Literature DB >> 11324950

The MLC tongue-and-groove effect on IMRT dose distributions.

J Deng1, T Pawlicki, Y Chen, J Li, S B Jiang, C M Ma.   

Abstract

We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groove effect could be up to 10% of the maximum dose in the dose distributions. For an IMRT treatment with multiple gantry angles (> or = 5), the difference between the dose distributions with and without the tongue-and-groove effect was hardly visible, less than 1.6% for the two typical clinical cases studied. After considering the patient setup errors, the dose distributions were smoothed with reduced and insignificant differences between plans with and without the tongue-and-groove effect. Therefore, for a multiple-field IMRT plan (> or = 5), the tongue-and-groove effect on the IMRT dose distributions will be generally clinically insignificant due to the smearing effect of individual fields. The tongue-and-groove effect on an IMRT plan with small number of fields (< 5) will vary depending on the number of fields in a plan (coplanar or non-coplanar), the MLC leaf sequences and the patient setup uncertainty, and may be significant (> 5% of maximum dose) in some cases, especially when the patient setup uncertainty is small (< or = 2 mm).

Entities:  

Mesh:

Year:  2001        PMID: 11324950     DOI: 10.1088/0031-9155/46/4/310

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

1.  Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.

Authors:  I B Mihaylov; F A Lerma; Y Wu; J V Siebers
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

2.  Anatomy-corresponding method of IMRT verification.

Authors:  Janusz Winiecki; Zbigniew Zurawski; Barbara Drzewiecka; Krzysztof Slosarek
Journal:  Rep Pract Oncol Radiother       Date:  2010-12-04

3.  Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4.

Authors:  Hiroyuki Okamoto; Yukio Fujita; Kyoko Sakama; Hidetoshi Saitoh; Tatsuaki Kanai; Jun Itami; Toshiyuki Kohno
Journal:  Radiol Phys Technol       Date:  2014-02-08

4.  Investigating the dosimetric effects of grid size on dose calculation accuracy using volumetric modulated arc therapy in spine stereotactic radiosurgery.

Authors:  Chin Snyder Karen; Manju Liu; Bo Zhao; Yimei Huang; Wen Ning; Indrin J Chetty; M Salim Siddiqui
Journal:  J Radiosurg SBRT       Date:  2017

5.  Statistical analysis of IMRT dosimetry quality assurance measurements for local delivery guideline.

Authors:  Jin Beom Chung; Jae Sung Kim; Sung Whan Ha; Sung-Joon Ye
Journal:  Radiat Oncol       Date:  2011-03-28       Impact factor: 3.481

Review 6.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

7.  The dosimetric impact of different photon beam energy on RapidArc radiotherapy planning for cervix carcinoma.

Authors:  Lalit Kumar; Girigesh Yadav; Kothanda Raman; Manindra Bhushan; Manoj Pal
Journal:  J Med Phys       Date:  2015 Oct-Dec

8.  Evaluation of triple channel correction acquisition method for radiochromic film dosimetry.

Authors:  Naoki Hayashi; Yoichi Watanabe; Ryan Malmin; Hideki Kato
Journal:  J Radiat Res       Date:  2012-08-21       Impact factor: 2.724

9.  Advanced nasopharyngeal carcinoma radiotherapy with volumetric modulated arcs and the potential role of flattening filter-free beams.

Authors:  Mingzan Zhuang; Tuodan Zhang; Zhijian Chen; Zhixiong Lin; Derui Li; Xun Peng; Qingchun Qiu; Renhua Wu
Journal:  Radiat Oncol       Date:  2013-05-14       Impact factor: 3.481

10.  Capability of leaf interdigitation with different inverse planning strategies in Monaco: an investigation of representative tumour sites.

Authors:  Jinghao Duan; Xiangjuan Meng; Tonghai Liu; Yong Yin
Journal:  Radiat Oncol       Date:  2016-06-17       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.