V J Canzanello1, P L Jensen, G L Schwartz. 1. Division of Hypertension, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA. canzanello.vincent@mayo.edu
Abstract
BACKGROUND: The aneroid sphygmomanometer is commonly used for the indirect measurement of blood pressure despite significant concerns about its accuracy. Although the mercury sphygmomanometer is highly accurate, there are concerns about the environmental toxicity of mercury. In response to various external pressures to become essentially mercury free, the Mayo Clinic, Rochester, Minn, has replaced many mercury sphygmomanometers with aneroid devices. Since 1993, a maintenance protocol has been in place to ensure proper function and accuracy of these devices. METHODS: We assessed the accuracy of 283 aneroid devices using as the reference standard a digital pressure and vacuum meter that was calibrated using a mercury sphygmomanometer. RESULTS: The mean +/- SD values from the aneroid device in millimeters of mercury at each reference point (at 20-mm Hg intervals from 60 to 240 mm Hg defined by the reference device) were 59.9 +/- 1.9 at 60; 79.9 +/- 1.9 at 80; 100.0 +/- 1.8 at 100; 120.3 +/- 1.8 at 120; 140.7 +/- 1.4 at 140; 160.7 +/- 1.7 at 160; 180.9 +/- 1.3 at 180; 200.7 +/- 5.0 at 200; 221.0 +/- 1.3 at 220; and 240.8 +/- 1.6 at 240 (r = 0.99; P<.001). The values from the aneroid device underestimated those of the reference device by a mean of 0.5 mm Hg (95% confidence interval, 0.3-0.7). Virtually 100% of the values from the aneroid device were within the 4-mm Hg range recommended by the Association for the Advancement of Medical Instrumentation. CONCLUSION: Aneroid sphygmomanometers provide accurate pressure measurements when a proper maintenance protocol is followed.
BACKGROUND: The aneroid sphygmomanometer is commonly used for the indirect measurement of blood pressure despite significant concerns about its accuracy. Although the mercury sphygmomanometer is highly accurate, there are concerns about the environmental toxicity of mercury. In response to various external pressures to become essentially mercury free, the Mayo Clinic, Rochester, Minn, has replaced many mercury sphygmomanometers with aneroid devices. Since 1993, a maintenance protocol has been in place to ensure proper function and accuracy of these devices. METHODS: We assessed the accuracy of 283 aneroid devices using as the reference standard a digital pressure and vacuum meter that was calibrated using a mercury sphygmomanometer. RESULTS: The mean +/- SD values from the aneroid device in millimeters of mercury at each reference point (at 20-mm Hg intervals from 60 to 240 mm Hg defined by the reference device) were 59.9 +/- 1.9 at 60; 79.9 +/- 1.9 at 80; 100.0 +/- 1.8 at 100; 120.3 +/- 1.8 at 120; 140.7 +/- 1.4 at 140; 160.7 +/- 1.7 at 160; 180.9 +/- 1.3 at 180; 200.7 +/- 5.0 at 200; 221.0 +/- 1.3 at 220; and 240.8 +/- 1.6 at 240 (r = 0.99; P<.001). The values from the aneroid device underestimated those of the reference device by a mean of 0.5 mm Hg (95% confidence interval, 0.3-0.7). Virtually 100% of the values from the aneroid device were within the 4-mm Hg range recommended by the Association for the Advancement of Medical Instrumentation. CONCLUSION: Aneroid sphygmomanometers provide accurate pressure measurements when a proper maintenance protocol is followed.
Authors: Jordana B Cohen; Raj S Padwal; Michael Gutkin; Beverly B Green; Michael J Bloch; F Wilford Germino; Domenic A Sica; Anthony J Viera; Benjamin M Bluml; William B White; Sandra J Taler; Steven Yarows; Daichi Shimbo; Raymond R Townsend Journal: Hypertension Date: 2019-02 Impact factor: 10.190
Authors: Yong Ma; Marinella Temprosa; Sarah Fowler; Ronald J Prineas; Maria G Montez; Janet Brown-Friday; Mary L Carrion-Petersen; Tracy Whittington Journal: Am J Hypertens Date: 2008-12-04 Impact factor: 2.689
Authors: Wenjie Yang; Dongfeng Gu; Jing Chen; Cashell E Jaquish; D C Rao; Xigui Wu; James E Hixson; Xiufang Duan; Tanika N Kelly; L Lee Hamm; Paul K Whelton; Jiang He Journal: Am J Med Sci Date: 2008-11 Impact factor: 2.378