Literature DB >> 11218489

Retrospective clinical study and survival analysis on partial ceramic crowns: results up to 7 years.

A Felden1, G Schmalz, K A Hiller.   

Abstract

The purpose of the present study was to determine retrospectively the clinical performance of 42 all-ceramic partial crowns (PCCs) placed during the past 7 years. All patients (n = 25) with partial ceramic crowns (n = 49) placed by one experienced dentist between 1992 and 1999 were asked to take part in a clinical study, and 22 patients with 42 restorations agreed to do so. All partial ceramic crowns studied were fabricated using the IPS-Empress I all-ceramic system (Vivadent). The following luting composites were used for placing the restorations: 20 (47.6%) Variolink high viscosity (Vivadent), 3 (7.1%) Variolink ultra (Vivadent), 17 (40.5%) Dual Zement (Vivadent), and 2 (4.8%) Compolute (Espe). The partial ceramic crowns were examined clinically using the modified USPHS criteria. Of the 42 restorations, 40 (95.2%) were still in function without any need of replacement. One restoration (2.4%) had failed before starting the clinical study, and another one (2.4%) fractured during the study. Twenty-eight (66.7%) of the partial ceramic crowns evaluated were rated Alpha with respect to marginal adaptation. Twelve (28.6%) restorations were rated Bravo, no Charlie ratings were found and 2 (4.7%) restorations were rated Delta. The Kaplan-Meier analysis was used to calculate the survival rate. The probability of survival (95% confidence interval) for 7 years was 81% (66-96%). These data indicate that partial ceramic crowns may provide successful esthetic restorations in posterior teeth.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11218489     DOI: 10.1007/s007840000082

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  13 in total

1.  Partial ceramic crowns. Influence of preparation design and luting material on margin integrity--a scanning electron microscopic study.

Authors:  Marianne Federlin; C Sipos; K-A Hiller; B Thonemann; G Schmalz
Journal:  Clin Oral Investig       Date:  2004-08-10       Impact factor: 3.573

2.  Seven-year clinical performance of CEREC-2 all-ceramic CAD/CAM restorations placed within deeply destroyed teeth.

Authors:  Matthias J Roggendorf; Bianka Kunzi; Johannes Ebert; Hubert C Roggendorf; Roland Frankenberger; Sven M Reich
Journal:  Clin Oral Investig       Date:  2011-12-07       Impact factor: 3.573

3.  Statistical failure analysis of adhesive resin cement bonded dental ceramics.

Authors:  Yaou Wang; Noriko Katsube; Robert R Seghi; Stanislav I Rokhlin
Journal:  Eng Fract Mech       Date:  2007-08       Impact factor: 4.406

4.  Controlled, prospective, randomized, clinical split-mouth evaluation of partial ceramic crowns luted with a new, universal adhesive system/resin cement: results after 18 months.

Authors:  Vanessa Vogl; Karl-Anton Hiller; Wolfgang Buchalla; Marianne Federlin; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2016-03-12       Impact factor: 3.573

5.  Two-year clinical performance of cast gold vs ceramic partial crowns.

Authors:  Marianne Federlin; Tobias Männer; Karl-Anton Hiller; Sebastian Schmidt; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2006-04-14       Impact factor: 3.573

6.  Long-term clinical performance and longevity of gold alloy vs ceramic partial crowns.

Authors:  J Wagner; K-A Hiller; G Schmalz
Journal:  Clin Oral Investig       Date:  2003-05-13       Impact factor: 3.573

7.  Three-year clinical performance of cast gold vs ceramic partial crowns.

Authors:  M Federlin; J Wagner; T Männer; K-A Hiller; G Schmalz
Journal:  Clin Oral Investig       Date:  2007-11-01       Impact factor: 3.573

8.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379

9.  Marginal integrity of CAD/CAM fixed partial dentures.

Authors:  Martin Rosentritt; Michael Behr; Carola Kolbeck; Gerhard Handel
Journal:  Eur J Dent       Date:  2007-01

10.  Short fiber reinforced composite: a new alternative for direct onlay restorations.

Authors:  Sufyan Garoushi; Enas Mangoush; Mangoush Vallittu; Lippo Lassila
Journal:  Open Dent J       Date:  2013-12-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.