Literature DB >> 19583243

Ultrafast differential ion mobility spectrometry at extreme electric fields in multichannel microchips.

Alexandre A Shvartsburg1, Richard D Smith, Ashley Wilks, Andrew Koehl, David Ruiz-Alonso, Billy Boyle.   

Abstract

The maximum electric field intensity (E) in field asymmetric waveform ion mobility spectrometry (FAIMS) analyses was doubled to E > 60 kV/cm. In earlier devices with >0.5 mm gaps, such strong fields cause electrical breakdown for nearly all gases at ambient pressure. As the Paschen curves are sublinear, thinner gaps permit higher E: here, we established 61 kV/cm in N(2) using microchips with 35 microm gaps. As FAIMS efficiency is exceptionally sensitive to E, such values can in theory accelerate analyses at equal resolution by over an order of magnitude. Here we demonstrate FAIMS filtering in approximately 20 micros or approximately 1% of the previously needed time, with a resolving power of about half that for "macroscopic" units but sufficing for many applications. Microscopic gaps enable concurrent ion processing in multiple (here, 47) channels, which greatly relaxes the charge capacity constraints of planar FAIMS designs. These chips were integrated with a beta-radiation ion source and charge detector. The separation performance is in line with first-principles modeling that accounts for high-field and anisotropic ion diffusion. By extending FAIMS operation into the previously inaccessible field range, the present instrument advances the capabilities for research into ion transport and expands options for separation of hard-to-resolve species.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19583243      PMCID: PMC2947943          DOI: 10.1021/ac900892u

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  33 in total

1.  Elongated conformers of charge states +11 to +15 of bovine ubiquitin studied using ESI-FAIMS-MS.

Authors:  R W Purves; D A Barnett; B Ells; R Guevremont
Journal:  J Am Soc Mass Spectrom       Date:  2001-08       Impact factor: 3.109

2.  Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Authors:  Keqi Tang; Fumin Li; Alexandre A Shvartsburg; Eric F Strittmatter; Richard D Smith
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

3.  Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS).

Authors:  Beata M Kolakowski; Zoltán Mester
Journal:  Analyst       Date:  2007-06-26       Impact factor: 4.616

4.  Scaling of the resolving power and sensitivity for planar FAIMS and mobility-based discrimination in flow- and field-driven analyzers.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-30       Impact factor: 3.109

5.  Characterization of phosphorylated peptides using traveling wave-based and drift cell ion mobility mass spectrometry.

Authors:  Konstantinos Thalassinos; Megan Grabenauer; Susan E Slade; Gillian R Hilton; Michael T Bowers; James H Scrivens
Journal:  Anal Chem       Date:  2009-01-01       Impact factor: 6.986

6.  Optimum waveforms for differential ion mobility spectrometry (FAIMS).

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2008-05-16       Impact factor: 3.109

7.  Miniature differential mobility spectrometry using atmospheric pressure photoionization.

Authors:  Erkinjon G Nazarov; Raanan A Miller; Gary A Eiceman; John A Stone
Journal:  Anal Chem       Date:  2006-07-01       Impact factor: 6.986

8.  Effect of moisture on the field dependence of mobility for gas-phase ions of organophosphorus compounds at atmospheric pressure with field asymmetric ion mobility spectrometry.

Authors:  N Krylova; E Krylov; G A Eiceman; J A Stone
Journal:  J Phys Chem A       Date:  2003-05-15       Impact factor: 2.781

9.  Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics.

Authors:  Jesse D Canterbury; Xianhua Yi; Michael R Hoopmann; Michael J MacCoss
Journal:  Anal Chem       Date:  2008-08-12       Impact factor: 6.986

10.  Differential mobility spectrometry of chlorocarbons with a micro-fabricated drift tube.

Authors:  G A Eiceman; E V Krylov; B Tadjikov; R G Ewing; E G Nazarov; R A Miller
Journal:  Analyst       Date:  2004-02-20       Impact factor: 4.616

View more
  22 in total

1.  Accelerated high-resolution differential ion mobility separations using hydrogen.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  Anal Chem       Date:  2011-11-10       Impact factor: 6.986

2.  Nanospray FAIMS fractionation provides significant increases in proteome coverage of unfractionated complex protein digests.

Authors:  Kristian E Swearingen; Michael R Hoopmann; Richard S Johnson; Ramsey A Saleem; John D Aitchison; Robert L Moritz
Journal:  Mol Cell Proteomics       Date:  2011-12-20       Impact factor: 5.911

3.  A high voltage asymmetric waveform generator for FAIMS.

Authors:  Jesse D Canterbury; James Gladden; Lon Buck; Roy Olund; Michael J MacCoss
Journal:  J Am Soc Mass Spectrom       Date:  2010-02-18       Impact factor: 3.109

4.  Analysis of Supramolecular Complexes of 3-Methylxanthine with Field Asymmetric Waveform Ion Mobility Spectrometry Combined with Mass Spectrometry.

Authors:  Kayleigh L Arthur; Gary A Eiceman; James C Reynolds; Colin S Creaser
Journal:  J Am Soc Mass Spectrom       Date:  2016-02-25       Impact factor: 3.109

5.  Differential ion mobility separations in up to 100% helium using microchips.

Authors:  Alexandre A Shvartsburg; Yehia M Ibrahim; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2014-01-09       Impact factor: 3.109

Review 6.  Size, weight and position: ion mobility spectrometry and imaging MS combined.

Authors:  András Kiss; Ron M A Heeren
Journal:  Anal Bioanal Chem       Date:  2011-01-13       Impact factor: 4.142

7.  Maximizing Ion Transmission in Differential Mobility Spectrometry.

Authors:  Bradley B Schneider; Frank Londry; Erkinjon G Nazarov; Yang Kang; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2017-06-29       Impact factor: 3.109

8.  Increased Ion Transmission for Differential Ion Mobility Combined with Mass Spectrometry by Implementation of a Flared Inlet Capillary.

Authors:  Matthew T Campbell; Gary L Glish
Journal:  J Am Soc Mass Spectrom       Date:  2016-10-17       Impact factor: 3.109

9.  Protein analyses using differential ion mobility microchips with mass spectrometry.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  Anal Chem       Date:  2012-08-13       Impact factor: 6.986

10.  Ultrafast differential ion mobility spectrometry at extreme electric fields coupled to mass spectrometry.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith; Martin Holden; Martyn Rush; Andrew Thompson; Danielle Toutoungi
Journal:  Anal Chem       Date:  2009-10-01       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.