Literature DB >> 11311027

Reliability of power output measurements during repeated treadmill sprinting in rugby players.

R J Tong1, W Bell, G Ball, E M Winter.   

Abstract

The non-motorized treadmill system initially reported by Lakomy in 1984 has been used extensively to assess sprinting performance. However, there has been limited research into the reliability of power output measurement using such systems. The aim of this study was to design a system and protocol capable of measuring treadmill sprinting performance in rugby players and to assess the reliability of this system for measuring power output. Twenty-seven rugby players, all of whom were familiar with treadmill sprinting, performed three maximal 6 s sprints with 2 min recovery between sprints, on two occasions 1 week apart. Both tests were performed on a non-motorized Woodway tramp treadmill, interfaced to a data acquisition system. There were no significant differences (P > 0.05) between power output for repeated trials on the same day (between trials) or for repeated trials on different days (between days). Limits of agreement for maximum average power (the average of 100 readings per second) were 4+/-98 and 30+/-157 W for between trials and between days, respectively. When reported as ratio limits of agreement, these were 1.07 (*/divided 1.12) and 1.03 (*/divided 1.16), respectively. The limits of agreement for maximum instantaneous power (the highest of 100 readings per second) were 51+/-464 and 105+/-588 W for between trials and between days, respectively. When reported as ratio limits of agreement, these were 1.02 (*/divided 1.20) and 1.04 (*/divided 1.21) for between trials and between days, respectively. The coefficients of variation for all measures of power output were less than 9.3%. Hence, the treadmill system and protocol developed in this study provide a reliable measure of power output for rugby players.

Mesh:

Year:  2001        PMID: 11311027     DOI: 10.1080/026404101750158394

Source DB:  PubMed          Journal:  J Sports Sci        ISSN: 0264-0414            Impact factor:   3.337


  8 in total

Review 1.  Applied physiology and game analysis of rugby union.

Authors:  Grant Duthie; David Pyne; Sue Hooper
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

2.  Familiarisation and reliability of sprint test indices during laboratory and field assessment.

Authors:  James G Hopker; Damian A Coleman; Jonathan D Wiles; Andrew Galbraith
Journal:  J Sports Sci Med       Date:  2009-12-01       Impact factor: 2.988

Review 3.  Advances in Sprint Acceleration Profiling for Field-Based Team-Sport Athletes: Utility, Reliability, Validity and Limitations.

Authors:  Kim D Simperingham; John B Cronin; Angus Ross
Journal:  Sports Med       Date:  2016-11       Impact factor: 11.136

4.  Reliability of the Woodway Curve(TM) Non-Motorized Treadmill for Assessing Anaerobic Performance.

Authors:  Adam M Gonzalez; Adam J Wells; Jay R Hoffman; Jeffrey R Stout; Maren S Fragala; Gerald T Mangine; William P McCormack; Jeremy R Townsend; Adam R Jajtner; Nadia S Emerson; Edward H Robinson Iv
Journal:  J Sports Sci Med       Date:  2013-03-01       Impact factor: 2.988

5.  Effects of Motorized vs Non-Motorized Treadmill Training on Hamstring/Quadriceps Strength Ratios.

Authors:  Kelly A Franks; Lee E Brown; Jared W Coburn; Robert D Kersey; Martim Bottaro
Journal:  J Sports Sci Med       Date:  2012-03-01       Impact factor: 2.988

6.  Fatigue Indices and Perceived Exertion Highlight Ergometer Specificity for Repeated Sprint Ability Testing.

Authors:  Hugo A Kerhervé; David G Stewart; Chris McLellan; Dale Lovell
Journal:  Front Sports Act Living       Date:  2020-05-15

Review 7.  Fitness testing of tennis players: how valuable is it?

Authors:  Jaime Fernandez-Fernandez; Alexander Ulbricht; Alexander Ferrauti
Journal:  Br J Sports Med       Date:  2014-04       Impact factor: 13.800

8.  Appropriate loads for peak-power during resisted sprinting on a non-motorized treadmill.

Authors:  Matthew J Andre; Andrew C Fry; Michael T Lane
Journal:  J Hum Kinet       Date:  2013-10-08       Impact factor: 2.193

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.