convenient tool for the general assessment of shear-induced hemolysis. The determination of critical regions and an estimation of the amount of blood subject to potential damage in relation to the total mass flow are shown to be feasible. However, awareness of limitations and potential flaws in CFD based hemolysis assessments is crucial.

Entities:  

Mesh:

Year:  2001        PMID: 11403662     DOI: 10.1046/j.1525-1594.2001.025005341.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  29 in total

1.  Simulation study of the Hemopump as a cardiac assist device.

Authors:  X Li; J Bai; P He
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

2.  Computational study of the blood flow in three types of 3D hollow fiber membrane bundles.

Authors:  Jiafeng Zhang; Xiaobing Chen; Jun Ding; Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  J Biomech Eng       Date:  2013-12       Impact factor: 2.097

3.  A Multiple Time Stepping Algorithm for Efficient Multiscale Modeling of Platelets Flowing in Blood Plasma.

Authors:  Peng Zhang; Na Zhang; Yuefan Deng; Danny Bluestein
Journal:  J Comput Phys       Date:  2015-03-01       Impact factor: 3.553

4.  Evaluation of a pumping assist lung that uses a rotating fiber bundle.

Authors:  Robert G Svitek; Brian J Frankowski; William J Federspiel
Journal:  ASAIO J       Date:  2005 Nov-Dec       Impact factor: 2.872

5.  Mechanical platelet activation potential in abdominal aortic aneurysms.

Authors:  Kirk B Hansen; Amirhossein Arzani; Shawn C Shadden
Journal:  J Biomech Eng       Date:  2015-02-05       Impact factor: 2.097

6.  Three-dimensional extent of flow stagnation in transcatheter heart valves.

Authors:  Vrishank Raghav; Chris Clifford; Prem Midha; Ikechukwu Okafor; Brian Thurow; Ajit Yoganathan
Journal:  J R Soc Interface       Date:  2019-05-31       Impact factor: 4.118

7.  Utilizing Computational Fluid Dynamics in Cardiovascular Engineering and Medicine-What You Need to Know. Its Translation to the Clinic/Bedside.

Authors:  Danny Bluestein
Journal:  Artif Organs       Date:  2017-02       Impact factor: 3.094

8.  Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices.

Authors:  Angelo Nascimbene; Ruben Hernandez; Joggy K George; Anita Parker; Angela L Bergeron; Subhashree Pradhan; K Vinod Vijayan; Andrew Civitello; Leo Simpson; Maria Nawrot; Vei-Vei Lee; Hari R Mallidi; Reynolds M Delgado; Jing Fei Dong; O H Frazier
Journal:  J Heart Lung Transplant       Date:  2014-01-19       Impact factor: 10.247

9.  Microfluidic emulation of mechanical circulatory support device shear-mediated platelet activation.

Authors:  Annalisa Dimasi; Marco Rasponi; Jawaad Sheriff; Wei-Che Chiu; Danny Bluestein; Phat L Tran; Marvin J Slepian; Alberto Redaelli
Journal:  Biomed Microdevices       Date:  2015-12       Impact factor: 2.838

10.  Hemodynamic and thrombogenic analysis of a trileaflet polymeric valve using a fluid-structure interaction approach.

Authors:  Filippo Piatti; Francesco Sturla; Gil Marom; Jawaad Sheriff; Thomas E Claiborne; Marvin J Slepian; Alberto Redaelli; Danny Bluestein
Journal:  J Biomech       Date:  2015-08-21       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.