Literature DB >> 11271433

Comparison of different 3D navigation systems by a clinical "user".

M Cartellieri1, J Kremser, F Vorbeck.   

Abstract

Three-dimensional navigation systems are routinely used in endoscopic skull base surgery, neurosurgery, maxillo-facial and endoscopic sinus surgery. Their precision can, however, change in the course of one experiment. We have compared five different 3D navigation systems and discuss here possible reasons for the limits of system precision. A plexiglass cube on which test points were marked served as a test-model. Two well-trained system users measured the distances between the test points in each of the five systems. The results were compared with reference data provided by the NUMEREX device at the Technical University of Vienna. The accuracy data shown by all these 3D navigation systems ranged from 0.0 mm to 6.67 mm. The accuracy data of a system calculated in advance did not always correspond with the system precision on the screen. The system precision in the center of the cube was higher than on its surface, which made us conclude that the angle between the tracker system and the pointing device touching the test point may be critical for system precision. Applying an automatic registration step did not result in greater system precision. Slice thickness and the angle of the pointing device seem to be responsible for system precision.

Mesh:

Year:  2001        PMID: 11271433     DOI: 10.1007/s004050000302

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  4 in total

1.  Deformable three-dimensional model architecture for interactive augmented reality in minimally invasive surgery.

Authors:  Anant S Vemuri; Jungle Chi-Hsiang Wu; Kai-Che Liu; Hurng-Sheng Wu
Journal:  Surg Endosc       Date:  2012-06-27       Impact factor: 4.584

2.  Comparative study of application accuracy of two frameless neuronavigation systems: experimental error assessment quantifying registration methods and clinically influencing factors.

Authors:  Dimitrios Paraskevopoulos; Andreas Unterberg; Roland Metzner; Jens Dreyhaupt; Georg Eggers; Christian Rainer Wirtz
Journal:  Neurosurg Rev       Date:  2011-01-19       Impact factor: 3.042

3.  Laparoscopic navigation pointer for three-dimensional image-guided surgery.

Authors:  R Mårvik; T Langø; G A Tangen; J O Andersen; J H Kaspersen; B Ystgaard; E Sjølie; R Fougner; H E Fjøsne; T A Nagelhus Hernes
Journal:  Surg Endosc       Date:  2004-06-23       Impact factor: 4.584

4.  The Application of Three-Dimensional Technologies in the Improvement of Orthopedic Surgery Training and Medical Education Quality: A Comparative Bibliometrics Analysis.

Authors:  Jian Shi; María José Cavagnaro; Shaokang Xu; Mingyi Zhao
Journal:  Front Bioeng Biotechnol       Date:  2022-03-22
  4 in total