Literature DB >> 12687314

The balloon retriever technique.

M Schumacher1, A Berlis.   

Abstract

We report a 50-year-old woman with a large supraophthalmic aneurysm. An attempt was made to treat this by endovascular occlusion of the distal internal carotid artery with coils but they could not be placed satisfactorily. During withdrawal a coil became stuck, stretched and finally detached inside the guiding catheter. It was salvaged easily with a balloon retriever technique. This seems to be a useful way to remove stretched coils.

Entities:  

Mesh:

Year:  2003        PMID: 12687314     DOI: 10.1007/s00234-003-0956-6

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  9 in total

1.  Percutaneous vascular foreign body retrieval: experience of an 11-year period.

Authors:  R F Dondelinger; B Lepoutre; J C Kurdziel
Journal:  Eur J Radiol       Date:  1991 Jan-Feb       Impact factor: 3.528

2.  Dual microcatheter and guidewire snare technique for retrieval of intravascular foreign body: technical note.

Authors:  T Terada; H Matsumoto; Y Nakamura; Y Kinoshita; E Nakai; K Nakai; T Itakura
Journal:  Neuroradiology       Date:  1996-10       Impact factor: 2.804

3.  Experience with new retrieval forceps for foreign body removal in the vascular, urinary, and biliary systems.

Authors:  J B Selby; C J Tegtmeyer; G M Bittner
Journal:  Radiology       Date:  1990-08       Impact factor: 11.105

4.  An endovascular retrieving device for use in small vessels.

Authors:  V B Graves; A H Rappe; T P Smith; I Sepetka; A Ahuja; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  1993 Jul-Aug       Impact factor: 3.825

5.  Microcatheter retrieval device for intravascular foreign body removal.

Authors:  T P Smith; V B Graves; V V Halbach; R T Higashida; K W Fraser; C F Dowd; G B Hieshima
Journal:  AJNR Am J Neuroradiol       Date:  1993 Jul-Aug       Impact factor: 3.825

6.  Percutaneous retrieval of lost or misplaced intravascular objects.

Authors:  A Gabelmann; S Kramer; J Gorich
Journal:  AJR Am J Roentgenol       Date:  2001-06       Impact factor: 3.959

7.  Intravascular foreign bodies: percutaneous retrieval.

Authors:  R Uflacker; S Lima; A C Melichar
Journal:  Radiology       Date:  1986-09       Impact factor: 11.105

8.  Retrieval of intravascular foreign bodies: experience in 32 cases.

Authors:  T K Egglin; K W Dickey; M Rosenblatt; J S Pollak
Journal:  AJR Am J Roentgenol       Date:  1995-05       Impact factor: 3.959

9.  Percutaneous retrieval of foreign bodies: experience with the nitinol Goose Neck snare.

Authors:  S Cekirge; J P Weiss; R G Foster; H L Neiman; G K McLean
Journal:  J Vasc Interv Radiol       Date:  1993 Nov-Dec       Impact factor: 3.464

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.