Literature DB >> 24578597

Usefulness of the multiplanar reformatting mode of three-dimensional echocardiography in evaluating valvular and structural heart disease: An experience from Saudi Arabia.

Saad Q Khoshhal1.   

Abstract

OBJECTIVE: The aim of this study is to compare the feasibility and capacity of multiplanar reformatting (MPR) mode of three-dimensional echocardiography (3DE-MPR technique) with two-dimensional echocardiography (2DE) for visualizing morphological details during evaluation of congenital heart disease (CHD). The study also seeks to validate the accuracy of 3DE MPR in determining cardiac valvular lesions and the application of the 3DE-MPR technique in daily clinical practice.
METHODS: A cross-sectional study was carried out at Madinah Cardiac Centre, Saudi Arabia from May to December 2012. Various forms of CHD were diagnosed in 43 patients by conventional 2DE, and the patients were then examined with the 3DE-MPR technique using dedicated software and a standard protocol.
RESULTS: Of the 43 patients, 23 (53.5%) were males and 20 (46.5%) females. Their age varied from 30 days to 146 months (mean age, 70.2 months and SD = 42.5 months) and their weight from 4 to 42 kg (mean weight, 20.2 kg and SD = 9.7 kg). The 2DE showed left heart lesions in nine patients (20.9%), right heart lesions in 23 (53.5%), atrial septal defects in five (11.6%) and complex CHD in six patients (14%). The 3DE MPR technique application and analysis was possible in all patients. The study demonstrated the fields where 3DE MPR was of additive value to conventional 2DE for the vena contracta area in valvular regurgitation severity and the planimetry for the valvular stenosis precise estimation, enface views of atrial septal defects with direct visualisation of shape and size of the defect, and segmental analysis of complex CHD using one window. The clinician and surgeon were then able to determine the mechanism and severity of the lesions and thus decide on appropriate treatment and management.
CONCLUSION: The study demonstrated the usefulness of 3DE-MPR as a complement to conventional 2DE. The technique is a significant technological breakthrough that allows instant visualization of morphological details and precise determination of cardiac valvular lesions, which were less clearly delineated by 2DE alone.

Entities:  

Keywords:  Congenital heart disease; Echocardiography; Multiplanar reformatting; Three-dimensional echocardiography; Two-dimensional echocardiography

Year:  2013        PMID: 24578597      PMCID: PMC3936236          DOI: 10.1016/j.jsha.2013.11.004

Source DB:  PubMed          Journal:  J Saudi Heart Assoc        ISSN: 1016-7315


  36 in total

1.  Three-dimensional echocardiography improves the understanding of the mechanisms and site of left atrioventricular valve regurgitation in atrioventricular septal defect.

Authors:  Ken Takahashi; Vitor Guerra; Kevin S Roman; Masaki Nii; Andrew Redington; Jeffery F Smallhorn
Journal:  J Am Soc Echocardiogr       Date:  2006-12       Impact factor: 5.251

2.  Quantification of tricuspid regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area.

Authors:  Dasan E Velayudhan; Todd M Brown; Navin C Nanda; Vinod Patel; Andrew P Miller; Farhat Mehmood; Sanjay Rajdev; Ligang Fang; Ebenezer E Frans; Srinivas Vengala; Pavan Madadi; Pridhvi Yelamanchili; Oben Baysan
Journal:  Echocardiography       Date:  2006-10       Impact factor: 1.724

3.  Real-time three-dimensional transthoracic echocardiography.

Authors:  Ravi R Kasliwal; Nagendra S Chouhan; Ashish Sinha; Pankaj Gupta; Sharad Tandon; Naresh Trehan
Journal:  Indian Heart J       Date:  2005 Mar-Apr

4.  Head-to-head comparison of two- and three-dimensional transthoracic and transesophageal echocardiography in the localization of mitral valve prolapse.

Authors:  Mauro Pepi; Gloria Tamborini; Anna Maltagliati; Claudia Agnese Galli; Erminio Sisillo; Luca Salvi; Moreno Naliato; Massimo Porqueddu; Alessandro Parolari; Marco Zanobini; Francesco Alamanni
Journal:  J Am Coll Cardiol       Date:  2006-11-28       Impact factor: 24.094

5.  When should Doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow states.

Authors:  J Segal; D J Lerner; D C Miller; R S Mitchell; E A Alderman; R L Popp
Journal:  J Am Coll Cardiol       Date:  1987-06       Impact factor: 24.094

6.  A system for ultrasonically imaging the human heart in three dimensions.

Authors:  D L Dekker; R L Piziali; E Dong
Journal:  Comput Biomed Res       Date:  1974-12

7.  Comparison of hemodynamic pressure half-time method and Gorlin formula with Doppler and echocardiographic determinations of mitral valve area in patients with combined mitral stenosis and regurgitation.

Authors:  C S Fredman; A C Pearson; A J Labovitz; M J Kern
Journal:  Am Heart J       Date:  1990-01       Impact factor: 4.749

8.  Real-time 3-dimensional echocardiographic imaging of congenital heart disease using matrix-array technology: freehand real-time scanning adds instant morphologic details not well delineated by conventional 2-dimensional imaging.

Authors:  Mohamed A Seliem; Anysia Fedec; Meryl S Cohen; Stanford Ewing; Paul E Farrell; Jack Rychik; Amy H Schultz; J William Gaynor; Thomas L Spray
Journal:  J Am Soc Echocardiogr       Date:  2006-02       Impact factor: 5.251

9.  Usefulness of transesophageal three-dimensional echocardiography in the identification of individual segment/scallop prolapse of the mitral valve.

Authors:  Sujood Ahmed; Navin C Nanda; Andrew P Miller; Rajasekhar Nekkanti; Abdalla M Yousif; Albert D Pacifico; James K Kirklin; David C McGiffin
Journal:  Echocardiography       Date:  2003-02       Impact factor: 1.724

10.  Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: an accurate and novel approach.

Authors:  José Zamorano; Pedro Cordeiro; Lissa Sugeng; Leopoldo Perez de Isla; Lynn Weinert; Carlos Macaya; Enrique Rodríguez; Roberto M Lang
Journal:  J Am Coll Cardiol       Date:  2004-06-02       Impact factor: 24.094

View more
  2 in total

1.  Quantification of aortic valve area: comparison of different methods of echocardiography with 3-D scan of the excised valve.

Authors:  Samira Shirazi; Fatemeh Golmohammadi; Anahita Tavoosi; Mehrdad Salehi; Farnoosh Larti; Akram Sardari; Babak Geraiely; Mehrzad Rahmanian; Kianoush Saberi; Roya Sattarzadeh Badkoubeh
Journal:  Int J Cardiovasc Imaging       Date:  2020-10-01       Impact factor: 2.357

2.  The role of trans-thoracic echocardiography in the assessment of aortic annular diameter.

Authors:  Khaled I Naguib; Mohamed A Attia; Mohamed S Bashandy; Muhammad Saad Reihan; Tarek Ahmed Dabash; Ahmed B Abd El-Salam; Hosam H Helal; Eshak I Bahbah
Journal:  Medicine (Baltimore)       Date:  2021-03-05       Impact factor: 1.817

  2 in total