Effects of x-ray spectra on the DQE of a computed radiography system.

K A Fetterly1, N J Hangiandreou.   

Abstract

The effect of incident x-ray beam quality on the measured detective quantum efficiency (DQE) of a computed radiography system was investigated. The incident x-ray beams used had peak tube potentials of 70, 95, and 120 kVp, were filtered with various thicknesses of a "patient equivalent phantom" (PEP), aluminum, and copper, and provided a consistent exposure to the storage phosphor. For each peak tube potential and filter combination, the one-dimensional modulation transfer function and noise power spectrum were measured and the square of the incident signal-to-noise ratio was estimated. The spatial frequency dependent DQE was calculated from these data. The DQE was integrated to provide an overall estimate of the efficiency and frequency response of the computed radiography system for the various x-ray beams. There was found to be a wide range of integral DQE (IDQE) values for the peak tube potential and filter combinations used. For example, the IDQE ranged from 3.0 to 0.9 mm(-2) using the peak tube potential and filter combinations 70 kVp with 5.1 cm PEP and 120 kVp with 30.3 cm PEP, respectively. Finally, peak tube potential and filter combinations 70 kVp with 10.2 cm PEP and 120 kVp with 20.2 cm PEP were chosen as standard x-ray beams that will be used at our facility to measure the DQE of digital radiographic imaging systems for evaluation and acceptance testing.

Entities:  

Mesh:

Year:  2001        PMID: 11243349     DOI: 10.1118/1.1339883

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Accurate MTF measurement in digital radiography using noise response.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Kenneth R Hoffmann; Stephen Rudin
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

2.  Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

Authors:  C S Moore; T J Wood; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2013-04-08       Impact factor: 3.039

3.  Modeling the performance characteristics of computed radiography (CR) systems.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  IEEE Trans Med Imaging       Date:  2010-03       Impact factor: 10.048

4.  Performance evaluation of three computed radiography systems using methods recommended in American Association of Physicists in Medicine Report 93.

Authors:  Wilbroad Muhogora; Renato Padovani; Faustino Bonutti; Peter Msaki; R Kazema
Journal:  J Med Phys       Date:  2011-07

5.  Effect of beam quality and readout direction in the edge profile on the modulation transfer function of photostimulable phosphor systems via the edge method.

Authors:  Shinya Takarabe; Taku Kuramoto; Yusuke Shibayama; Hiroki Tsuru; Masato Tatsumi; Toyoyuki Kato; Kazutoshi Okamura; Kazunori Yoshiura
Journal:  J Med Imaging (Bellingham)       Date:  2021-07-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.