Literature DB >> 11229732

The accuracy and reliability of a novel handheld dynamic indentation probe for analysing articular cartilage.

R C Appleyard1, M V Swain, S Khanna, G A Murrell.   

Abstract

This study investigates the accuracy and reliability of a novel handheld indentation system designed to ascertain the dynamic biomechanical properties of articular cartilage. A series of standard elastomers were assessed with both the handheld indentation system and a bench-top dynamic indentation system to assess the accuracy of the instrument. Interoperator and intraoperator experiments were undertaken to investigate the reliability of the system when used by an individual operator and by five different operators. Intraclass coefficients (Rho) were derived using a random effects model. The system was then used to ascertain the topographical variation in the shear moduli and phase lag of articular cartilage across normal ovine tibial plateaux. The system was shown to be highly accurate (R2 = 0.97), and had excellent reliability when measuring the dynamic shear modulus of articular cartilage (interoperator Rho = 0.75, intraoperator Rho = 0.79). Measurement of static shear modulus was less reliable (interoperator Rho = 0.15, intraoperator Rho = 0.52), but may be improved by monitoring the load applied to the instrument by the operator. The instrument was used to differentiate between different regions of cartilage and generated a topographical map of an ovine tibial plateau. The cartilage located beneath the menisci was 200-500% stiffer than the cartilage that was not covered by the menisci, while the phase lag was almost constant (10+/-2 SD) over the entire tibial plateau. The system was shown to be an accurate and reliable tool for rapidly assessing the dynamic biomechanical properties of articular cartilage, while being small enough to be used arthroscopically.

Entities:  

Mesh:

Year:  2001        PMID: 11229732     DOI: 10.1088/0031-9155/46/2/319

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Physical indicators of cartilage health: the relevance of compliance, thickness, swelling and fibrillar texture.

Authors:  Neil D Broom; René Flachsmann
Journal:  J Anat       Date:  2003-06       Impact factor: 2.610

2.  A dynamic microindentation device with electrical contact detection.

Authors:  Matthew A Reilly; Gavin Perry; Nathan Ravi
Journal:  Rev Sci Instrum       Date:  2009-01       Impact factor: 1.523

3.  Micro- and nanomechanical analysis of articular cartilage by indentation-type atomic force microscopy: validation with a gel-microfiber composite.

Authors:  Marko Loparic; Dieter Wirz; A U Daniels; Roberto Raiteri; Mark R Vanlandingham; Geraldine Guex; Ivan Martin; Ueli Aebi; Martin Stolz
Journal:  Biophys J       Date:  2010-06-02       Impact factor: 4.033

4.  Correlation of dynamic impact testing, histopathology and visual macroscopic assessment in human osteoarthritic cartilage.

Authors:  Petr Kos; Ferdinand Varga; Milan Handl; Jakub Kautzner; Václav Chudáček; Milan Držík; Ctibor Povýšil; Tomáš Trč; Evžen Amler; Martin Hanus
Journal:  Int Orthop       Date:  2011-01-18       Impact factor: 3.075

5.  Quantitative MRI of Human Cartilage In Vivo: Relationships with Arthroscopic Indentation Stiffness and Defect Severity.

Authors:  Tuomas Svärd; Martti Lakovaara; Harri Pakarinen; Marianne Haapea; Ilkka Kiviranta; Eveliina Lammentausta; Jukka Jurvelin; Osmo Tervonen; Risto Ojala; Miika Nieminen
Journal:  Cartilage       Date:  2016-12-28       Impact factor: 4.634

Review 6.  Meniscal and chondral loss in the anterior cruciate ligament injured knee.

Authors:  Hugh P Jones; Richard C Appleyard; Sanjeev Mahajan; George A C Murrell
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

7.  Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy.

Authors:  Martin Stolz; Roberto Raiteri; A U Daniels; Mark R VanLandingham; Werner Baschong; Ueli Aebi
Journal:  Biophys J       Date:  2004-05       Impact factor: 4.033

8.  A finite element exploration of cartilage stress near an articular incongruity during unstable motion.

Authors:  Curtis M Goreham-Voss; Todd O McKinley; Thomas D Brown
Journal:  J Biomech       Date:  2007-06-29       Impact factor: 2.712

Review 9.  Atomic Force Microscopy on Biological Materials Related to Pathological Conditions.

Authors:  Andreas Stylianou; Stylianos-Vasileios Kontomaris; Colin Grant; Eleni Alexandratou
Journal:  Scanning       Date:  2019-05-12       Impact factor: 1.932

10.  Early Detection of Cartilage Degeneration: A Comparison of Histology, Fiber Bragg Grating-Based Micro-Indentation, and Atomic Force Microscopy-Based Nano-Indentation.

Authors:  Bastian Hartmann; Gabriele Marchi; Paolo Alberton; Zsuzsanna Farkas; Attila Aszodi; Johannes Roths; Hauke Clausen-Schaumann
Journal:  Int J Mol Sci       Date:  2020-10-06       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.