Literature DB >> 11202872

Rationale for the use of low-torque endodontic motors in root canal instrumentation.

G Gambarini1.   

Abstract

Fracture of nickel-titanium rotary files is an iatrogenic error which can seriously jeopardize root canal therapy. If a high-torque motor is used, the instrument-specific limit-torque (fracture limit) is often exceeded, thus increasing the risk of intracanal failure. A possible solution to this problem is to use a low-torque endodontic motor which operates below these values. If the torque is set just below the limit of elasticity for each instrument, the risk of fracture is likely to be markedly reduced. The purpose of this paper was to discuss mechanical properties of NiTi rotary instruments, the rationale for selecting low torque values, and to use clinically a new endodontic motor (step-motor) which operates below the limit of elasticity of each rotary file. The step-motor was found to be helpful in reducing the risk of instrument fracture. Irreversible material damage (plastic deformation) and instrument fracture were rarely seen. Low-torque instrumentation also increased tactile sense and, consequently, mental awareness of rotary instrumentation.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11202872     DOI: 10.1034/j.1600-9657.2000.016003095.x

Source DB:  PubMed          Journal:  Endod Dent Traumatol        ISSN: 0109-2502


  8 in total

1.  Evaluation of deformation and fracture rates for nickel-titanium rotary instruments according to the frequency of clinical use.

Authors:  Ayça Yılmaz; Sıtkı Selçuk Gökyay; Rüştü Dağlaroğlu; Işıl Karagöz Küçükay
Journal:  Eur Oral Res       Date:  2018-05-01

2.  Root canal shaping of curved canals by Reciproc Blue system and Pro Taper Gold: A micro-computed tomographic study.

Authors:  Rogério-Vieira Silva; Murilo-Priori Alcalde; Martinho-Campolina-Ribeiro Horta; Clarissa-Teles Rodrigues; Frank-Ferreira Silveira; Marco-Antônio Duarte; Eduardo Nunes
Journal:  J Clin Exp Dent       Date:  2021-02-01

3.  Ex-Vivo Comparison of Torsional Stress on Nickel-Titanium Instruments Activated by Continuous Rotation or Adaptive Motion.

Authors:  Joo Yeong Lee; Sang Won Kwak; Jung-Hong Ha; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2020-04-17       Impact factor: 3.623

4.  Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments.

Authors:  Gianluca Gambarini; Gabriele Miccoli; Marco Seracchiani; Tatyana Khrenova; Orlando Donfrancesco; Maurilio D'Angelo; Massimo Galli; Dario Di Nardo; Luca Testarelli
Journal:  Materials (Basel)       Date:  2019-08-08       Impact factor: 3.623

5.  Effects of wobbling angle on the stability measures of orthodontic mini-implants during insertion and removal procedures.

Authors:  Il-Sik Cho; Sang-Ho Baek; Young Ho Kim
Journal:  Angle Orthod       Date:  2013-05-10       Impact factor: 2.079

6.  Comparison of success rates of orthodontic mini-screws by the insertion method.

Authors:  Jung Suk Kim; Seong Hwan Choi; Sang Kwon Cha; Jang Han Kim; Hwa Jin Lee; Sang Seon Yeom; Chung Ju Hwang
Journal:  Korean J Orthod       Date:  2012-10-29       Impact factor: 1.372

Review 7.  Torque Generation of the Endodontic Instruments: A Narrative Review.

Authors:  Sang Won Kwak; Ya Shen; He Liu; Hyeon-Cheol Kim; Markus Haapasalo
Journal:  Materials (Basel)       Date:  2022-01-17       Impact factor: 3.623

8.  Evaluation of Cyclic Fatigue of Hyflex EDM, Twisted Files, and ProTaper Gold Manufactured with Different Processes: An In Vitro Study.

Authors:  Pooja D Khandagale; Prashant P Shetty; Saleem D Makandar; Pradeep A Bapna; Mohmed Isaqali Karobari; Anand Marya; Pietro Messina; Giuseppe Alessandro Scardina
Journal:  Int J Dent       Date:  2021-07-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.