Literature DB >> 11382583

The Otologics MET ossicular stimulator.

J F Kasic1, J M Fredrickson.   

Abstract

The advent of various technologies for middle ear implants (MEI) that directly stimulate the ossicles has created a new therapy for hearing loss and a new segment of the medical device industry. Benefits can be established when the MEI is compared with the best alternative currently available. Otologics, LLC, has developed an electromechanical MEI (middle ear transducer (MET) Ossicular Stimulator) designed to aid individuals with moderately severe to severe sensorineural hearing loss. The efficacy of the device is determined through a clinical comparison of the MET Ossicular Stimulator to that of a state-of-the-art digital hearing aid.

Entities:  

Mesh:

Year:  2001        PMID: 11382583     DOI: 10.1016/s0030-6665(05)70345-5

Source DB:  PubMed          Journal:  Otolaryngol Clin North Am        ISSN: 0030-6665            Impact factor:   3.346


  17 in total

1.  Controlling the position and the dislocation of the middle ear transducer with high-resolution computed tomography and digital volume tomography: implications for the transducers' design.

Authors:  Georgios Kontorinis; Anja M Giesemann; Thomas Witt; Friedrich Goetz; Burkard Schwab
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-09-22       Impact factor: 2.503

2.  [Active middle ear implants: more than "just" a hearing aid].

Authors:  M Praetorius
Journal:  HNO       Date:  2007-09       Impact factor: 1.284

Review 3.  [Semi-implantable hearing aids for sensorineural hearing loss and combined hearing loss: experiences at the German Armed Forces Hospital in Ulm].

Authors:  M Tisch; H Maier
Journal:  HNO       Date:  2009-03       Impact factor: 1.284

4.  Round window membrane implantation with an active middle ear implant: a study of the effects on the performance of round window exposure and transducer tip diameter in human cadaveric temporal bones.

Authors:  Stéphane Tringali; Kanthaiah Koka; Arnaud Deveze; N Julian Holland; Herman A Jenkins; Daniel J Tollin
Journal:  Audiol Neurootol       Date:  2010-02-11       Impact factor: 1.854

5.  Otologics Middle Ear Transducer™ (MET™) Implantable Hearing Device: Rationale, Technology, and Design Strategies.

Authors:  A U Bankaitis; John M Fredrickson
Journal:  Trends Amplif       Date:  2002-06

6.  Mastoidectomy dimensions for direct acoustic cochlear implantation: a human cadaveric temporal bone study.

Authors:  Francesco Fiorino; Maurizio Amadori
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-02-28       Impact factor: 2.503

Review 7.  Congenital hearing loss.

Authors:  Anna M H Korver; Richard J H Smith; Guy Van Camp; Mark R Schleiss; Maria A K Bitner-Glindzicz; Lawrence R Lustig; Shin-Ichi Usami; An N Boudewyns
Journal:  Nat Rev Dis Primers       Date:  2017-01-12       Impact factor: 52.329

8.  Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary surgical and clinical results.

Authors:  L Bruschini; F Forli; A Santoro; P Bruschini; S Berrettini
Journal:  Acta Otorhinolaryngol Ital       Date:  2009-04       Impact factor: 2.124

Review 9.  Middle ear implantable hearing devices: an overview.

Authors:  David S Haynes; Jadrien A Young; George B Wanna; Michael E Glasscock
Journal:  Trends Amplif       Date:  2009-09

10.  The Carina© middle ear implant: surgical and functional outcomes.

Authors:  Luca Bruschini; Stefano Berrettini; Francesca Forli; Alessandra Murri; Domenico Cuda
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-03-23       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.