Literature DB >> 11373221

Percutaneous retrieval of lost or misplaced intravascular objects.

A Gabelmann1, S Kramer, J Gorich.   

Abstract

OBJECTIVE: We report on our experience with percutaneous interventional techniques for retrieval of intravascular foreign bodies or repositioning of misplaced endovascular prostheses.
MATERIALS AND METHODS: Over a period of 6 years, we attempted percutaneous treatment of intravascular foreign bodies in 45 patients. The 45 foreign objects consisted of 12 endovascular stents, 14 catheter fragments, 11 embolization coils, four guidewire fragments, three vena cava filters, and one cardiac valve fragment. Percutaneous extraction was performed using a combination of multipurpose catheters and nitinol snare loop or grasping forceps. Depending on their composition, misplaced or dislodged intravascular stents were either repositioned or percutaneously removed.
RESULTS: Percutaneous intervention was successful in 41 (91.1%) of 45 patients. Of 38 patients on whom we performed percutaneous removal, the procedure was successful in 34 patients (89.5%), including 13 of the 14 patients with catheter fragments, all four of the patients with guidewire fragments, 10 of the 11 patients with misplaced or dislodged embolization coils, four of the five patients with misplaced or dislodged endovascular stents, and all three of the patients with misplaced or dislodged vena cava filters. The procedure was not successful in the one patient with a cardiac valve fragment. All seven of the percutaneous repositioning procedures we performed resulted in the endovascular stent being successfully repositioned in a stable intravascular position. Most of the retrieval procedures (77.7%) were performed using the nitinol snare as the primary instrument. No late complications were registered during the follow-up period, which ranged from 9 to 68 months (mean, 42.4 months overall).
CONCLUSION: Percutaneous techniques for the extraction of intravascular foreign objects or for repositioning of dislocated endovascular stents are highly effective with a low rate of complications and should always be the primary method of choice.

Entities:  

Mesh:

Year:  2001        PMID: 11373221     DOI: 10.2214/ajr.176.6.1761509

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  31 in total

1.  The balloon retriever technique.

Authors:  M Schumacher; A Berlis
Journal:  Neuroradiology       Date:  2003-03-12       Impact factor: 2.804

2.  A case of missing mitral valve leaflet: radiological detection.

Authors:  Altan Yildiz; Caner Ozer; Engin Kara; F Demir Apaydin; Meltem Nass Duce; Hulusi Eğilmez
Journal:  Eur Radiol       Date:  2003-02-18       Impact factor: 5.315

3.  The retrieval of the diagnostic catheter which broke and embolised twice.

Authors:  I B Vijayalakshmi; Navin Agrawal; Kavya Mallikarjun; C N Manjunath
Journal:  BMJ Case Rep       Date:  2013-07-24

4.  The lost coil.

Authors:  J M B L van Remmen; P H Haarbrink; B T J Meursing
Journal:  Neth Heart J       Date:  2004-04       Impact factor: 2.380

5.  Unintentionally retained vascular devices: improving recognition and removal.

Authors:  Gilbert Whang; Ilya Lekht; Rita Krane; Greg Peters; Suzanne L Palmer
Journal:  Diagn Interv Radiol       Date:  2017 May-Jun       Impact factor: 2.630

6.  Minimally invasive retrieval of patent foramen ovale closure device after device migration to the descending aorta.

Authors:  Abhijeet S Basoor; John F Cotant; Abdul R Halabi; Michele DeGregorio; Haroon Chughtai; Kiritkumar C Patel
Journal:  Tex Heart Inst J       Date:  2012

7.  A Novel Approach for the Retrieval of Broken Catheter Fragment - Using Balloon Dilatation Technique.

Authors:  Padmakumar Ramachandran; Rohith Poondru Reddy; M Sudhakar Rao; Ashwal Adamane Jayaram
Journal:  J Clin Diagn Res       Date:  2016-03-01

8.  The successful withdrawal of a migrated central venous catheter.

Authors:  Hassan Zamani; Kazem Babazadeh; Rahman Ghaffari; Hossein Karami; Saeid Fattahi; Farzad Mokhtari Esbuie
Journal:  Caspian J Intern Med       Date:  2012

9.  Foreign body removal by snare loop: during intracranial stent procedure.

Authors:  Yul Oh; Dae Hyun Hwang; Young Hwan Ko; Ik Won Kang; In Soo Kim; Choon Woong Hur
Journal:  Neurointervention       Date:  2012-02-29

Review 10.  Intravascular foreign bodies: danger of unretrieved fragmented medical devices.

Authors:  Minori Tateishi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

View more