The standard deviation in fluorescence correlation spectroscopy.

T Wohland1, R Rigler, H Vogel.   

Abstract

The standard deviation (SD) in fluorescence correlation spectroscopy (FCS) has been mostly neglected in applications. However, the knowledge of the correct SD is necessary for an accurate data evaluation, especially when fitting theoretical models to experimental data. In this work, an algorithm is presented that considers the essential features of FCS. It allows prediction of the performance of FCS measurements in various cases, which is important for finding optimal experimental conditions. The program calculates the SD of the experimental autocorrelation function online. This procedure leads to improved parameter estimation, compared to currently used theoretical approximations for the SD. Three methods for the calculation of the SD are presented and compared to earlier analytical solutions (D. E. Koppel. 1974. Phys. Rev. A. 10:1938-1945.), calculation directly from fluorescence intensity values, by averaging several FCS measurements, or by dividing one measurement into a set of shorter data packages. Although the averaging over several measurements yields accurate estimates for the SD, the other two methods are considerably less time consuming, can be run online, and yield comparable results.

Entities:  

Mesh:

Year:  2001        PMID: 11371471      PMCID: PMC1301482          DOI: 10.1016/S0006-3495(01)76264-9

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  11 in total

1.  The photon counting histogram in fluorescence fluctuation spectroscopy.

Authors:  Y Chen; J D Müller; P T So; E Gratton
Journal:  Biophys J       Date:  1999-07       Impact factor: 4.033

2.  Quantitative characterization of the binding of fluorescently labeled colchicine to tubulin in vitro using fluorescence correlation spectroscopy.

Authors:  E Van Craenenbroeck; Y Engelborghs
Journal:  Biochemistry       Date:  1999-04-20       Impact factor: 3.162

3.  On the statistics of fluorescence correlation spectroscopy.

Authors:  H Qian
Journal:  Biophys Chem       Date:  1990-10       Impact factor: 2.352

4.  Use of weighting functions in data fitting.

Authors:  E Di Cera
Journal:  Methods Enzymol       Date:  1992       Impact factor: 1.600

5.  Confocal fluorescence coincidence analysis: an approach to ultra high-throughput screening.

Authors:  T Winkler; U Kettling; A Koltermann; M Eigen
Journal:  Proc Natl Acad Sci U S A       Date:  1999-02-16       Impact factor: 11.205

6.  Site-specific interaction of thrombin and inhibitors observed by fluorescence correlation spectroscopy.

Authors:  J Klingler; T Friedrich
Journal:  Biophys J       Date:  1997-10       Impact factor: 4.033

Review 7.  Fluorescence correlation spectroscopy (FCS)--a highly sensitive method to analyze drug/target interactions.

Authors:  S Sterrer; K Henco
Journal:  J Recept Signal Transduct Res       Date:  1997 Jan-May       Impact factor: 2.092

8.  Study of ligand-receptor interactions by fluorescence correlation spectroscopy with different fluorophores: evidence that the homopentameric 5-hydroxytryptamine type 3As receptor binds only one ligand.

Authors:  T Wohland; K Friedrich; R Hovius; H Vogel
Journal:  Biochemistry       Date:  1999-07-06       Impact factor: 3.162

9.  Fluorescence correlation spectrometry of the interaction kinetics of tetramethylrhodamin alpha-bungarotoxin with Torpedo californica acetylcholine receptor.

Authors:  B Rauer; E Neumann; J Widengren; R Rigler
Journal:  Biophys Chem       Date:  1996-01-16       Impact factor: 2.352

10.  Marrow transplantation for juvenile osteopetrosis.

Authors:  M Sorell; N Kapoor; D Kirkpatrick; J F Rosen; R S Chaganti; C Lopez; B Dupont; M S Pollack; B N Terrin; M B Harris; D Vine; J S Rose; C Goossen; J Lane; R A Good; R J O'Reilly
Journal:  Am J Med       Date:  1981-06       Impact factor: 4.965

View more
  70 in total

1.  Statistical analysis of fluorescence correlation spectroscopy: the standard deviation and bias.

Authors:  Saveez Saffarian; Elliot L Elson
Journal:  Biophys J       Date:  2003-03       Impact factor: 4.033

2.  Measuring size distribution in highly heterogeneous systems with fluorescence correlation spectroscopy.

Authors:  Parijat Sengupta; K Garai; J Balaji; N Periasamy; S Maiti
Journal:  Biophys J       Date:  2003-03       Impact factor: 4.033

3.  Analysis of coupled bimolecular reaction kinetics and diffusion by two-color fluorescence correlation spectroscopy: enhanced resolution of kinetics by resonance energy transfer.

Authors:  Erik F Y Hom; A S Verkman
Journal:  Biophys J       Date:  2002-07       Impact factor: 4.033

4.  Ligand-receptor kinetics measured by total internal reflection with fluorescence correlation spectroscopy.

Authors:  Alena M Lieto; Randall C Cush; Nancy L Thompson
Journal:  Biophys J       Date:  2003-11       Impact factor: 4.033

5.  Simulation of single-molecule trapping in a nanochannel.

Authors:  William Neil Robinson; Lloyd M Davis
Journal:  J Biomed Opt       Date:  2010 Jul-Aug       Impact factor: 3.170

6.  Kinetics of insulin adsorption at the oil-water interface and diffusion properties of adsorbed layers monitored using fluorescence correlation spectroscopy.

Authors:  Jesper Donsmark; Lene Jorgensen; Susanne Mollmann; Sven Frokjaer; Christian Rischel
Journal:  Pharm Res       Date:  2006-11-30       Impact factor: 4.200

7.  Sampling effects, noise, and photobleaching in temporal image correlation spectroscopy.

Authors:  David L Kolin; Santiago Costantino; Paul W Wiseman
Journal:  Biophys J       Date:  2005-10-28       Impact factor: 4.033

8.  Global analysis of fluorescence fluctuation data.

Authors:  Victor V Skakun; Mark A Hink; Anatoli V Digris; Ruchira Engel; Eugene G Novikov; Vladimir V Apanasovich; Antonie J W G Visser
Journal:  Eur Biophys J       Date:  2005-02-12       Impact factor: 1.733

9.  Fluorescence correlation spectroscopy diffusion laws to probe the submicron cell membrane organization.

Authors:  Laure Wawrezinieck; Hervé Rigneault; Didier Marguet; Pierre-François Lenne
Journal:  Biophys J       Date:  2005-09-30       Impact factor: 4.033

10.  Accuracy and dynamic range of spatial image correlation and cross-correlation spectroscopy.

Authors:  Santiago Costantino; Jonathan W D Comeau; David L Kolin; Paul W Wiseman
Journal:  Biophys J       Date:  2005-05-27       Impact factor: 4.033

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.