Literature DB >> 11222213

Learning curve for stereotactic breast biopsy: how many cases are enough?

L Liberman1, C L Benton, D D Dershaw, A F Abramson, L R LaTrenta, E A Morris.   

Abstract

OBJECTIVE: The objective of this study was to evaluate the learning curve for stereotactic breast biopsy.
MATERIALS AND METHODS: Retrospective review was performed of 923 consecutive lesions that underwent stereotactic breast biopsy performed by one of six radiologists. Four hundred fourteen lesions had 14-gauge automated core biopsy, and 509 subsequent lesions had vacuum-assisted biopsy (14-gauge in 163 and 11-gauge in 346). Medical records were reviewed to determine the technical success rate and false-negative rate as a function of operator experience.
RESULTS: For 14-gauge automated core biopsy, a significantly lower technical success rate was seen for the first five cases of each radiologist than for subsequent cases (25/30 = 83.3% versus 366/384 = 95.3%, p < 0.02) and for the first 20 cases than for subsequent cases (90/100 = 90% versus 284/296 = 95.9%, p < 0.05). For 11-gauge vacuum-assisted biopsy, a significantly lower technical success rate was seen for the first five cases than for subsequent cases (17/20 = 85.0% versus 310/322 = 96.3%, p < 0.05) and for the first 15 cases than for subsequent cases (54/60 = 90.0% versus 273/283 = 96.5%, p = 0.03). The false-negative rate was higher for the first 15 cases compared with subsequent cases both for stereotactic 14-gauge automated core biopsy (4/31 = 12.9% versus 3/115 = 2.6%, p < 0.04) and for stereotactic 11-gauge vacuum-assisted biopsy (2/27 = 7.4% versus 0/85 = 0%, p < 0.06).
CONCLUSION: A learning curve exists for stereotactic breast biopsy. Significantly higher technical success rates and lower false-negative rates were observed after the first five to 20 cases for 14-gauge automated core biopsy and after the first five to 15 cases for 11-gauge vacuum-assisted biopsy. Even after a radiologist has experience with stereotactic biopsy, changes in equipment may result in a new learning curve.

Mesh:

Year:  2001        PMID: 11222213     DOI: 10.2214/ajr.176.3.1760721

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

1.  Vacuum-assisted biopsies under MR guidance: results of 72 procedures.

Authors:  C Malhaire; C El Khoury; F Thibault; A Athanasiou; P Petrow; L Ollivier; A Tardivon
Journal:  Eur Radiol       Date:  2010-01-30       Impact factor: 5.315

2.  Structured ultrasonography workshop for breast surgeons: is it an effective training tool?

Authors:  Michael T Law; Ian C Bennett
Journal:  World J Surg       Date:  2010-03       Impact factor: 3.352

3.  Values of pathological analysis of lost tissue fragments in the vacuum canister during a vacuum-assisted stereotactic biopsy of the breast.

Authors:  M El Khoury; B Mesurolle; A Omeroglu; A Aldis; E Kao
Journal:  Br J Radiol       Date:  2013-03-21       Impact factor: 3.039

4.  Is there a July phenomenon? The effect of July admission on intensive care mortality and length of stay in teaching hospitals.

Authors:  William A Barry; Gary E Rosenthal
Journal:  J Gen Intern Med       Date:  2003-08       Impact factor: 5.128

5.  Fluorescence spectroscopy: an adjunct diagnostic tool to image-guided core needle biopsy of the breast.

Authors:  Changfang Zhu; Elizabeth S Burnside; Gale A Sisney; Lonie R Salkowski; Josephine M Harter; Bing Yu; Nirmala Ramanujam
Journal:  IEEE Trans Biomed Eng       Date:  2009-03-04       Impact factor: 4.538

Review 6.  Guidelines from the European Society of Breast Imaging for diagnostic interventional breast procedures.

Authors:  Matthew Wallis; Anne Tardivon; Anne Tarvidon; Thomas Helbich; Ingrid Schreer
Journal:  Eur Radiol       Date:  2007-02       Impact factor: 7.034

7.  Economically affordable anatomical kidney phantom with calyxes for puncture and drainage training in interventional urology and radiology.

Authors:  Asko Ristolainen; Peeter Ross; Juri Gavšin; Eero Semjonov; Maarja Kruusmaa
Journal:  Acta Radiol Short Rep       Date:  2014-06-13

8.  Augmented Reality Guided Needle Biopsy of Soft Tissue: A Pilot Study.

Authors:  David Asgar-Deen; Jay Carriere; Ericka Wiebe; Lashan Peiris; Aalo Duha; Mahdi Tavakoli
Journal:  Front Robot AI       Date:  2020-06-16

9.  Fabrication of Low-cost Realistic Three-dimensional Static Kidney Phantom for Ultrasound-guided Biopsy Applications.

Authors:  Firas Fohely; Ammar A Oglat; Khaled Sabarna; Zakaria Shweiki; Bayan Hamoudeh; Rulin Shalaan
Journal:  J Med Ultrasound       Date:  2021-12-27

10.  Stereotactic core-needle biopsy of non-mass calcifications: outcome and accuracy at long-term follow-up.

Authors:  Boo-Kyung Han; Yeon Hyeon Choe; Young-Hyeh Ko; Seok-Jin Nam; Jung-Han Kim; Jung-Hyun Yang
Journal:  Korean J Radiol       Date:  2003 Oct-Dec       Impact factor: 3.500

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.