Morphologic changes in the lumbar intervertebral foramen due to flexion-extension, lateral bending, and axial rotation: an in vitro anatomic and biomechanical study.

A Fujiwara1, H S An, T H Lim, V M Haughton.   

Abstract

STUDY
DESIGN: A biomechanical and anatomic study with human cadaveric lumbar spine.
OBJECTIVES: The purpose of this study is to examine the morphologic changes in the intervertebral foramen during flexion, extension, lateral bending, and axial rotation of the lumbar spine and to correlate these changes with the flexibility of the spinal motion segments. SUMMARY OF BACKGROUND DATA: Previous studies showed morphologic changes in the intervertebral foramen during flexion and extension; however, those changes during lateral bending and axial rotation were not well known.
METHODS: There were 81 motion segments obtained from 39 human cadaveric lumbar spines (mean age 69 years). The motion segments were imaged with CT scanner with 1-mm thick consecutive sections. For biomechanical testing each motion segment was applied with incremental pure moments of flexion, extension, lateral bending, and axial rotation. Rotational movements of the motion segment were measured using VICON cameras. After application of the last load, the specimens were frozen under load, and then CT was performed with the same technique described above. Six parameters of the intervertebral foramen were measured, including foraminal width (maximum and minimum), foraminal height, disc bulging, thickness of ligamentum flavum, and cross-sectional area of the foramen.
RESULTS: Flexion increased the foraminal width (maximum and minimum), height, and area significantly while significantly decreasing the disc bulging and thickness of ligamentum flavum (P < 0.05). However, extension decreased the foraminal width (maximum and minimum), height, and area significantly. Lateral bending significantly decreased the foraminal width (maximum and minimum), height, and area at the bending side, whereas lateral bending significantly increased the foraminal width (minimum), height, and area at the opposite side of bending. Likewise, axial rotation decreased the foraminal width (minimum) and area at the rotation side significantly while significantly increasing the foraminal height and foraminal area at the opposite side. The percent change in the foraminal area was found significantly correlated with the amount of segmental spinal motion except for the extension motion.
CONCLUSIONS: This study showed that the intervertebral foramen of the lumbar spine changed significantly not only on flexion-extension but also on lateral bending and axial rotation. The percent change in cross-sectional foraminal area was correlated with the amount of segmental motion except for extension motions. Further studies are needed to assess the morphologic changes in the intervertebral foramen in vivo and to correlate clinically.

Entities:  

Mesh:

Year:  2001        PMID: 11317109     DOI: 10.1097/00007632-200104150-00010

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  45 in total

1.  The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis.

Authors:  Zongmiao Wan; Shaobai Wang; Michal Kozanek; Qun Xia; Frederick L Mansfield; Guohua Lü; Kirkham B Wood; Guoan Li
Journal:  Eur Spine J       Date:  2011-09-21       Impact factor: 3.134

2.  Clinical perspectives on secular trends of intervertebral foramen diameters in an industrialized European society.

Authors:  Frank J Rühli; Maciej Henneberg
Journal:  Eur Spine J       Date:  2004-04-01       Impact factor: 3.134

3.  Stabilising effect of dynamic interspinous spacers in degenerative low-grade lumbar instability.

Authors:  Johannes Holinka; Petra Krepler; Michael Matzner; Josef G Grohs
Journal:  Int Orthop       Date:  2010-04-25       Impact factor: 3.075

4.  Upright, weight-bearing, dynamic-kinetic MRI of the spine: initial results.

Authors:  J Randy Jinkins; Jay S Dworkin; Raymond V Damadian
Journal:  Eur Radiol       Date:  2005-05-20       Impact factor: 5.315

5.  A validated finite element analysis of nerve root stress in degenerative lumbar scoliosis.

Authors:  Ho-Joong Kim; Heoung-Jae Chun; Kyoung-Tak Kang; Hwan-Mo Lee; Hak-Sun Kim; Eun-Su Moon; Jin-Oh Park; Bo-Hyun Hwang; Ju-Hyun Son; Seong-Hwan Moon
Journal:  Med Biol Eng Comput       Date:  2009-03-19       Impact factor: 2.602

6.  Interspinous implants (X Stop, Wallis, Diam) for the treatment of LSS: is there a correlation between radiological parameters and clinical outcome?

Authors:  Rolf Sobottke; Klaus Schlüter-Brust; Thomas Kaulhausen; Marc Röllinghoff; Britta Joswig; Hartmut Stützer; Peer Eysel; Patrick Simons; Johannes Kuchta
Journal:  Eur Spine J       Date:  2009-06-27       Impact factor: 3.134

7.  Effects of Axial Torsion on Disc Height Distribution: An In Vivo Study.

Authors:  Alejandro A Espinoza Orías; Nicole M Mammoser; John J Triano; Howard S An; Gunnar B J Andersson; Nozomu Inoue
Journal:  J Manipulative Physiol Ther       Date:  2016-04-06       Impact factor: 1.437

8.  Role of coflex as an adjunct to decompression for symptomatic lumbar spinal stenosis.

Authors:  Naresh Kumar; Siddarth M Shah; Yau Hong Ng; Vinodh Kumar Pannierselvam; Sudeep Dasde; Liang Shen
Journal:  Asian Spine J       Date:  2014-04-08

9.  A prospective randomized multi-center study for the treatment of lumbar spinal stenosis with the X STOP interspinous implant: 1-year results.

Authors:  J F Zucherman; K Y Hsu; C A Hartjen; T F Mehalic; D A Implicito; M J Martin; D R Johnson; G A Skidmore; P P Vessa; J W Dwyer; S Puccio; J C Cauthen; R M Ozuna
Journal:  Eur Spine J       Date:  2003-12-19       Impact factor: 3.134

10.  Spinal decompensation in degenerative lumbar scoliosis.

Authors:  A A Benjamin de Vries; Margriet G Mullender; Winand J Pluymakers; René M Castelein; Barend J van Royen
Journal:  Eur Spine J       Date:  2010-03-19       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.