S R Armstrong1, J C Keller, D B Boyer. 1. Department of Operative Dentistry, University of Iowa, Iowa City, IA, USA. steven-armstrong@uiowa.edu
Abstract
OBJECTIVE: To test the elastic wall concept utilizing adhesive resins of varying stiffness in a low- and high-C-factor cavity design after short- and long-term water storage. METHODS: A flat and box-shaped cavity was restored on occlusal dentin with a resin composite using a filled and unfilled adhesive resin from which microtensile specimens with a 0.5mm(2) cross-sectional area were formed. After storage for 30- and 150-days the microtensile bond strength (muTBS) was determined in a Zwick materials testing machine and the subsequent debond pathway was examined under scanning electron microscopy. Fisher's exact test was used to determine differences in joint and substrate failure modes and a Weibull regression model with gamma frailties was used to test for differences between failure distributions. Tests for three-way and two-way interactions were also completed for storage time, C-factor and adhesive. All tests were at 95% confidence levels. RESULTS: The characteristic strength (TBS degrees ) for the Optibond FL adhesive applied on a flat cavity was 47.57 and 20.90MPa and a box-shaped cavity was 49.26 and 17.49MPa for short- and long-term storage, respectively, while the corresponding TBS degrees for the unfilled Optibond adhesive on the flat cavity design was 36.93 and 32.68MPa and in a box-shaped cavity was 32.84 and 15.46MPa. Combining all groups according to storage time revealed a three-fold increase in the debond pathway including the bottom of the hybrid layer. SIGNIFICANCE: Evidence suggests that the durability of the bonded joint is threatened by hydrolysis and the most susceptible region is the bottom half of the hybrid layer and in low C-factor cavity designs a more flexible adhesive resin liner was more durable.
OBJECTIVE: To test the elastic wall concept utilizing adhesive resins of varying stiffness in a low- and high-C-factor cavity design after short- and long-term water storage. METHODS: A flat and box-shaped cavity was restored on occlusal dentin with a resin composite using a filled and unfilled adhesive resin from which microtensile specimens with a 0.5mm(2) cross-sectional area were formed. After storage for 30- and 150-days the microtensile bond strength (muTBS) was determined in a Zwick materials testing machine and the subsequent debond pathway was examined under scanning electron microscopy. Fisher's exact test was used to determine differences in joint and substrate failure modes and a Weibull regression model with gamma frailties was used to test for differences between failure distributions. Tests for three-way and two-way interactions were also completed for storage time, C-factor and adhesive. All tests were at 95% confidence levels. RESULTS: The characteristic strength (TBS degrees ) for the Optibond FL adhesive applied on a flat cavity was 47.57 and 20.90MPa and a box-shaped cavity was 49.26 and 17.49MPa for short- and long-term storage, respectively, while the corresponding TBS degrees for the unfilled Optibond adhesive on the flat cavity design was 36.93 and 32.68MPa and in a box-shaped cavity was 32.84 and 15.46MPa. Combining all groups according to storage time revealed a three-fold increase in the debond pathway including the bottom of the hybrid layer. SIGNIFICANCE: Evidence suggests that the durability of the bonded joint is threatened by hydrolysis and the most susceptible region is the bottom half of the hybrid layer and in low C-factor cavity designs a more flexible adhesive resin liner was more durable.
Authors: Manuel Toledano; Raquel Osorio; Estrella Osorio; Fátima S Aguilera; Monica Yamauti; David H Pashley; Franklin Tay Journal: J Mater Sci Mater Med Date: 2007-06-14 Impact factor: 3.896
Authors: Annalisa Mazzoni; David H Pashley; Alessandra Ruggeri; Francesca Vita; Mirella Falconi; Roberto Di Lenarda; Lorenzo Breschi Journal: J Biomed Mater Res B Appl Biomater Date: 2008-07 Impact factor: 3.368