Literature DB >> 24009933

The successful withdrawal of a migrated central venous catheter.

Hassan Zamani1, Kazem Babazadeh, Rahman Ghaffari, Hossein Karami, Saeid Fattahi, Farzad Mokhtari Esbuie.   

Abstract

BACKGROUND: Central venous catheters (CVCs) have been used widely in clinics. These catheters are also recommended for children and infants receiving chemotherapy and total parenteral nutrition (TPN) and etc. In this paper, we present migrated fractured control line of the heart of a girl. CASE
PRESENTATION: A 2.5 year old girl with migrated of the fractured central line into the heart. In the catheterization laboratory, first we placed a long sheath (8 F) into the inferior vena cava via femoral vein and then trapped the foreign body by pigtail catheter and wire 0.035 inch and pulled it down to make its proximal free. After that, we snared the catheter by snare-catheter and pulled it into the femoral vein, and then the cardiac surgeon bridged it out by cut-down successfully.
CONCLUSION: A rare complication in the use of central catheters is fraction and cardiac embolization. We offer gentle bringing out of the catheter lines under fluoroscopy guide in all of the cases, if this is technically possible and safe.

Entities:  

Keywords:  Cardiac embolization; Central Venous Catheter; Foreign body; Snare

Year:  2012        PMID: 24009933      PMCID: PMC3755866     

Source DB:  PubMed          Journal:  Caspian J Intern Med        ISSN: 2008-6164


  20 in total

1.  NON-SURGICAL RETRIEVAL OF A BROKEN SEGMENT OF STEEL SPRING GUIDE FROM THE RIGHT ATRIUM AND INFERIOR VENA CAVA.

Authors:  J THOMAS; B SINCLAIR-SMITH; D BLOOMFIELD; A DAVACHI
Journal:  Circulation       Date:  1964-07       Impact factor: 29.690

Review 2.  Complications of central venous catheterization.

Authors:  Roberto E Kusminsky
Journal:  J Am Coll Surg       Date:  2007-04       Impact factor: 6.113

3.  Intravenous catheter emboli. Experience with twenty cases and collective review.

Authors:  J D Richardson; F L Grover; J K Trinkle
Journal:  Am J Surg       Date:  1974-12       Impact factor: 2.565

4.  Transluminal extraction of catheter and guide fragments from the heart and great vessels; 29 collected cases.

Authors:  C T Dotter; J Rösch; M K Bilbao
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1971-03

5.  Percutaneous retrieval of a broken umbilical catheter from left atrium in a premature newborn.

Authors:  C E Ruiz; G A Nystrom; A I Butt; H P Zhang
Journal:  Cathet Cardiovasc Diagn       Date:  1995-11

6.  Percutaneous retrieval of lost or misplaced intravascular objects.

Authors:  A Gabelmann; S Kramer; J Gorich
Journal:  AJR Am J Roentgenol       Date:  2001-06       Impact factor: 3.959

7.  Retrieval of intravascular foreign bodies: experience in 32 cases.

Authors:  T K Egglin; K W Dickey; M Rosenblatt; J S Pollak
Journal:  AJR Am J Roentgenol       Date:  1995-05       Impact factor: 3.959

8.  Successful percutaneous retrieval of an intracardiac catheter fragment in an 800-g premature infant.

Authors:  Tina Young; Robert E Shaddy
Journal:  J Perinatol       Date:  2003-01       Impact factor: 2.521

9.  Percutaneous retrieval of foreign bodies: experience with the nitinol Goose Neck snare.

Authors:  S Cekirge; J P Weiss; R G Foster; H L Neiman; G K McLean
Journal:  J Vasc Interv Radiol       Date:  1993 Nov-Dec       Impact factor: 3.464

10.  Nitinol gooseneck snare for removal of foreign bodies: experimental study and clinical evaluation.

Authors:  J W Yedlicka; J E Carlson; D W Hunter; W R Castañeda-Zúñiga; K Amplatz
Journal:  Radiology       Date:  1991-03       Impact factor: 11.105

View more
  2 in total

1.  A Novel Two-Step Technique for Retrieving Fractured Peripherally Inserted Central Catheter Segments Migrating into the Heart or the Pulmonary Artery.

Authors:  Juan Peng; Xiao-Ming Zhang; Lin Yang; Hao Xu; Nan-Dong Miao; Yong-Jun Ren; Kang Liu; Xu-Li Min; Ke Yang; Shi Yang; Cheng Yang
Journal:  Biomed Res Int       Date:  2016-08-23       Impact factor: 3.411

2.  Device fracture as a potential complication of a left ventricular microaxial pump catheter: a case report.

Authors:  Mirza Mutallimov; Fikret Er; Natig Gassanov
Journal:  Eur Heart J Case Rep       Date:  2022-08-16
  2 in total