Literature DB >> 11328731

ETDRS-fast: implementing psychophysical adaptive methods to standardized visual acuity measurement with ETDRS charts.

M Camparini1, P Cassinari, L Ferrigno, C Macaluso.   

Abstract

PURPOSE: To measure visual acuity (VA) on Early Treatment Diabetic Retinopathy Study (ETDRS) charts with a modified faster procedure (ETDRS-Fast), based on adaptive psychophysics methods and to assess the method's validity and reproducibility.
METHODS: Whereas the standard method for measuring VA with the ETDRS charts requires that the subject read all the letters beginning with the top row, in the ETDRS-Fast procedure, the subject is asked to read only one letter per row until a mistake is made. Then, following simple rules, the examiner finds a row from which the subject can begin reading all the letters downward, thus making the method identical with the standard method near threshold. VA determination was performed twice with both methods in 57 subjects in two separate sessions to assess validity and reproducibility.
RESULTS: In both sessions the correlation between the two procedures was high (intraclass correlation coefficient 0.95), confirming the validity of the ETDRS-Fast procedure. Reproducibility was good for both procedures, with intraclass correlation coefficients of 0.94 for the standard and 0.96 for the ETDRS-Fast method. The ETDRS-Fast procedure allowed a significantly shorter test duration (-30%; P < 0.0001).
CONCLUSIONS: Adaptive procedures allow accurate and fast determination of psychophysical thresholds by reducing the number of stimulus presentations when the subject is far from threshold. In the ETDRS-Fast method a few simple rules applied to optotype chart reading allow adaptation to each patient's level of VA. The ETDRS-Fast procedure significantly reduces test time and still yields results that are as accurate as those obtained with the standard method.

Entities:  

Mesh:

Year:  2001        PMID: 11328731

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  24 in total

1.  Reliability of a standardized reading chart system: variance component analysis, test-retest and inter-chart reliability.

Authors:  Eva Stifter; Franz König; Thomas Lang; Peter Bauer; Sibylla Richter-Müksch; Michaela Velikay-Parel; Wolfgang Radner
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-12-10       Impact factor: 3.117

2.  Reliability of acuities determined with the sweep visual evoked potential (sVEP).

Authors:  William H Ridder; Anna Tong; Theresa Floresca
Journal:  Doc Ophthalmol       Date:  2012-01-20       Impact factor: 2.379

3.  Repeatability of mesopic visual acuity measurements using high- and low-contrast ETDRS letter charts.

Authors:  Ana Barrio; Beatriz Antona; María C Puell
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-12-09       Impact factor: 3.117

4.  Performance of a computerised visual acuity measurement device in subjects with age-related macular degeneration: comparison with gold standard ETDRS chart measurements.

Authors:  Y Bokinni; N Shah; O Maguire; D A H Laidlaw
Journal:  Eye (Lond)       Date:  2015-06-05       Impact factor: 3.775

5.  Impact of low luminance conditions on quality of life for the visually impaired: development of the Low Luminance Questionnaire Japanese version.

Authors:  Kyoko Fujita; Yoshimi Suzukamo; Kenta Murotani; Akiko Jinno; Motohiro Kamei
Journal:  Jpn J Ophthalmol       Date:  2021-05-15       Impact factor: 2.447

6.  Assessing visual acuity across five disease types: ETDRS charts are faster with clinical outcome comparable to Landolt Cs.

Authors:  Simone Koenig; Felix Tonagel; Ulrich Schiefer; Michael Bach; Sven P Heinrich
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-28       Impact factor: 3.117

7.  Reduced visual acuity in children from 5 to 6 years old, with LEA chart.

Authors:  Amélia Fernandes Nunes; F Sena; R Calado; A R R Tuna; A P R Gonçalves; P L Monteiro
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-09-18       Impact factor: 3.117

8.  Repeatability of Monocular Acuity Testing in Adults with and without Down Syndrome.

Authors:  Ayeswarya Ravikumar; Julia S Benoit; Kelsie B Morrison; Jason D Marsack; Heather A Anderson
Journal:  Optom Vis Sci       Date:  2018-03       Impact factor: 1.973

9.  The effect of induced monocular blur on measures of stereoacuity.

Authors:  Naomi V Odell; Sarah R Hatt; David A Leske; Wendy E Adams; Jonathan M Holmes
Journal:  J AAPOS       Date:  2008-12-13       Impact factor: 1.220

10.  The effect of Bangerter filters on optotype acuity, Vernier acuity, and contrast sensitivity.

Authors:  Naomi V Odell; David A Leske; Sarah R Hatt; Wendy E Adams; Jonathan M Holmes
Journal:  J AAPOS       Date:  2008-08-15       Impact factor: 1.220

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.