Literature DB >> 11241707

Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRI.

M J van Osch1, E J Vonken , C J Bakker, M A Viergever.   

Abstract

To quantify cerebral perfusion with dynamic susceptibility contrast MRI (DSC-MRI), one needs to measure the arterial input function (AIF). Conventionally, one derives the contrast concentration from the DSC sequence by monitoring changes in either the amplitude or the phase signal on the assumption that the signal arises completely from blood. In practice, partial volume artifacts are inevitable because a compromise has to be reached between the temporal and spatial resolution of the DSC acquisition. As the concentration of the contrast agent increases, the vector of the complex blood signal follows a spiral-like trajectory. In the case of a partial-volume voxel, the spiral is located around the static contribution of the surrounding tissue. If the static contribution of the background tissue is disregarded, estimations of the contrast concentration will be incorrect. By optimizing the correspondence between phase information and amplitude information one can estimate the origin of the spiral, and thereupon correct for partial volume artifacts. This correction is shown to be accurate at low spatial resolutions for phantom data and to improve the AIF determination in a clinical example. Magn Reson Med 45:477-485, 2001. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2001        PMID: 11241707     DOI: 10.1002/1522-2594(200103)45:3<477::aid-mrm1063>3.0.co;2-4

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  SCALE-PWI: A pulse sequence for absolute quantitative cerebral perfusion imaging.

Authors:  Jessy Mouannes Srour; Wanyong Shin; Saurabh Shah; Anindya Sen; Timothy J Carroll
Journal:  J Cereb Blood Flow Metab       Date:  2010-12-15       Impact factor: 6.200

2.  Identifying systematic errors in quantitative dynamic-susceptibility contrast perfusion imaging by high-resolution multi-echo parallel EPI.

Authors:  Thies H Jochimsen; Rexford D Newbould; Stefan T Skare; David B Clayton; Gregory W Albers; Michael E Moseley; Roland Bammer
Journal:  NMR Biomed       Date:  2007-06       Impact factor: 4.044

Review 3.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

4.  A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations.

Authors:  Matthias C Schabel; Jacob U Fluckiger; Edward V R DiBella
Journal:  Phys Med Biol       Date:  2010-08-03       Impact factor: 3.609

5.  Impact of the arterial input function on microvascularization parameter measurements using dynamic contrast-enhanced ultrasonography.

Authors:  Marianne Gauthier; Stéphanie Pitre-Champagnat; Farid Tabarout; Ingrid Leguerney; Mélanie Polrot; Nathalie Lassau
Journal:  World J Radiol       Date:  2012-07-28

6.  Perfusion-weighted MR imaging studies in brain hypervascular diseases: comparison of arterial input function extractions for perfusion measurement.

Authors:  D Ducreux; I Buvat; J F Meder; D Mikulis; A Crawley; D Fredy; K TerBrugge; P Lasjaunias; J Bittoun
Journal:  AJNR Am J Neuroradiol       Date:  2006-05       Impact factor: 3.825

Review 7.  Vessel caliber--a potential MRI biomarker of tumour response in clinical trials.

Authors:  Kyrre E Emblem; Christian T Farrar; Elizabeth R Gerstner; Tracy T Batchelor; Ronald J H Borra; Bruce R Rosen; A Gregory Sorensen; Rakesh K Jain
Journal:  Nat Rev Clin Oncol       Date:  2014-08-12       Impact factor: 66.675

8.  Combined T2* and T1 measurements for improved perfusion and permeability studies in high field using dynamic contrast enhancement.

Authors:  Cedric de Bazelaire; Neil M Rofsky; Guillaume Duhamel; Jingbo Zhang; M Dror Michaelson; Daniel George; David C Alsop
Journal:  Eur Radiol       Date:  2006-04-01       Impact factor: 5.315

9.  Heterogeneity of cortical lesions in multiple sclerosis: an MRI perfusion study.

Authors:  Denis Peruzzo; Marco Castellaro; Massimiliano Calabrese; Elisa Veronese; Francesca Rinaldi; Valentina Bernardi; Alice Favaretto; Paolo Gallo; Alessandra Bertoldo
Journal:  J Cereb Blood Flow Metab       Date:  2012-12-19       Impact factor: 6.200

10.  Contrast agent dose effects in cerebral dynamic susceptibility contrast magnetic resonance perfusion imaging.

Authors:  Jeffry R Alger; Timothy J Schaewe; Tom C Lai; Andrew J Frew; Paul M Vespa; Maria Etchepare; David S Liebeskind; Jeffrey L Saver; S Chelsea Kidwell
Journal:  J Magn Reson Imaging       Date:  2009-01       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.