Literature DB >> 35528228

Development of Dual-Frequency PMUT Arrays Based on Thin Ceramic PZT for Endoscopic Photoacoustic Imaging.

Haoran Wang1, Hao Yang2, Zhenfang Chen3, Qincheng Zheng4, Huabei Jiang2, Philip X-L Feng1, Huikai Xie4.   

Abstract

This paper presents a dual-frequency piezoelectric micromachined ultrasonic transducer (pMUT) array based on thin ceramic PZT for endoscopic photoacoustic imaging (PAI) applications. With a chip size of 7 × 7 mm2, the pMUT array consists of 256 elements, half of which have a lower resonant frequency of 1.2 MHz and the other half have a higher resonant frequency of 3.4 MHz. Ceramic PZT, with outstanding piezoelectric coefficients, has been successfully thinned down to a thickness of only 4 μ by using wafer bonding and chemical mechanical polishing (CMP) techniques and employed as the piezoelectric layer of the pMUT elements. The diaphragm diameters of the lower-frequency and higher-frequency elements are 220 μm and 120 μm, respectively. The design methodology, multiphysics modeling, fabrication process, and characterization of the pMUTs are presented in detail. The fabricated pMUT array has been fully characterized via electrical, mechanical, and acoustic measurements. The measured maximum responsivities of the lower- and higher- frequency elements reach 110 nm/V and 30 nm/V at their respective resonances. The measured cross-couplings of the lower-frequency elements and higher-frequency elements are about 9% and 5%, respectively. Furthermore, PAI experiments with pencil leads embedded into an agar phantom have been conducted, which clearly shows the advantages of using dual-frequency pMUT arrays to provide comprehensive photoacoustic images with high spatial resolution and large signal-to-noise ratio simultaneously.

Entities:  

Keywords:  Microelectromechanical systems (MEMS); ceramic PZT; dual-frequency; endoscopic imaging; pMUT arrays; photoacoustic imaging (PAI); piezoelectric micromachined ultrasonic transducers (pMUTs)

Year:  2021        PMID: 35528228      PMCID: PMC9075345          DOI: 10.1109/jmems.2021.3096733

Source DB:  PubMed          Journal:  J Microelectromech Syst        ISSN: 1057-7157            Impact factor:   2.829


  26 in total

1.  Piezoelectric micromachined ultrasonic transducers based on PZT thin films.

Authors:  Paul Muralt; Nicolas Ledermann; Jacek Baborowski; Abdolghaffar Barzegar; Sandrine Gentil; Brahim Belgacem; Sylvain Petitgrand; Alain Bosseboeuf; Nava Setter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

Review 2.  Photoacoustic tomography: in vivo imaging from organelles to organs.

Authors:  Lihong V Wang; Song Hu
Journal:  Science       Date:  2012-03-23       Impact factor: 47.728

Review 3.  Photoacoustic endoscopy: A progress review.

Authors:  Heng Guo; Ying Li; Weizhi Qi; Lei Xi
Journal:  J Biophotonics       Date:  2020-10-01       Impact factor: 3.207

4.  Photoacoustic Brain Imaging: from Microscopic to Macroscopic Scales.

Authors:  Junjie Yao; Lihong V Wang
Journal:  Neurophotonics       Date:  2014-05-28       Impact factor: 3.593

5.  Array Design of Piezoelectric Micromachined Ultrasonic Transducers With Low-Crosstalk and High-Emission Performance.

Authors:  Tingzhong Xu; Libo Zhao; Zhuangde Jiang; Shuaishuai Guo; Zhikang Li; Ping Yang; Lin Sun; Guoxi Luo; Liangchi Zhang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-11-28       Impact factor: 2.725

6.  Transparent capacitive micromachined ultrasonic transducer (CMUT) arrays for real-time photoacoustic applications.

Authors:  Afshin Kashani Ilkhechi; Christopher Ceroici; Zhenhao Li; Roger Zemp
Journal:  Opt Express       Date:  2020-04-27       Impact factor: 3.894

7.  A Ceramic PZT-based PMUT Array for Endoscopic Photoacoustic Imaging.

Authors:  Haoran Wang; Zhenfang Chen; Hao Yang; Huabei Jiang; Huikai Xie
Journal:  J Microelectromech Syst       Date:  2020-07-28       Impact factor: 2.417

8.  High resolution functional photoacoustic tomography of breast cancer.

Authors:  Xiaoqi Li; Coy D Heldermon; Lei Yao; Lei Xi; Huabei Jiang
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

Review 9.  Light in and sound out: emerging translational strategies for photoacoustic imaging.

Authors:  S Zackrisson; S M W Y van de Ven; S S Gambhir
Journal:  Cancer Res       Date:  2014-02-10       Impact factor: 12.701

10.  Single-breath-hold photoacoustic computed tomography of the breast.

Authors:  Li Lin; Peng Hu; Junhui Shi; Catherine M Appleton; Konstantin Maslov; Lei Li; Ruiying Zhang; Lihong V Wang
Journal:  Nat Commun       Date:  2018-06-15       Impact factor: 14.919

View more
  1 in total

1.  Development of Dual-Frequency PMUT Arrays Based on Thin Ceramic PZT for Endoscopic Photoacoustic Imaging.

Authors:  Haoran Wang; Hao Yang; Zhenfang Chen; Qincheng Zheng; Huabei Jiang; Philip X-L Feng; Huikai Xie
Journal:  J Microelectromech Syst       Date:  2021-07-26       Impact factor: 2.829

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.