Miniature radio-frequency mobility analyzer as a gas chromatographic detector for oxygen-containing volatile organic compounds, pheromones and other insect attractants.

G A Eiceman1, B Tadjikov, E Krylov, E G Nazarov, R A Miller, J Westbrook, P Funk.   

Abstract

A high electric field, radio-frequency ion mobility spectrometry (RF-IMS) analyzer was used as a small detector in gas chromatographic separations of mixtures of volatile organic compounds including alcohols, aldehydes, esters, ethers, pheromones, and other chemical attractants for insects. The detector was equipped with a 2 mCi 63Ni ion source and the drift region for ion characterization was 5 mm wide, 15 mm long and 0.5 mm high. The rate of scanning for the compensation voltages was 60 V s(-1) and permitted four to six scans to be obtained across a capillary chromatographic elution profile for each component. The RF-IMS scans were characteristic of a compound and provided a second dimension of chemical identity to chromatographic retention adding specificity in instances of co-elution. Limits of detection were 1.6-55 x 10(-11) g with an average detection limit for all chemicals of 9.4 x 10(-11) g. Response to mass was linear from 2-50 x 10(-10) g with an average sensitivity of 4 pA ng(-1). Separations of pheromones and chemical attractants for insects illustrated the distinct patterns obtained from gas chromatography with RF-IMS scans in real time and suggest an analytical utility of the RF-IMS as a small, advanced detector for on-site gas chromatographs.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11403471     DOI: 10.1016/s0021-9673(01)00656-2

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  10 in total

1.  Scaling of the resolving power and sensitivity for planar FAIMS and mobility-based discrimination in flow- and field-driven analyzers.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-30       Impact factor: 3.109

2.  Gridless overtone mobility spectrometry.

Authors:  Steven M Zucker; Michael A Ewing; David E Clemmer
Journal:  Anal Chem       Date:  2013-10-14       Impact factor: 6.986

3.  Selection and generation of waveforms for differential mobility spectrometry.

Authors:  Evgeny V Krylov; Stephen L Coy; John Vandermey; Bradley B Schneider; Thomas R Covey; Erkinjon G Nazarov
Journal:  Rev Sci Instrum       Date:  2010-02       Impact factor: 1.523

4.  Modular and reconfigurable gas chromatography / differential mobility spectrometry (GC/DMS) package for detection of volatile organic compounds (VOCs).

Authors:  Ilya M Anishchenko; Mitchell M McCartney; Alexander G Fung; Daniel J Peirano; Michael J Schirle; Nicholas J Kenyon; Cristina E Davis
Journal:  Int J Ion Mobil Spectrom       Date:  2018-08-31

5.  Odour Cues from Fruit Arils of Artocarpus heterophyllus Attract both Sexes of Oriental Fruit Flies.

Authors:  P D Kamala Jayanthi; Parepally Saravan Kumar; Meenal Vyas
Journal:  J Chem Ecol       Date:  2021-04-12       Impact factor: 2.626

6.  Overtone mobility spectrometry: part 2. Theoretical considerations of resolving power.

Authors:  Stephen J Valentine; Sarah T Stokes; Ruwan T Kurulugama; Fabiane M Nachtigall; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2009-01-08       Impact factor: 3.109

7.  Improving FAIMS sensitivity using a planar geometry with slit interfaces.

Authors:  Ridha Mabrouki; Ryan T Kelly; David C Prior; Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2009-06-21       Impact factor: 3.109

8.  Ultrafast differential ion mobility spectrometry at extreme electric fields in multichannel microchips.

Authors:  Alexandre A Shvartsburg; Richard D Smith; Ashley Wilks; Andrew Koehl; David Ruiz-Alonso; Billy Boyle
Journal:  Anal Chem       Date:  2009-08-01       Impact factor: 6.986

9.  The Highs and Lows of FAIMS: Predictions and Future Trends for High Field Asymmetric Waveform Ion Mobility Spectrometry.

Authors:  Yuriy Zrodnikov; Cristina E Davis
Journal:  J Nanomed Nanotechnol       Date:  2012-05-19

10.  Overtone mobility spectrometry: part 1. Experimental observations.

Authors:  Ruwan T Kurulugama; Fabiane M Nachtigall; Sunyoung Lee; Stephen J Valentine; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-06       Impact factor: 3.109

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.