Direct strain estimation in elastography using spectral cross-correlation.

T Varghese1, E E Konofagou, J Ophir, S K Alam, M Bilgen.   

Abstract

Spectral estimation of tissue strain has been performed previously by using the centroid shift of the power spectrum or by estimating the variation in the mean scatterer spacing in the spectral domain. The centroid shift method illustrates the robustness of the direct, incoherent strain estimator. In this paper, we present a strain estimator that uses spectral cross-correlation of the pre- and postcompression power spectrum. The centroid shift estimator estimates strain from the mean center frequency shift, while the spectral cross-correlation estimates the shift over the entire spectrum. Spectral cross-correlation is shown to be more sensitive to small shifts in the power spectrum and, thus, provides better estimation for smaller strains when compared to the spectral centroid shift. Spectral cross-correlation shares all the advantages gained using the spectral centroid shift, in addition to providing accurate and precise strain estimation for small strains. The variance and noise properties of the spectral strain estimators quantified by their respective strain filters are also presented.

Mesh:

Year:  2000        PMID: 11179627     DOI: 10.1016/s0301-5629(00)00316-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

Review 1.  Medical ultrasound: imaging of soft tissue strain and elasticity.

Authors:  Peter N T Wells; Hai-Dong Liang
Journal:  J R Soc Interface       Date:  2011-06-16       Impact factor: 4.118

2.  Signal to noise ratio comparisons for ultrasound attenuation slope estimation algorithms.

Authors:  Eenas A Omari; Tomy Varghese
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

3.  Shear modulus reconstruction by ultrasonically measured strain ratio.

Authors:  Chikayoshi Sumi; Hidenori Matsuzawa
Journal:  J Med Ultrason (2001)       Date:  2007-12-14       Impact factor: 1.314

4.  Ultrasound Elastography for Estimation of Regional Strain of Multilayered Hydrogels and Tissue-Engineered Cartilage.

Authors:  Chen-Yuan Chung; Joseph Heebner; Harihara Baskaran; Jean F Welter; Joseph M Mansour
Journal:  Ann Biomed Eng       Date:  2015-06-16       Impact factor: 3.934

5.  Bayesian regularization applied to ultrasound strain imaging.

Authors:  Matthew McCormick; Nicholas Rubert; Tomy Varghese
Journal:  IEEE Trans Biomed Eng       Date:  2011-01-17       Impact factor: 4.538

6.  Quasi-Static Ultrasound Elastography.

Authors:  Tomy Varghese
Journal:  Ultrasound Clin       Date:  2009-07

Review 7.  Application of Elastography for the Noninvasive Assessment of Biomechanics in Engineered Biomaterials and Tissues.

Authors:  Woong Kim; Virginia L Ferguson; Mark Borden; Corey P Neu
Journal:  Ann Biomed Eng       Date:  2016-01-20       Impact factor: 3.934

8.  GPU Accelerated Multilevel Lagrangian Carotid Strain Imaging.

Authors:  Nirvedh H Meshram; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-05-28       Impact factor: 2.725

9.  Spatially variant regularization for tissue strain measurement and shear modulus reconstruction.

Authors:  Chikayoshi Sumi
Journal:  J Med Ultrason (2001)       Date:  2007-09-14       Impact factor: 1.878