Literature DB >> 10388780

The photon counting histogram in fluorescence fluctuation spectroscopy.

Y Chen1, J D Müller, P T So, E Gratton.   

Abstract

Fluorescence correlation spectroscopy (FCS) is generally used to obtain information about the number of fluorescent particles in a small volume and the diffusion coefficient from the autocorrelation function of the fluorescence signal. Here we demonstrate that photon counting histogram (PCH) analysis constitutes a novel tool for extracting quantities from fluorescence fluctuation data, i.e., the measured photon counts per molecule and the average number of molecules within the observation volume. The photon counting histogram of fluorescence fluctuation experiments, in which few molecules are present in the excitation volume, exhibits a super-Poissonian behavior. The additional broadening of the PCH compared to a Poisson distribution is due to fluorescence intensity fluctuations. For diffusing particles these intensity fluctuations are caused by an inhomogeneous excitation profile and the fluctuations in the number of particles in the observation volume. The quantitative relationship between the detected photon counts and the fluorescence intensity reaching the detector is given by Mandel's formula. Based on this equation and considering the fluorescence intensity distribution in the two-photon excitation volume, a theoretical expression for the PCH as a function of the number of molecules in the excitation volume is derived. For a single molecular species two parameters are sufficient to characterize the histogram completely, namely the average number of molecules within the observation volume and the detected photon counts per molecule per sampling time epsilon. The PCH for multiple molecular species, on the other hand, is generated by successively convoluting the photon counting distribution of each species with the others. The influence of the excitation profile upon the photon counting statistics for two relevant point spread functions (PSFs), the three-dimensional Gaussian PSF conventionally employed in confocal detection and the square of the Gaussian-Lorentzian PSF for two photon excitation, is explicitly treated. Measured photon counting distributions obtained with a two-photon excitation source agree, within experimental error with the theoretical PCHs calculated for the square of a Gaussian-Lorentzian beam profile. We demonstrate and discuss the influence of the average number of particles within the observation volume and the detected photon counts per molecule per sampling interval upon the super-Poissonian character of the photon counting distribution.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10388780      PMCID: PMC1300352          DOI: 10.1016/S0006-3495(99)76912-2

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  18 in total

1.  Oscillation and noise determine signal transduction in shark multimodal sensory cells.

Authors:  H A Braun; H Wissing; K Schäfer; M C Hirsch
Journal:  Nature       Date:  1994-01-20       Impact factor: 49.962

2.  Motion of myosin fragments during actin-activated ATPase: fluorescence correlation spectroscopy study.

Authors:  J Borejdo
Journal:  Biopolymers       Date:  1979-11       Impact factor: 2.505

3.  Distribution of molecular aggregation by analysis of fluctuation moments.

Authors:  H Qian; E L Elson
Journal:  Proc Natl Acad Sci U S A       Date:  1990-07       Impact factor: 11.205

Review 4.  Sorting single molecules: application to diagnostics and evolutionary biotechnology.

Authors:  M Eigen; R Rigler
Journal:  Proc Natl Acad Sci U S A       Date:  1994-06-21       Impact factor: 11.205

5.  Dynamics of fluorescence marker concentration as a probe of mobility.

Authors:  D E Koppel; D Axelrod; J Schlessinger; E L Elson; W W Webb
Journal:  Biophys J       Date:  1976-11       Impact factor: 4.033

6.  High-order fluorescence fluctuation analysis of model protein clusters.

Authors:  A G Palmer; N L Thompson
Journal:  Proc Natl Acad Sci U S A       Date:  1989-08       Impact factor: 11.205

7.  Fluorescence correlation spectroscopy for detecting submicroscopic clusters of fluorescent molecules in membranes.

Authors:  A G Palmer; N L Thompson
Journal:  Chem Phys Lipids       Date:  1989-06       Impact factor: 3.329

8.  Fluorescence correlation spectroscopy. II. An experimental realization.

Authors:  D Magde; E L Elson; W W Webb
Journal:  Biopolymers       Date:  1974-01       Impact factor: 2.505

9.  Scanning concentration correlation spectroscopy using the confocal laser microscope.

Authors:  D E Koppel; F Morgan; A E Cowan; J H Carson
Journal:  Biophys J       Date:  1994-02       Impact factor: 4.033

10.  Molecular aggregation characterized by high order autocorrelation in fluorescence correlation spectroscopy.

Authors:  A G Palmer; N L Thompson
Journal:  Biophys J       Date:  1987-08       Impact factor: 4.033

View more
  210 in total

1.  Molecular heterogeneity of O-acetylserine sulfhydrylase by two-photon excited fluorescence fluctuation spectroscopy.

Authors:  G Chirico; S Bettati; A Mozzarelli; Y Chen; J D Müller; E Gratton
Journal:  Biophys J       Date:  2001-04       Impact factor: 4.033

2.  Resolving heterogeneity on the single molecular level with the photon-counting histogram.

Authors:  J D Müller; Y Chen; E Gratton
Journal:  Biophys J       Date:  2000-01       Impact factor: 4.033

3.  Total internal reflection with fluorescence correlation spectroscopy: combined surface reaction and solution diffusion.

Authors:  T E Starr; N L Thompson
Journal:  Biophys J       Date:  2001-03       Impact factor: 4.033

4.  Fluorescence intensity multiple distributions analysis: concurrent determination of diffusion times and molecular brightness.

Authors:  K Palo; U Mets; S Jäger; P Kask; K Gall
Journal:  Biophys J       Date:  2000-12       Impact factor: 4.033

5.  Probing ligand protein binding equilibria with fluorescence fluctuation spectroscopy.

Authors:  Y Chen; J D Müller; S Y Tetin; J D Tyner; E Gratton
Journal:  Biophys J       Date:  2000-08       Impact factor: 4.033

6.  Sensitivity enhancement in fluorescence correlation spectroscopy of multiple species using time-gated detection.

Authors:  D C Lamb; A Schenk; C Röcker; C Scalfi-Happ; G U Nienhaus
Journal:  Biophys J       Date:  2000-08       Impact factor: 4.033

7.  Molecular brightness characterization of EGFP in vivo by fluorescence fluctuation spectroscopy.

Authors:  Yan Chen; Joachim D Müller; QiaoQiao Ruan; Enrico Gratton
Journal:  Biophys J       Date:  2002-01       Impact factor: 4.033

8.  The standard deviation in fluorescence correlation spectroscopy.

Authors:  T Wohland; R Rigler; H Vogel
Journal:  Biophys J       Date:  2001-06       Impact factor: 4.033

9.  Fluorescence correlation spectroscopy close to a fluctuating membrane.

Authors:  Cécile Fradin; Asmahan Abu-Arish; Rony Granek; Michael Elbaum
Journal:  Biophys J       Date:  2003-03       Impact factor: 4.033

10.  Paxillin dynamics measured during adhesion assembly and disassembly by correlation spectroscopy.

Authors:  Michelle A Digman; Claire M Brown; Alan R Horwitz; William W Mantulin; Enrico Gratton
Journal:  Biophys J       Date:  2007-11-09       Impact factor: 4.033

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.