Is all ventricular fibrillation the same? Influence of mode of induction on characteristics of ventricular fibrillation.

T Taneja1, J Goldberger, D Johnson, A Kadish.   

Abstract

INTRODUCTION: Little information is available on the relationship between the mode of induction of ventricular fibrillation (VF) to VF characteristics. METHODS AND
RESULTS: VF was induced from the anterior left ventricle by programmed electrical stimulation, burst pacing, alternating current (AC), high current S2 at a site remote from S1, T wave shock, and intersecting wavefronts in seven normal dogs and seven dogs with chronic myocardial infarction. Using two electrode arrays, 112 electrograms were recorded from the anterior and lateral wall. Cycle lengths were analyzed and activation vectors were created by summing orthogonally recorded bipolar electrograms. The magnitude of the vector loops was integrated over time to produce an "ensemble vector" index (EVI) whose magnitude is high when beat-to-beat activation direction is consistent and low when activation direction is variable. T wave shock-induced VF had a significantly longer cycle length 1 to 5 seconds after VF onset than other modes of induction (P < 0.05). The frequency-corrected EVI was significantly larger for AC current and T wave shock-induced VF as opposed to all other modes of VF induction in early VF (P < 0.0001). After 10 seconds of VF, these differences persisted only on the anterior wall.
CONCLUSION: VF induced in animals by T wave shock and AC current had different characteristics than VF induced by other methods. These findings may have implications for our understanding of VF pathophysiology.

Entities:  

Mesh:

Year:  2000        PMID: 11196559     DOI: 10.1046/j.1540-8167.2000.01355.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  4 in total

1.  [Is intraoperative ICD-testing still necessary?].

Authors:  C Mewis; H-R Neuberger; A Buob
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-06

2.  Shock or no shock - a question of philosophy or should intraoperative implantable cardioverter defibrillator testing be recommended?

Authors:  Andreas Keyser; Michael K Hilker; Sebastian Schmidt; Christian von Bary; Wolfgang Zink; Michael Ried; Christof Schmid; Claudius Diez
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-12-07

3.  Induction by direct current pulse versus 50-Hz pacing on ventricular fibrillation and defibrillation.

Authors:  Hoong Sern Lim; Sharon Flannigan; Howard Marshall
Journal:  J Interv Card Electrophysiol       Date:  2010-05-12       Impact factor: 1.900

4.  Left ventricular dysfunction is associated with prolonged average ventricular fibrillation cycle length in patients with implantable cardioverter defibrillators.

Authors:  Guilherme Fenelon; Bruce S Stambler; Etienne Huvelle; Pedro Brugada; William G Stevenson
Journal:  J Interv Card Electrophysiol       Date:  2002-12       Impact factor: 1.900